Literature DB >> 18512848

Isobaric metabolite interferences and the requirement for close examination of raw data in addition to stringent chromatographic separations in liquid chromatography/tandem mass spectrometric analysis of drugs in biological matrix.

Zhengyin Yan1, Noureddine Maher, Rhoda Torres, Carlos Cotto, Becki Hastings, Malini Dasgupta, Rolanda Hyman, Norman Huebert, Gary W Caldwell.   

Abstract

In addition to matrix effects, common interferences observed in liquid chromatography/tandem mass spectrometry (LC/MS/MS) analyses can be caused by the response of drug-related metabolites to the multiple reaction monitoring (MRM) channel of a given drug, as a result of in-source reactions or decomposition of either phase I or II metabolites. However, it has been largely ignored that, for some drugs, metabolism can lead to the formation of isobaric or isomeric metabolites that exhibit the same MRM transitions as parent drugs. The present study describes two examples demonstrating that interference caused by isobaric or isomeric metabolites is a practical issue in analyzing biological samples by LC/MS/MS. In the first case, two sequential metabolic reactions, demethylation followed by oxidation of a primary alcohol moiety to a carboxylic acid, produced an isobaric metabolite that exhibits a MRM transition identical to the parent drug. Because the drug compound was rapidly metabolized in rats and completely disappeared in plasma samples, the isobaric metabolite appeared as a single peak in the total ion current (TIC) trace and could easily be quantified as the drug since it was eluted at a retention time very close to that of the drug in a 12-min LC run. In the second example, metabolism via the ring-opening of a substituted isoxazole moiety led to the formation of an isomeric product that showed an almost identical collision-induced dissociation (CID) MS spectrum as the original drug. Because two components were co-eluted, the isomeric product could be mistakenly quantified and reported by data processing software as the parent drug if the TIC trace was not carefully inspected. Nowadays, all LC/MS data are processed by computer software in a highly automated fashion, and some analysts may spend much less time to visually examine raw TIC traces than they used to do. Two examples described in this article remind us that quality data require both adequate chromatographic separations and close examination of raw data in LC/MS/MS analyses of drugs in biological matrix.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18512848     DOI: 10.1002/rcm.3577

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  7 in total

1.  Development and validation of an LC-MS/MS method for determination of the L-type voltage-gated calcium channel/NMDA receptor antagonist NGP1-01 in mouse serum.

Authors:  Harini Jogiraju; Xiang Zhou; Ashta Lakshmi Prasad Gobburi; Kiran K Pedada; Werner J Geldenhuys; Cornelis J Van der Schyf; Samuel D Crish; David J Anderson
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-06-02       Impact factor: 3.205

2.  Automated detection of inaccurate and imprecise transitions in peptide quantification by multiple reaction monitoring mass spectrometry.

Authors:  Susan E Abbatiello; D R Mani; Hasmik Keshishian; Steven A Carr
Journal:  Clin Chem       Date:  2009-12-18       Impact factor: 8.327

3.  Applications of selected reaction monitoring (SRM)-mass spectrometry (MS) for quantitative measurement of signaling pathways.

Authors:  Yingxin Zhao; Allan R Brasier
Journal:  Methods       Date:  2013-02-11       Impact factor: 3.608

4.  Deployment-Associated Exposure Surveillance With High-Resolution Metabolomics.

Authors:  Douglas I Walker; Col Timothy M Mallon; Philip K Hopke; Karan Uppal; Young-Mi Go; Patricia Rohrbeck; Kurt D Pennell; Dean P Jones
Journal:  J Occup Environ Med       Date:  2016-08       Impact factor: 2.162

5.  Study of Isobaric Interference in Quantification of Citrulline by Parallel Fragmentation Monitoring.

Authors:  Eddy Wing Yin Ng; Hugh Simon Lam; Pak Cheung Ng; Terence Chuen Wai Poon
Journal:  Mass Spectrom (Tokyo)       Date:  2014-05-01

Review 6.  Steroid assays in paediatric endocrinology.

Authors:  John W Honour
Journal:  J Clin Res Pediatr Endocrinol       Date:  2010-02-01

7.  Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomics.

Authors:  D R Mani; Susan E Abbatiello; Steven A Carr
Journal:  BMC Bioinformatics       Date:  2012-11-05       Impact factor: 3.169

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.