Literature DB >> 18537779

Limb-length measurement in total hip arthroplasty using a calipers dual pin retractor.

Iori Takigami1, Mansho Itokazu, Yoshiki Itoh, Kazu Matsumoto, Takatoshi Yamamoto, Katsuji Shimizu.   

Abstract

BACKGROUND: Limb-length inequality is not uncommon after total hip arthroplasty (THA) and may cause subjective problems for patients. During THA a stable reference point must be established to determine changes in leg length. Several methods have been useful in minimizing the incidence and magnitude of this problem. The equalization of leg-length discrepancy during THA can be achieved through the use of a simple measuring device, the calipers dual pin retractor (CDPR).
MATERIALS AND METHODS: The CDPR was developed to establish a fixed point on the pelvis that would remain constant throughout the procedure and from which the distance to the greater trochanter could be measured prior to dislocation of the hip. Limb lengths were measured in 56 patients undergoing primary THA, between 2004 and 2006. The CDPR was used in all cases.
RESULTS: The preoperative diagnoses were osteoarthritis in 44 patients, osteonecrosis in five, and rheumatoid arthritis in seven. Average postoperative limb-length inequality was 4.2 mm. None of the patients had to use shoe lifts for equalization of limb lengths or complained of limb-length inequality.
CONCLUSION: This method of measurement is beneficial with most THA approaches, and the technique is helpful for minimizing limb-length inequality during THA.

Entities:  

Mesh:

Year:  2008        PMID: 18537779

Source DB:  PubMed          Journal:  Bull NYU Hosp Jt Dis        ISSN: 1936-9719


  6 in total

1.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

3.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

4.  Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty.

Authors:  Wayne G Paprosky; Jeffrey M Muir
Journal:  Med Devices (Auckl)       Date:  2016-11-18

5.  Intraoperative measurement of limb lengthening during total hip arthroplasty.

Authors:  Dimitrios Vasileiou Papadopoulos; Panagiotis Koulouvaris; Georgios Charalambos Aggelidakis; Andreas Georgios Tsantes; Marios Georgios Lykissas; Alexandros Mavrodontidis
Journal:  Indian J Orthop       Date:  2017 Mar-Apr       Impact factor: 1.251

6.  An intraoperative device to restore femoral offset in total hip arthroplasty.

Authors:  Enxing Xue; Zhen Su; Chengwang Chen; Paul Kim Chiu Wong; Hong Wen; Yu Zhang
Journal:  J Orthop Surg Res       Date:  2014-07-19       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.