PURPOSE: To evaluate the liver-to-muscle signal intensity and R2* methods to gain a transferable, clinical application for liver iron measurement.
MATERIALS AND METHODS: Sixteen liver phantoms and 33 human subjects were examined using three 1.5-T MRI scanners from two different vendors. Phantom-to-muscle and liver-to-muscle signal intensity ratios were analyzed to determine MRI estimated phantom and hepatic iron concentration (M-PIC and M-HIC, respectively). R2* was calculated for the phantoms and the liver of human subjects. Seven patients' biochemical hepatic iron concentration was obtained.
RESULTS: M-PIC and R2* results of three scanners correlated linearly to phantom iron concentrations (r=0.984 to 0.989 and r=0.972 to 0.981, respectively), and no significant difference between the scanners was found (P=.482 and P=.846, respectively) in vitro. The patients' R2* correlated linearly to M-HIC of the standard scanner (r=0.981). M-HIC values did not differ from those obtained from the biopsy specimens (P=.230). The difference in M-HIC was significant, but the difference in R2* was not significant between the scanners (P<.0001 and P=.505, respectively) in vivo.
CONCLUSION: Both methods, M-HIC and R2*, are reliable iron concentration indicators with linear dependence on iron concentration in vivo and in vitro. The R2* method was found to be comparable among different scanners. Transferability testing is needed for the use of the methods at various scanners.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18524528     DOI: 10.1016/j.mri.2008.01.028

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  20 in total

Review 1.  Magnetic resonance imaging quantification of liver iron.

Authors:  Claude B Sirlin; Scott B Reeder
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

2.  Comparison of whole liver and small region-of-interest measurements of MRI liver R2* in children with iron overload.

Authors:  M Beth McCarville; Claudia M Hillenbrand; Ralf B Loeffler; Matthew P Smeltzer; Ruitan Song; Chin-Shang Li; Jane S Hankins
Journal:  Pediatr Radiol       Date:  2010-03-24

3.  Automated vessel exclusion technique for quantitative assessment of hepatic iron overload by R2*-MRI.

Authors:  Aaryani Tipirneni-Sajja; Ruitian Song; M Beth McCarville; Ralf B Loeffler; Jane S Hankins; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2017-10-30       Impact factor: 4.813

Review 4.  Liver iron content determination by magnetic resonance imaging.

Authors:  Konstantinos Tziomalos; Vassilios Perifanis
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

5.  Serial quantitative neuroimaging of iron in the intracerebral hemorrhage pig model.

Authors:  Muhammad E Haque; Refaat E Gabr; Xiurong Zhao; Khader M Hasan; Andrew Valenzuela; Ponnada A Narayana; Shun-Ming Ting; Guanghua Sun; Sean I Savitz; Jaroslaw Aronowski
Journal:  J Cereb Blood Flow Metab       Date:  2018-01-02       Impact factor: 6.200

6.  Polystyrene microsphere-ferritin conjugates: a robust phantom for correlation of relaxivity and size distribution.

Authors:  Preeti A Sukerkar; Uzma G Rezvi; Keith W Macrenaris; Pinal C Patel; John C Wood; Thomas J Meade
Journal:  Magn Reson Med       Date:  2010-10-28       Impact factor: 4.668

Review 7.  Assessing the Non-tumorous Liver: Implications for Patient Management and Surgical Therapy.

Authors:  Pallavi Pandey; Ankur Pandey; Mary Dillhoff; Carl Schmidt; Ihab R Kamel; Timothy M Pawlik
Journal:  J Gastrointest Surg       Date:  2017-09-18       Impact factor: 3.452

8.  Improved R2* measurement accuracy with absolute SNR truncation and optimal coil combination.

Authors:  Xiaoming Yin; Saurabh Shah; Aggelos K Katsaggelos; Andrew C Larson
Journal:  NMR Biomed       Date:  2010-12       Impact factor: 4.044

Review 9.  Quantification of liver iron with MRI: state of the art and remaining challenges.

Authors:  Diego Hernando; Yakir S Levin; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2014-03-03       Impact factor: 4.813

10.  Effect of multipeak spectral modeling of fat for liver iron and fat quantification: correlation of biopsy with MR imaging results.

Authors:  Jens-Peter Kühn; Diego Hernando; Alejandro Muñoz del Rio; Matthias Evert; Stephan Kannengiesser; Henry Völzke; Birger Mensel; Ralf Puls; Norbert Hosten; Scott B Reeder
Journal:  Radiology       Date:  2012-08-24       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.