| Literature DB >> 23430718 |
Jorm M Nellensteijn1, David R Nellensteijn, Tjitte De Jong.
Abstract
BACKGROUND: Dislocation or liner dissociation of a total hip prosthesis usually results in pain and discomfort. Although several reports describe chronic dislocation and its treatment, chronic liner dissociation is an unreported complication. CASE DESCRIPTION: We report an unrecognized dissociation and displacement of the liner of a total hip prosthesis after revision THA. The patient had virtually no pain or functional restrictions. The patient's only complaint was pain on the contralateral side, associated with a leg-length discrepancy. Since the patient had no complaints relative to the liner dissociation we elected not to pursue further treatment. The contralateral pain was treated successfully with a shoe lift. LITERATURE REVIEW: Chronic dislocation of a THA is a rare complication and we found reports of only seven cases in the literature. We found no reports of chronic liner dissociation. CLINICAL RELEVANCE: Orthopaedic surgeons should be aware of the possibility of this rare complication. Our case and the literature suggest treatment can be nonsurgical or surgical.Entities:
Mesh:
Year: 2013 PMID: 23430718 PMCID: PMC3706646 DOI: 10.1007/s11999-012-2759-8
Source DB: PubMed Journal: Clin Orthop Relat Res ISSN: 0009-921X Impact factor: 4.176