Analysis of polyethylene component wear and implant loosening in total knee arthroplasty (TKA) requires precise knowledge of in vivo articular motion and loading conditions. This study presents a simultaneous in vivo measurement of tibiofemoral articular contact forces and contact kinematics in three TKA patients. These measurements were accomplished via a dual fluoroscopic imaging system and instrumented tibial implants, during dynamic single leg lunge and chair rising-sitting. The measured forces and contact locations were also used to determine mediolateral distribution of axial contact forces. Contact kinematics data showed a medial pivot during flexion of the knee, for all patients in the study. Average axial forces were higher for lunge compared to chair rising-sitting (224% vs. 187% body weight). In this study, we measured peak anteroposterior and mediolateral forces averaging 13.3% BW during lunge and 18.5% BW during chair rising-sitting. Mediolateral distributions of axial contact force were both patient and activity specific. All patients showed equitable medial-lateral loading during lunge but greater loads at the lateral compartment during chair rising-sitting. The results of this study may enable more accurate reproduction of in vivo loads and articular motion patterns in wear simulators and finite element models. This in turn may help advance our understanding of factors limiting longevity of TKA implants, such as aseptic loosening and polyethylene component wear, and enable improved TKA designs.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18538328      PMCID: PMC3177238          DOI: 10.1016/j.jbiomech.2008.04.021

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  31 in total

1.  In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty.

Authors:  J B Stiehl; D A Dennis; R D Komistek; H S Crane
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

2.  Femoral rollback after cruciate-retaining and stabilizing total knee arthroplasty.

Authors:  Ephrat Most; Shay Zayontz; Guoan Li; Erik Otterberg; Kenneth Sabbag; Harry E Rubash
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

3.  Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants.

Authors:  T M Wright; C M Rimnac; S D Stulberg; L Mintz; A K Tsao; R W Klein; C McCrae
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

Review 4.  The dominance of cyclic sliding in producing wear in total knee replacements.

Authors:  G W Blunn; P S Walker; A Joshi; K Hardinge
Journal:  Clin Orthop Relat Res       Date:  1991-12       Impact factor: 4.176

5.  The forces in the distal femur and the knee during walking and other activities measured by telemetry.

Authors:  S J Taylor; P S Walker; J S Perry; S R Cannon; R Woledge
Journal:  J Arthroplasty       Date:  1998-06       Impact factor: 4.757

6.  Instrumented implant for measuring tibiofemoral forces.

Authors:  K R Kaufman; N Kovacevic; S E Irby; C W Colwell
Journal:  J Biomech       Date:  1996-05       Impact factor: 2.712

7.  Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses.

Authors:  G W Blunn; A B Joshi; R J Minns; L Lidgren; P Lilley; L Ryd; E Engelbrecht; P S Walker
Journal:  J Arthroplasty       Date:  1997-04       Impact factor: 4.757

8.  A physiologically based criterion of muscle force prediction in locomotion.

Authors:  R D Crowninshield; R A Brand
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

9.  Implant design affects knee arthroplasty kinematics during stair-stepping.

Authors:  Scott A Banks; W Andrew Hodge
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

10.  Tibio-femoral loading during human gait and stair climbing.

Authors:  William R Taylor; Markus O Heller; Georg Bergmann; Georg N Duda
Journal:  J Orthop Res       Date:  2004-05       Impact factor: 3.494

View more
  16 in total

1.  Patient-specific computer model of dynamic squatting after total knee arthroplasty.

Authors:  Hideki Mizu-Uchi; Clifford W Colwell; Cesar Flores-Hernandez; Benjamin J Fregly; Shuichi Matsuda; Darryl D D'Lima
Journal:  J Arthroplasty       Date:  2015-01-10       Impact factor: 4.757

2.  Are Instrumented Knee Forces Representative of a Larger Population of Cruciate-Retaining Total Knee Arthroplasties?

Authors:  Ryan D Freed; Jacqueline C Simon; Christopher B Knowlton; Diego A Orozco Villaseñor; Markus A Wimmer; Hannah J Lundberg
Journal:  J Arthroplasty       Date:  2017-02-07       Impact factor: 4.757

3.  The 2011 ABJS Nicolas Andry Award: 'Lab'-in-a-knee: in vivo knee forces, kinematics, and contact analysis.

Authors:  Darryl D D'Lima; Shantanu Patil; Nicolai Steklov; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2011-05-20       Impact factor: 4.176

4.  Knee contact force in subjects with symmetrical OA grades: differences between OA severities.

Authors:  C Richards; J S Higginson
Journal:  J Biomech       Date:  2010-06-02       Impact factor: 2.712

Review 5.  Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.

Authors:  Corinne R Henak; Andrew E Anderson; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

6.  Evaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis.

Authors:  Tommaso Bonanzinga; Cecilia Signorelli; Marco Bontempi; Alessandro Russo; Stefano Zaffagnini; Maurilio Marcacci; Laura Bragonzoni
Journal:  Joints       Date:  2016-08-18

7.  Tibiofemoral kinematics and condylar motion during the stance phase of gait.

Authors:  Michal Kozanek; Ali Hosseini; Fang Liu; Samuel K Van de Velde; Thomas J Gill; Harry E Rubash; Guoan Li
Journal:  J Biomech       Date:  2009-06-03       Impact factor: 2.712

8.  An in vivo subject-specific 3D functional knee joint model using combined MR imaging.

Authors:  Bailiang Chen; Tryphon Lambrou; Amaka C Offiah; Pedro A Gondim Teixeira; Martin Fry; Andrew Todd-Pokropek
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-12-02       Impact factor: 2.924

9.  Subject-specific modeling of muscle force and knee contact in total knee arthroplasty.

Authors:  Alessandro Navacchia; Paul J Rullkoetter; Pascal Schütz; Renate B List; Clare K Fitzpatrick; Kevin B Shelburne
Journal:  J Orthop Res       Date:  2016-02-04       Impact factor: 3.494

10.  New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait.

Authors:  Guoan Li; Michal Kozanek; Ali Hosseini; Fang Liu; Samuel K Van de Velde; Harry E Rubash
Journal:  J Orthop Surg Res       Date:  2009-03-13       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.