Literature DB >> 18565688

Conformity of LINAC-based stereotactic radiosurgery using dynamic conformal arcs and micro-multileaf collimator.

Lisa J Hazard1, Brian Wang, Thomas B Skidmore, Shyh-Shi Chern, Bill J Salter, Randy L Jensen, Dennis C Shrieve.   

Abstract

PURPOSE: To assess the conformity of dynamic conformal arc linear accelerator-based stereotactic radiosurgery and to describe a standardized method of isodose surface (IDS) selection. METHODS AND MATERIALS: In 174 targets, the conformity index (CI) at the prescription IDS used for treatment was calculated as CI = (PIV/PVTV)/(PVTV/TV), where TV is the target volume, PIV (prescription isodose volume) is the total volume encompassed by the prescription IDS, and PVTV is the TV encompassed by the IDS. In addition, a "standardized" prescription IDS (sIDS) was chosen according to the following criteria: 95% of the TV was encompassed by the PIV and 99% of TV was covered by 95% of the prescription dose. The CIs at the sIDS were also calculated.
RESULTS: The median CI at the prescription IDS and sIDS was 1.63 and 1.47, respectively (p < 0.001). In 132 of 174 cases, the volume of normal tissue in the PIV was reduced by the prescription to the sIDS compared with the prescription IDS, in 20 cases it remained unchanged, and in 22 cases it was increased.
CONCLUSION: The CIs obtained with linear accelerator-based stereotactic radiosurgery are comparable to those previously reported for gamma knife stereotactic radiosurgery. Using a uniform method to select the sIDS, adequate target coverage was usually achievable with prescription to an IDS greater than that chosen by the treating physician (prescription IDS), providing sparing of normal tissue. Thus, the sIDS might aid physicians in identifying a prescription IDS that balances coverage and conformity.

Mesh:

Year:  2008        PMID: 18565688     DOI: 10.1016/j.ijrobp.2008.04.026

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  23 in total

1.  Consideration of optimal isodose surface selection for target coverage in micro-multileaf collimator-based stereotactic radiotherapy for large cystic brain metastases: comparison of 90%, 80% and 70% isodose surface-based planning.

Authors:  K Ohtakara; S Hayashi; H Tanaka; H Hoshi
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

2.  Dosimetric comparison of 2.5 mm vs. 3.0 mm leaf width micro-multileaf collimator-based treatment systems for intracranial stereotactic radiosurgery using dynamic conformal arcs: implications for treatment planning.

Authors:  Kazuhiro Ohtakara; Shinya Hayashi; Hidekazu Tanaka; Hiroaki Hoshi
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

3.  Characterisation of dose distribution in linear accelerator-based intracranial stereotactic radiosurgery with the dynamic conformal arc technique: consideration of the optimal method for dose prescription and evaluation.

Authors:  K Ohtakara; S Hayashi; H Hoshi
Journal:  Br J Radiol       Date:  2011-02-22       Impact factor: 3.039

4.  The relation between various conformity indices and the influence of the target coverage difference in prescription isodose surface on these values in intracranial stereotactic radiosurgery.

Authors:  K Ohtakara; S Hayashi; H Hoshi
Journal:  Br J Radiol       Date:  2011-09-21       Impact factor: 3.039

5.  A feasibility dosimetric study on prostate cancer : are we ready for a multicenter clinical trial on SBRT?

Authors:  Carmelo Marino; Elena Villaggi; Giulia Maggi; Marco Esposito; Lidia Strigari; Elisa Bonanno; Giusi R Borzì; Claudia Carbonini; Rita Consorti; David Fedele; Christian Fiandra; Isidora Ielo; Tiziana Malatesta; Maria Rosa Malisan; Anna Martinotti; Renzo Moretti; Barbara Nardiello; Caterina Oliviero; Stefania Clemente; Pietro Mancosu
Journal:  Strahlenther Onkol       Date:  2015-03-08       Impact factor: 3.621

6.  The effect of setup uncertainty on optimal dosimetric margin in LINAC-based stereotactic radiosurgery with dynamic conformal arc technique.

Authors:  Xiaoyu Duan; William Giles; John P Kirkpatrick; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2019

7.  The effect of MLC leaf width in single-isocenter multi-target radiosurgery with volumetric modulated arc therapy.

Authors:  Zhanerke Abisheva; Scott R Floyd; Joseph K Salama; John Kirkpatrick; Fang-Fang Yin; Michael J Moravan; William Giles; Justus Adamson
Journal:  J Radiosurg SBRT       Date:  2019

8.  Stereotactic radiosurgery for a single brain metastasis: factors impacting control.

Authors:  Aaron E Wagner; Andy Chen; Christopher J Anker; Jonathan D Tward; Amol J Ghia; Randy L Jensen; Dennis C Shrieve
Journal:  J Radiosurg SBRT       Date:  2014

9.  Tumor control and incidence of radiation necrosis after reirradiation with stereotactic radiosurgery for brain metastases.

Authors:  Breanne E Terakedis; Randy L Jensen; Kenneth Boucher; Dennis C Shrieve
Journal:  J Radiosurg SBRT       Date:  2014

10.  Prescription to 50-75% isodose line may be optimum for linear accelerator based radiosurgery of cranial lesions.

Authors:  Bo Zhao; Jian-Yue Jin; Ning Wen; Yimei Huang; M Salim Siddiqui; Indrin J Chetty; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2014
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.