Literature DB >> 18548960

Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs.

Margareta K Molin1, Stig L Karlsson.   

Abstract

PURPOSE: The aim of this prospective study was to evaluate the clinical performance of fully sintered hot isostatic pressed yttria-partially-stabilized zirconia (Denzir) 3-unit fixed partial dentures (FPDs).
MATERIALS AND METHODS: Nineteen 3-unit FPDs were placed in 18 patients. Ten FPDs were placed in the maxilla and 9 in the mandible. Two calibrated examiners evaluated the FPDs independently 1 week (baseline), 1 year, 3 years, and 5 years after placement using the California Dental Association quality evaluation system.
RESULTS: All FPDs were intact at the 5-year examination. One FPD lost retention after 12 months but remained intact; it was recemented and is still in function after 5 years. All FPDs were rated satisfactory over 5 years. No changes were seen in terms of color and anatomic form. The number of slightly rough or pitted occlusal surfaces increased approximately 30% over 5 years. Visible evidence of ditching along the margin increased over time, but only for those FPDs luted with zinc phosphate cement.
CONCLUSION: The 5-year results indicate that yttria-partially-stabilized zirconia 3-unit FPDs with anatomically designed frameworks are promising prosthetic alternatives, even in the premolar and molar regions. However, for all-ceramic FPDs with more units in function, further studies are necessary.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18548960

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  52 in total

1.  Shear bond strength between an indirect composite layering material and feldspathic porcelain-coated zirconia ceramics.

Authors:  Ryosuke Fushiki; Futoshi Komine; Markus B Blatz; Mai Koizuka; Kohei Taguchi; Hideo Matsumura
Journal:  Clin Oral Investig       Date:  2011-12-06       Impact factor: 3.573

2.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

3.  Modified Y-TZP core design improves all-ceramic crown reliability.

Authors:  N R F A Silva; E A Bonfante; B T Rafferty; R A Zavanelli; E D Rekow; V P Thompson; P G Coelho
Journal:  J Dent Res       Date:  2010-11-05       Impact factor: 6.116

4.  Overview: Damage resistance of graded ceramic restorative materials.

Authors:  Yu Zhang
Journal:  J Eur Ceram Soc       Date:  2012-08-01       Impact factor: 5.302

5.  Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result.

Authors:  Florian Beuer; Caroline Sachs; Julian Groesser; Jan-Frederik Gueth; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2015-09-24       Impact factor: 3.573

6.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

7.  Sliding contact fatigue of graded zirconia with external esthetic glass.

Authors:  L Ren; M N Janal; Y Zhang
Journal:  J Dent Res       Date:  2011-06-10       Impact factor: 6.116

Review 8.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

9.  Clinical outcomes of zirconia-based implant- and tooth-supported single crowns.

Authors:  Farahnaz Nejatidanesh; Hedayat Moradpoor; Omid Savabi
Journal:  Clin Oral Investig       Date:  2015-04-25       Impact factor: 3.573

10.  Fracture resistance and failure mode of posterior fixed dental prostheses fabricated with two zirconia CAD/CAM systems.

Authors:  Carlos López-Suárez; Esther Gonzalo; Jesús Peláez; Verónica Rodríguez; María-Jesús Suárez
Journal:  J Clin Exp Dent       Date:  2015-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.