Literature DB >> 18562753

Unenhanced MR angiography of the renal arteries with balanced steady-state free precession dixon method.

Randall B Stafford1, Mohammad Sabati, Michael J Haakstad, Houman Mahallati, Richard Frayne.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the feasibility of a novel technique for fat-water separation to image the renal arteries without using a contrast agent.
CONCLUSION: Five healthy volunteers were imaged on a 3-T clinical MR scanner using the balanced steady-state free precession (SSFP) Dixon method. We were able to image the proximal renal arteries with high conspicuity within a 3-minute overall scanning time. The balanced-SSFP Dixon method shows potential for unenhanced MR angiography of the proximal renal arteries.

Entities:  

Mesh:

Year:  2008        PMID: 18562753     DOI: 10.2214/AJR.07.3076

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Non-contrast renal MRA using multi-shot gradient echo EPI at 3-T MRI.

Authors:  Kosuke Morita; Takeshi Nakaura; Masami Yoneyama; Yasunori Nagayama; Masafumi Kidoh; Hiroyuki Uetani; Osamu Ikeda; Yasuyuki Yamashita; Toshinori Hirai
Journal:  Eur Radiol       Date:  2021-01-21       Impact factor: 5.315

2.  A 3D balanced-SSFP Dixon technique with group-encoded k-space segmentation for breath-held non-contrast-enhanced MR angiography.

Authors:  Manojkumar Saranathan; Ersin Bayram; Pauline W Worters; James F Glockner
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

3.  Inversion-recovery-prepared dixon bSSFP: initial clinical experience with a novel pulse sequence for renal MRA within a breathhold.

Authors:  Pauline W Worters; Manojkumar Saranathan; Alan Xu; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2011-11-16       Impact factor: 4.813

4.  Quadruple inversion-recovery b-SSFP MRA of the abdomen: initial clinical validation.

Authors:  Iliyana P Atanasova; Ruth P Lim; Hersh Chandarana; Pippa Storey; Mary T Bruno; Daniel Kim; Vivian S Lee
Journal:  Eur J Radiol       Date:  2014-06-02       Impact factor: 3.528

Review 5.  REACT - A novel flow-independent non-gated non-contrast MR angiography technique using magnetization-prepared 3D non-balanced dual-echo dixon method: Preliminary clinical experience.

Authors:  Eu Jin Tan; Shuo Zhang; Prasanna Tirukonda; Le Roy Chong
Journal:  Eur J Radiol Open       Date:  2020-06-07

6.  Non-contrast mDixon MR angiography of the neck: Comparison with time-of-flight MR angiography in normal subjects.

Authors:  Tomohiro Mizoshiri; Morikatsu Yoshida; Seitaro Oda; Shota Tsumagari; Takeshi Nakaura; Kazunori Harada; Osamu Ikeda
Journal:  Medicine (Baltimore)       Date:  2021-12-23       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.