Abstract

A total of 50 total knee arthroplasty (TKA) patients, 25 traditional and 25 minimally invasive surgical (MIS), underwent computed tomography scans to determine if a loss of accuracy in implant alignment occurred when a surgeon switched from a traditional medial parapatellar arthrotomy to a mini-subvastus surgical technique. Surgical accuracy was determined by comparing the computed tomography measured implant alignment with the surgical alignment goals. There was no loss in accuracy in the implantation of the tibial component with the mini-subvastus technique. The mean variance for the tibial coronal alignment was 1.03 degrees for the traditional TKA and 1.00 degrees for the MIS TKA (P = .183). Similarly, there was no difference in the mean variance for the posterior tibial slope (P = .054). Femoral coronal alignment was less accurate with the MIS procedure, mean variance of 1.04 degrees and 1.71 degrees for the traditional and MIS TKA, respectively (P = .045). Instrumentation and surgical technique concerns that led to this loss in accuracy were determined.

Entities:  

Mesh:

Year:  2007        PMID: 18514872     DOI: 10.1016/j.arth.2007.05.034

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Faster recovery after minimally invasive surgery in total knee arthroplasty.

Authors:  Emmanuel Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-31       Impact factor: 4.342

2.  Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty.

Authors:  Yasuo Niki
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-30       Impact factor: 4.342

3.  [Current role of minimally invasive total knee arthroplasty. A meta-analysis].

Authors:  T Kappe; M Flören; R Bieger; H Reichel
Journal:  Orthopade       Date:  2011-08       Impact factor: 1.087

4.  Faster quadriceps recovery with the far medial subvastus approach in minimally invasive total knee arthroplasty.

Authors:  Emmanuel Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-09-25       Impact factor: 4.342

5.  [Mini-subvastus approach for total knee replacement].

Authors:  Andreas Halder; Alexander Beier; Wolfram Neumann
Journal:  Oper Orthop Traumatol       Date:  2009-03       Impact factor: 1.154

6.  Computer-assisted total knee arthroplasty using mini midvastus or medial parapatellar approach technique: A prospective, randomized, international multicentre trial.

Authors:  Peter Feczko; Lutz Engelmann; Jacobus J Arts; David Campbell
Journal:  BMC Musculoskelet Disord       Date:  2016-01-13       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.