Literature DB >> 18541493

A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories.

Michael Lustig1, Seung-Jean Kim, John M Pauly.   

Abstract

A fast and simple algorithm for designing time-optimal waveforms is presented. The algorithm accepts a given arbitrary multidimensional k-space trajectory as the input and outputs the time-optimal gradient waveform that traverses k-space along that path in minimum time. The algorithm is noniterative, and its run time is independent of the complexity of the curve, i.e., the number of switches between slew-rate limited acceleration, slew-rate limited deceleration, and gradient amplitude limited regions. The key in the method is that the gradient amplitude is designed as a function of arc length along the k-space trajectory, rather than as a function of time. Several trajectory design examples are presented.

Mesh:

Year:  2008        PMID: 18541493      PMCID: PMC2928662          DOI: 10.1109/TMI.2008.922699

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  15 in total

1.  Simple analytic spiral K-space algorithm.

Authors:  G H Glover
Journal:  Magn Reson Med       Date:  1999-08       Impact factor: 4.668

2.  Time-optimal multidimensional gradient waveform design for rapid imaging.

Authors:  Brian A Hargreaves; Dwight G Nishimura; Steven M Conolly
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Simple analytic variable density spiral design.

Authors:  Dong-hyun Kim; Elfar Adalsteinsson; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

4.  Fast spiral coronary artery imaging.

Authors:  C H Meyer; B S Hu; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

5.  Fast three-dimensional k-space trajectory design using missile guidance ideas.

Authors:  Roberto Mir; Andres Guesalaga; Juan Spiniak; Marcelo Guarini; Pablo Irarrazaval
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

6.  Auto-calibrated parallel spiral imaging.

Authors:  Keith Heberlein; Xiaoping Hu
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

7.  An optimal design method for magnetic resonance imaging gradient waveforms.

Authors:  O P Simonetti; J L Duerk; V Chankong
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

8.  Frequency resolved single-shot MR imaging using stochastic k-space trajectories.

Authors:  K Scheffler; J Hennig
Journal:  Magn Reson Med       Date:  1996-04       Impact factor: 4.668

Review 9.  Multishot rosette trajectories for spectrally selective MR imaging.

Authors:  D C Noll
Journal:  IEEE Trans Med Imaging       Date:  1997-08       Impact factor: 10.048

10.  Magnetic resonance fluoroscopy using spirals with variable sampling densities.

Authors:  D M Spielman; J M Pauly; C H Meyer
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

View more
  28 in total

1.  Multiple-Input Multiple-Output (MIMO) MRI: Combining Parallel Excitation and Parallel Reception for Enhanced Imaging.

Authors:  Xianglun Mao; Nicole L Vike; Thomas M Talavage; Joseph V Rispoli; David J Love
Journal:  IEEE Trans Comput Imaging       Date:  2019-03-13

2.  Slice profile effects on nCPMG SS-FSE.

Authors:  Eric K Gibbons; Patrick Le Roux; John M Pauly; Adam B Kerr
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

3.  Partial fourier shells trajectory for non-cartesian MRI.

Authors:  Shengzhen Tao; Yunhong Shu; Joshua D Trzasko; John Huston; Matt A Bernstein
Journal:  Phys Med Biol       Date:  2019-02-06       Impact factor: 3.609

4.  Lipid suppression in CSI with spatial priors and highly undersampled peripheral k-space.

Authors:  Berkin Bilgic; Borjan Gagoski; Trina Kok; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2012-07-17       Impact factor: 4.668

5.  Sparse parallel transmission on randomly perturbed spiral k-space trajectory.

Authors:  Yong Pang; Xiaohua Jiang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-04

6.  Application of the limited-memory quasi-Newton algorithm for multi-dimensional, large flip-angle RF pulses at 7T.

Authors:  Mads S Vinding; Daniel Brenner; Desmond H Y Tse; Sebastian Vellmer; Thomas Vosegaard; Dieter Suter; Tony Stöcker; Ivan I Maximov
Journal:  MAGMA       Date:  2016-08-02       Impact factor: 2.310

7.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

Authors:  Sun Hao; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  IEEE Trans Med Imaging       Date:  2015-09-15       Impact factor: 10.048

Review 8.  Parallel Transmission for Ultrahigh Field MRI.

Authors:  Cem M Deniz
Journal:  Top Magn Reson Imaging       Date:  2019-06

9.  Joint spatial-spectral reconstruction and k-t spirals for accelerated 2D spatial/1D spectral imaging of 13C dynamics.

Authors:  Jeremy W Gordon; David J Niles; Sean B Fain; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2013-05-28       Impact factor: 4.668

10.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.