Literature DB >> 18514868

Analysis and results of dissociation of the polyethylene liner in the Harris-Galante I acetabular component.

Shu Saito1, Junnosuke Ryu, Masayuki Seki, Takao Ishii, Kaichiro Saigo, Sei Mori.   

Abstract

The Harris-Galante I modular acetabular components (Zimmer, Warsaw, Ind) were most widely used in the 1980s in primary and revision total hip arthroplasty. We assessed 76 primary total hip arthroplasties performed using Harris-Galante I modular acetabular components. Dissociation of the polyethylene liner occurred in 5 patients and required revision surgery. None of the 76 hips had fractures of the metal locking tines on the metal shell. Liner dissociation was attributed to fatigue fracture of the polyethylene, a result of a gap between the liner and the metal shell. The thin polyethylene liner rim aggravated failure. The revision technique was to cement the polyethylene liner into the well-fixed Harris-Galante metal shell. The average follow-up observation period after revision surgery was 6.4 years; and there was no recurrence of dissociation, which supports the use of our revision technique.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18514868     DOI: 10.1016/j.arth.2007.06.004

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Case report: Painless chronic liner dissociation of a total hip arthroplasty.

Authors:  Jorm M Nellensteijn; David R Nellensteijn; Tjitte De Jong
Journal:  Clin Orthop Relat Res       Date:  2013-02-21       Impact factor: 4.176

2.  Distinctive damage patterns on THA metal bearing surfaces: case studies.

Authors:  Anneliese D Heiner; Nishant M Tikekar; Karen M Kruger; John J Lannutti; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2014

3.  Polyethylene Liner Dissociation Is a Complication of the DePuy Pinnacle Cup: A Report of 23 Cases.

Authors:  Andrew Yun; Emmanuel N Koli; John Moreland; Richard Iorio; John F Tilzey; J Wesley Mesko; Gwo-Chin Lee; Mark Froimson
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

4.  Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review.

Authors:  Naga Cheppalli; Akshay Goel; Audry Wassef; Amit W Bhandarkar; Samer Kakish
Journal:  Cureus       Date:  2022-05-18

5.  Highly Cross-linked Polyethylene Liner Dissociation from a Cement-less Modular Acetabular Shell: Two Case Reports.

Authors:  Shunsuke Kawano; Motoki Sonohata; Masaru Kitajima; Masaaki Mawatari
Journal:  Open Orthop J       Date:  2016-12-26

6.  Average 22-Year Results of Total Hip Arthroplasty Using Harris-Galante Prosthesis in Patients under 50 Years.

Authors:  Heejae Won; Seung-Hoon Baek; Junekyu Kim; Won Kee Lee; Yeon Soo Lee; Shin-Yoon Kim
Journal:  Clin Orthop Surg       Date:  2022-03-03

7.  Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years.

Authors:  Keisha French; Rebecca Moore; Heather Gawel; Steven M Kurtz; Matthew J Kraay; Ke Xie; Victor M Goldberg; Clare M Rimnac
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

8.  Prosthetic femoral head erosion through an acetabular component treated with revision and implant preservation.

Authors:  Mark Daniel Kohn; Navin Fernando
Journal:  Arthroplast Today       Date:  2020-01-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.