Literature DB >> 18549844

Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial).

Marco A Costa1, Dominick J Angiolillo, Mark Tannenbaum, Mitchell Driesman, Alan Chu, John Patterson, William Kuehl, Joseph Battaglia, Samir Dabbons, Fayez Shamoon, Bruce Flieshman, Alan Niederman, Theodore A Bass.   

Abstract

Drug-eluting stent failures were associated with various clinical factors. However, the clinical impact of stent deployment technique was unknown. This study was designed to evaluate the frequency and impact of suboptimal percutaneous coronary intervention on long-term outcomes of 1,557 patients treated with sirolimus-eluting stents (SESs) in 41 US hospitals. All steps of the interventional procedure were scrutinized by an independent core laboratory to determine the occurrence of geographic miss (GM). GM included longitudinal (LGM; injured or diseased segment not covered by SES) or axial GM (balloon-artery size ratio <0.9 or >1.3) mismatches. Patients with and without GM were stratified (GM vs no-GM group). Patients, investigators, and the independent clinical event adjudication committee were blind to study group assignments. The primary end point was 1-year target-vessel revascularization (TVR) rate. Incidences and predictors of GM and safety outcomes were secondary end points. GM occurred in 943 patients (66.5%): 47.6% had LGM, 35.2% had axial GM, and 16.5% had both. One-year TVR rates were 5.1% in the GM group versus 2.5% in the no-GM group (p=0.025). TVR was 6.1% in the LGM versus 2.6% in the no-LGM subgroups (p=0.001). The association of GM with 1-year TVR was independent of clinical or anatomic factors (hazard ratio 2.0, 95% confidence interval 1.0 to 4.02, p=0.05). There was a 3-fold increase in myocardial infarction rates associated with GM (2.4% vs 0.8%; p=0.04). In conclusion, GM occurred frequently during SES implantation and was associated with increased risk of TVR and myocardial infarction at 1 year. These results emphasized the need for improvement in contemporary percutaneous coronary intervention practices and technologies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18549844     DOI: 10.1016/j.amjcard.2008.02.053

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  33 in total

1.  Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Deepak L Bhatt; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2013-05-30

Review 2.  QCA, IVUS and OCT in interventional cardiology in 2011.

Authors:  Johan H C Reiber; Shengxian Tu; Joan C Tuinenburg; Gerhard Koning; Johannes P Janssen; Jouke Dijkstra
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

Review 3.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

Review 4.  Mechanisms of drug-eluting stent restenosis.

Authors:  Jiro Aoki; Kengo Tanabe
Journal:  Cardiovasc Interv Ther       Date:  2020-11-21

5.  Impact of Intravascular Ultrasound in Clinical Practice.

Authors:  Andres Vasquez; Neville Mistry; Jasvindar Singh
Journal:  Interv Cardiol       Date:  2014-08

Review 6.  Cath Lab Robotics: Paradigm Change in Interventional Cardiology?

Authors:  Zachary K Wegermann; Rajesh V Swaminathan; Sunil V Rao
Journal:  Curr Cardiol Rep       Date:  2019-08-31       Impact factor: 2.931

7.  Post-dilatation after implantation of bioresorbable everolimus- and novolimus-eluting scaffolds: an observational optical coherence tomography study of acute mechanical effects.

Authors:  Florian Blachutzik; Niklas Boeder; Jens Wiebe; Alessio Mattesini; Oliver Dörr; Astrid Most; Timm Bauer; Jens Röther; Monique Tröbs; Christian Schlundt; Stephan Achenbach; Christian W Hamm; Holger M Nef
Journal:  Clin Res Cardiol       Date:  2016-10-18       Impact factor: 5.460

Review 8.  Robotic-assisted angioplasty: current status and future possibilities.

Authors:  Nathaniel R Smilowitz; Giora Weisz
Journal:  Curr Cardiol Rep       Date:  2012-10       Impact factor: 2.931

9.  Late thrombosis of sirolimus-eluting stent: a multifactorial problem.

Authors:  Igor Kranjec; Andreja Cerne
Journal:  Case Rep Med       Date:  2009-11-04

10.  Effect of clopidogrel discontinuation at 1 year after drug eluting stent placement on soluble CD40L, P-selectin and C-reactive protein levels: DECADES (Discontinuation Effect of Clopidogrel After Drug Eluting Stent): a multicenter, open-label study.

Authors:  Joanna J Wykrzykowska; Ascan Warnholtz; Peter de Jaeger; Nick Curzen; Keith G Oldroyd; Jean Philippe Collet; Jurrien M Ten Berg; Tessa Rademaker; Dick Goedhart; Jurgen Lissens; Peter-Paul Kint; Patrick W Serruys
Journal:  J Thromb Thrombolysis       Date:  2009-11       Impact factor: 2.300

View more