Literature DB >> 18555647

Total hip arthroplasty with a collarless, tapered, fiber metal proximally coated femoral stem: minimum 5-year follow-up.

Gregg R Klein1, Harlan B Levine, Susan C Nafash, Helena C Lamothe, Mark A Hartzband.   

Abstract

The purpose of this study was to evaluate the midterm results, osteointegration potential, and implant-related complications of a cementless, collarless, proximally coated, distally tapered femoral hip prosthesis. The clinical and radiographic results for 129 hips in 116 patients after total hip arthroplasty with a Fiber Metal Taper (Zimmer, Inc ,Warsaw, Ind) femoral stem are reported. One hundred twenty-two (95%) hips were available for the minimum of 5 years clinical and radiographic follow-up. The mean duration of follow-up was 81 months (range, 60-104 months). The mean Harris hip score improved from 44 to 92 at the most recent follow-up. All femoral components were clinically stable with radiographic evidence of bone ingrowth. There has been no evidence of subsidence greater than 2 mm, no significant thigh pain, and no femoral revisions for any reason. Total hip arthroplasty with the Fiber Metal Taper stem demonstrates good clinical and radiographic results at midterm follow-up.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18555647     DOI: 10.1016/j.arth.2008.04.010

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Periprosthetic fractures may be more likely in cementless femoral stems with sharp edges.

Authors:  K Hu; X Zhang; J Zhu; C Wang; W Ji; X Bai
Journal:  Ir J Med Sci       Date:  2009-10-22       Impact factor: 1.568

2.  A concise minimum eight year follow-up of proximally porous-coated tapered titanium femoral stem in primary total hip arthroplasty.

Authors:  Benjamin Beecher; Philip Glassner; Henrik Malchau; Young-Min Kwon
Journal:  Int Orthop       Date:  2012-03-14       Impact factor: 3.075

3.  Impact of stem profile on the revisability and the need for osteotomy in well-fixed cemented revision total knee arthroplasty implants.

Authors:  Alexander Maslaris; Georgios Spyrou; Carsten Schoeneberg; Mustafa Citak; Georg Matziolis
Journal:  Arch Orthop Trauma Surg       Date:  2022-08-05       Impact factor: 2.928

4.  An initial experience with hip resurfacing versus cementless total hip arthroplasty.

Authors:  Justin Michael Arndt; Glenn D Wera; Victor M Goldberg
Journal:  HSS J       Date:  2013-06-25

5.  Excessive distal migration of fiber-mesh coated femoral stems.

Authors:  Thomas Baad-Hansen; Søren Kold; Niels Olsen; Finn Christensen; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-04-19       Impact factor: 3.717

6.  Long-term follow-up results of a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels.

Authors:  Chang Wook Han; Ick Hwan Yang; Hye Yeon Lee; Chang Dong Han
Journal:  Yonsei Med J       Date:  2012-01       Impact factor: 2.759

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.