Literature DB >> 19037641

Measurement of knee joint motion using digital imaging.

Damien Bennett1, Brian Hanratty, Neville Thompson, David Beverland.   

Abstract

The measurement of joint motion is common practice in many aspects of orthopaedic surgery. A number of techniques and instruments have been developed for this purpose. We describe a method of recording and measuring knee joint motion using digital imaging which demonstrated high inter-observer reliability (r > 0.948) and intra-observer repeatability (r > 0.906). This technique may offer some practical advantages over other methods of measuring joint motion.

Mesh:

Year:  2008        PMID: 19037641      PMCID: PMC2899156          DOI: 10.1007/s00264-008-0694-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Digital cameras.

Authors:  I Hutchinson; P Williams
Journal:  Br J Orthod       Date:  1999-12

Review 2.  Digital imaging in trauma and orthopaedic surgery: is it worth it?

Authors:  F A Wade; C W Oliver; K McBride
Journal:  J Bone Joint Surg Br       Date:  2000-08

3.  Digital photography and computerisation in orthopaedics.

Authors:  E T Mah; N O B Thomsen
Journal:  J Bone Joint Surg Br       Date:  2004-01

Review 4.  Living with digital imaging.

Authors:  Frazer A Wade; Christopher W Oliver
Journal:  Clin Orthop Relat Res       Date:  2004-04       Impact factor: 4.176

5.  Reliability and validity of goniometric measurements at the knee.

Authors:  P P Gogia; J H Braatz; S J Rose; B J Norton
Journal:  Phys Ther       Date:  1987-02

6.  Goniometric reliability in a clinical setting. Elbow and knee measurements.

Authors:  J M Rothstein; P J Miller; R F Roettger
Journal:  Phys Ther       Date:  1983-10

7.  Digital imaging in clinical photography, Part 1.

Authors:  S Brown
Journal:  J Audiov Media Med       Date:  1994-04

8.  Sources of goniometric error at the elbow.

Authors:  D R Fish; L Wingate
Journal:  Phys Ther       Date:  1985-11

9.  Measuring flexion in knee arthroplasty patients.

Authors:  John Z Edwards; Kenneth A Greene; Robert S Davis; Mark W Kovacik; Donald A Noe; Michael J Askew
Journal:  J Arthroplasty       Date:  2004-04       Impact factor: 4.757

10.  Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting.

Authors:  M A Watkins; D L Riddle; R L Lamb; W J Personius
Journal:  Phys Ther       Date:  1991-02
View more
  9 in total

1.  Is there a difference in sagittal alignment of Blount's disease between radiographic and clinical evaluation?

Authors:  Seung-Ju Kim; Sanjeev Sabharwal
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

2.  Comparative analysis of photograph-based clinical goniometry to standard techniques.

Authors:  Jared A Crasto; Arash J Sayari; Robert R-L Gray; Morad Askari
Journal:  Hand (N Y)       Date:  2015-06

3.  Measurement of the knee flexion angle with smartphone applications: Which technology is better?

Authors:  Jean-Yves Jenny; Abdullah Bureggah; Yann Diesinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-02-15       Impact factor: 4.342

4.  Effects of moving cupping therapy on hip and knee range of movement and knee flexion power: a preliminary investigation.

Authors:  Dana Murray; Carl Clarkson
Journal:  J Man Manip Ther       Date:  2019-04-19

5.  Application of a vibrating device for the prevention of flexion contracture after total knee arthroplasty.

Authors:  Sándor Manó; Judit Pálinkás; János Szabó; Judit T Nagy; Katalin Bakó; Zoltán Csernátony
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-04-29

6.  Reliability and validity of angle measurements using radiograph and smartphone applications: experimental research on protractor.

Authors:  Takenori Awatani; Taisuke Enoki; Ikuhiro Morikita
Journal:  J Phys Ther Sci       Date:  2017-10-21

7.  Development of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgus.

Authors:  Guoli Li; Jinsong Shen; Edward Smith; Chetna Patel
Journal:  Int J Environ Res Public Health       Date:  2022-07-26       Impact factor: 4.614

8.  Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F.

Authors:  Jun-Young Kim; Sang-Ho Cheon; Hee-Soo Kyung
Journal:  Knee Surg Relat Res       Date:  2012-11-29

9.  Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

Authors:  Russell R Russo; Matthew B Burn; Sabir K Ismaily; Brayden J Gerrie; Shuyang Han; Jerry Alexander; Christopher Lenherr; Philip C Noble; Joshua D Harris; Patrick C McCulloch
Journal:  J Exp Orthop       Date:  2017-09-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.