Literature DB >> 18518091

Stability of the proton-to-electron mass ratio.

A Shelkovnikov1, R J Butcher, C Chardonnet, A Amy-Klein.   

Abstract

We report a limit on the fractional temporal variation of the proton-to-electron mass ratio as 1/(m(P)/m(e)) partial differential/partial differential(t)(m(P)/m(e))=(-3.8+/-5.6) x 10(-14) yr(-1), obtained by comparing the frequency of a rovibrational transition in SF6 with the fundamental hyperfine transition in Cs. The SF6 transition was accessed using a CO2 laser to interrogate spatial 2-photon Ramsey fringes. The atomic transition was accessed using a primary standard controlled with a Cs fountain. This result is direct and model-free.

Entities:  

Year:  2008        PMID: 18518091     DOI: 10.1103/PhysRevLett.100.150801

Source DB:  PubMed          Journal:  Phys Rev Lett        ISSN: 0031-9007            Impact factor:   9.161


  6 in total

Review 1.  Varying Constants, Gravitation and Cosmology.

Authors:  Jean-Philippe Uzan
Journal:  Living Rev Relativ       Date:  2011-03-29       Impact factor: 40.429

2.  Laser Cooling with an Intermediate State and Electronic Structure Studies of the Molecules CaCs and CaNa.

Authors:  Amal Moussa; Nayla El-Kork; Israa Zeid; Ehab Salem; Mahmoud Korek
Journal:  ACS Omega       Date:  2022-05-24

3.  A search for varying fundamental constants using hertz-level frequency measurements of cold CH molecules.

Authors:  S Truppe; R J Hendricks; S K Tokunaga; H J Lewandowski; M G Kozlov; Christian Henkel; E A Hinds; M R Tarbutt
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

4.  Tunable Microcavity-Stabilized Quantum Cascade Laser for Mid-IR High-Resolution Spectroscopy and Sensing.

Authors:  Simone Borri; Mario Siciliani de Cumis; Giacomo Insero; Saverio Bartalini; Pablo Cancio Pastor; Davide Mazzotti; Iacopo Galli; Giovanni Giusfredi; Gabriele Santambrogio; Anatoliy Savchenkov; Danny Eliyahu; Vladimir Ilchenko; Naota Akikusa; Andrey Matsko; Lute Maleki; Paolo De Natale
Journal:  Sensors (Basel)       Date:  2016-02-17       Impact factor: 3.576

5.  Ultra-low noise optical injection locking amplifier with AOM-based coherent detection scheme.

Authors:  Zitong Feng; Fei Yang; Xi Zhang; Dijun Chen; Fang Wei; Nan Cheng; Yanguang Sun; Youzhen Gui; Haiwen Cai
Journal:  Sci Rep       Date:  2018-09-03       Impact factor: 4.379

6.  Measuring molecular frequencies in the 1-10 μm range at 11-digits accuracy.

Authors:  G Insero; S Borri; D Calonico; P Cancio Pastor; C Clivati; D D'Ambrosio; P De Natale; M Inguscio; F Levi; G Santambrogio
Journal:  Sci Rep       Date:  2017-10-06       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.