Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants.

T M Wright1, C M Rimnac, S D Stulberg, L Mintz, A K Tsao, R W Klein, C McCrae.   

Abstract

Observations of wear damage were performed on 12 retrieved porous coated anatomic (PCA) tibial components, all of which were removed because of excessive polyethylene wear. Density measurements of the remaining polyethylene were obtained as a function of depth from the surface of the components. Comparison to previous results from similar studies of total condylar type knee components and total hip acetabular components revealed distinct differences between the types and severity of damage, emphasizing the influence of design factors on the corresponding wear damage. These results confirm previous conclusions that nonconforming articulating surfaces on thin polyethylene components will be at higher risk of damage than more conforming surfaces on thicker components. It also appears that the high cyclic loads to which polyethylene implants are subjected in vivo are most responsible for the degradation in properties of the material near the articulating surface, although the heat pressing of the articulating surface of the PCA components may contribute to the problem.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1537143

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  Does using autograft bone chips achieve consistent bone ingrowth in primary TKA?

Authors:  Roy D Bloebaum; Karyn E Koller; Bettina M Willie; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

3.  Wear damage in mobile-bearing TKA is as severe as that in fixed-bearing TKA.

Authors:  Natalie H Kelly; Rose H Fu; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  Tibiofemoral contact areas and pressures in six high flexion knees.

Authors:  Kei Shiramizu; Frank Vizesi; Warwick Bruce; Sebastian Herrmann; William R Walsh
Journal:  Int Orthop       Date:  2007-11-22       Impact factor: 3.075

5.  Rotating-platform has no surface damage advantage over fixed-bearing TKA.

Authors:  Kirsten Stoner; Seth A Jerabek; Stephanie Tow; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

6.  Assessment of posterior stability in total knee replacement by stress radiographs: prospective comparison of two different types of mobile bearing implants.

Authors:  S Louisia; R Siebold; J Canty; R J Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-04-02       Impact factor: 4.342

Review 7.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

8.  Radiostereometric measurement of polyethylene deformation pattern in meniscal bearing TKR at 5 years follow-up.

Authors:  Alessandro Russo; Laura Bragonzoni; Claudia Trozzi; Francesco Iacono; Andrea Visani; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-16       Impact factor: 4.342

9.  Survivorship comparison of all-polyethylene and metal-backed tibial components in cruciate-substituting total knee arthroplasty--Chinese experience.

Authors:  Bin Shen; Jing Yang; Zongke Zhou; Pengde Kang; Liao Wang; Fuxing Pei
Journal:  Int Orthop       Date:  2008-08-08       Impact factor: 3.075

10.  In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities.

Authors:  Kartik M Varadarajan; Angela L Moynihan; Darryl D'Lima; Clifford W Colwell; Guoan Li
Journal:  J Biomech       Date:  2008-06-05       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.