Literature DB >> 18519323

Total hip arthroplasty with an uncemented tapered femoral component.

Jeffrey R McLaughlin1, Kyla R Lee.   

Abstract

BACKGROUND: Excellent intermediate-term results with use of tapered femoral components in primary total hip arthroplasty have been reported. The purpose of this study was to update our previous report and to evaluate the outcome of total hip arthroplasty with use of the porous Taperloc femoral component in patients who had been followed for a minimum of eighteen years postoperatively.
METHODS: One hundred and forty-five consecutive uncemented total hip arthroplasties in 138 patients were performed between 1983 and 1985, by a single surgeon, with use of the Taperloc femoral component. The outcome of every femoral component with regard to stem fixation, retention, or revision was determined for all 145 total hip replacements. At a mean of twenty years (range, eighteen to 22.6 years) postoperatively, fifty-eight patients (sixty-five hips) were living. In fifty living patients (fifty-seven hips), the femoral component had not undergone revision surgery. Evaluation of the living patients included clinical and radiographic analysis and recording of complications.
RESULTS: Of the eighty patients (eighty hips) who had died, five hips had undergone revision of the femoral component. Only one stem had been revised for aseptic loosening, and no femoral component had been definitely loose by radiographic criteria. In the remaining sixty-five hips in the fifty-eight living patients, eight femoral components were revised. No femoral component underwent revision for aseptic loosening. Definite radiographic evidence of femoral component loosening occurred in one hip. In the fifty living patients (fifty-seven hips) who had not undergone femoral component revision, there was a significant improvement in the mean Harris hip score from 49.3 points preoperatively to 85.4 points at the time of latest follow-up (p = 0.001). Survivorship analysis of all 145 hips, with revision for any reason as the end point, estimated that the survival rate for the femoral component was 87% (95% confidence interval, 79% to 93%) at twenty-two years.
CONCLUSIONS: Primary total hip arthroplasty with the Taperloc femoral component is associated with a low rate of aseptic loosening at a mean follow-up of twenty years.

Entities:  

Mesh:

Year:  2008        PMID: 18519323     DOI: 10.2106/JBJS.G.00771

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  34 in total

1.  Survival of the cementless Spotorno stem in the second decade.

Authors:  Peter R Aldinger; Alexander W Jung; Steffen J Breusch; Volker Ewerbeck; Dominik Parsch
Journal:  Clin Orthop Relat Res       Date:  2009-06-06       Impact factor: 4.176

2.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

3.  Total hip arthroplasty at the rothman institute.

Authors:  Matthew S Austin; Carlos A Higuera; Richard H Rothman
Journal:  HSS J       Date:  2012-04-17

4.  Cementless femoral prostheses cost more to implant than cemented femoral prostheses.

Authors:  Aasis Unnanuntana; Apostolos Dimitroulias; Michael P Bolognesi; Katherine L Hwang; Stuart B Goodman; Randall E Marcus
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

5.  What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial.

Authors:  Kristoff Corten; Robert B Bourne; Kory D Charron; Keegan Au; Cecil H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

6.  Twenty-year followup of an uncemented stem in primary THA.

Authors:  John B Meding; Merrill A Ritter; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

7.  The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-06-22

8.  Blood loss and transfusion rate in short stem hip arthroplasty. A comparative study.

Authors:  Josef Hochreiter; Wilfried Hejkrlik; Katja Emmanuel; Wolfgang Hitzl; Reinhold Ortmaier
Journal:  Int Orthop       Date:  2016-12-10       Impact factor: 3.075

9.  Presence of interleukin-17C in the tissue around aseptic loosened implants.

Authors:  Changhe Hou; Yangchun Zhang; Shiming Yu; Ziqing Li; Qiyi Zhai; Zhanchun Li; Xibao Zhang; Jianhong Xiao; Puyi Sheng
Journal:  Int Orthop       Date:  2013-03-10       Impact factor: 3.075

10.  Long-term (20- to 25-year) results of an uncemented tapered titanium femoral component and factors affecting survivorship.

Authors:  Marcus R Streit; Moritz M Innmann; Christian Merle; Thomas Bruckner; Peter R Aldinger; Tobias Gotterbarm
Journal:  Clin Orthop Relat Res       Date:  2013-05-14       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.