Literature DB >> 26819902

Study of Isobaric Interference in Quantification of Citrulline by Parallel Fragmentation Monitoring.

Eddy Wing Yin Ng1, Hugh Simon Lam2, Pak Cheung Ng2, Terence Chuen Wai Poon1.   

Abstract

Parallel Fragmentation Monitoring (PFM), which is an analogue of selected reaction monitoring (SRM), is a recently developed method for quantification of small molecules by MALDI-TOF/TOF mass spectrometry (MS). It is well known that isobaric interference substances can be occasionally present in complex biological samples, and affect the accuracy of measurement by SRM. Unfortunately, by design it is not possible to assess whether isobaric interference happens in a SRM analysis. In contrast, the unique design of PFM should allow quick inspection for isobaric interference and subsequent correction. In this study, using arginine as an example, interference effect of isobaric structural analogs on the quantification of citrulline by PFM was evaluated. Our results showed that the presence of arginine affected the measured concentrations of citrulline standard solutions in a concentration dependent manner. Such interference could be observed readily in the MS/MS spectra, and contributed by [arginine+H-NH3](+) fragment ion. Because of having highly similar mass, (13)C-isotope of [arginine+H-NH3](+) fragment ion overlapped with monoisotope of [citrulline+H-NH3](+) fragment ion, which was used as the report ion for quantification. However, such interference could be mathematically eliminated or minimized through estimation of the signal intensity of the (13)C-isotopic peak of [arginine+H-NH3](+) from the intensity of the corresponding monoisotopic peak according to isotope distribution of elements. Furthermore, the presence of interfering fragment ions could be avoided by optimizing MALDI ionization condition. In conclusion, isobaric interference can happen in PFM, but can be easily identified in the mass spectra and eliminated (minimized) with simple methods.

Entities:  

Keywords:  MALDI-TOF/TOF MS; amino acid; isobaric interference; parallel fragmentation monitoring; quantification

Year:  2014        PMID: 26819902      PMCID: PMC4541149          DOI: 10.5702/massspectrometry.S0030

Source DB:  PubMed          Journal:  Mass Spectrom (Tokyo)        ISSN: 2186-5116


  20 in total

1.  Application of liquid chromatography with electrospray tandem mass spectrometry to the determination of a new generation of pesticides in processed fruits and vegetables.

Authors:  Anna Sannino; Luciana Bolzoni; Mirella Bandini
Journal:  J Chromatogr A       Date:  2004-05-21       Impact factor: 4.759

2.  Amino acid analysis by means of MALDI TOF mass spectrometry or MALDI TOF/TOF tandem mass spectrometry.

Authors:  Natalia V Gogichaeva; Michail A Alterman
Journal:  Methods Mol Biol       Date:  2012

3.  Use of high-resolution mass spectrometry to investigate a metabolite interference during liquid chromatography/tandem mass spectrometric quantification of a small molecule in toxicokinetic study samples.

Authors:  Michael Furlong; Andrew Bessire; Wei Song; Christopher Huntington; Elizabeth Groeber
Journal:  Rapid Commun Mass Spectrom       Date:  2010-07-15       Impact factor: 2.419

4.  Ion-pairing reversed-phase liquid chromatography/electrospray ionization mass spectrometric analysis of 76 underivatized amino acids of biological interest: a new tool for the diagnosis of inherited disorders of amino acid metabolism.

Authors:  Monique Piraud; Christine Vianey-Saban; Konstantinos Petritis; Claire Elfakir; Jean-Paul Steghens; Denis Bouchu
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

5.  Simultaneously quantifying parent drugs and screening for metabolites in plasma pharmacokinetic samples using selected reaction monitoring information-dependent acquisition on a QTrap instrument.

Authors:  Austin C Li; Dennis Alton; Matthew S Bryant; Wilson Z Shou
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

6.  Assessing the properties of internal standards for quantitative matrix-assisted laser desorption/ionization mass spectrometry of small molecules.

Authors:  Lekha Sleno; Dietrich A Volmer
Journal:  Rapid Commun Mass Spectrom       Date:  2006       Impact factor: 2.419

7.  Automated detection of inaccurate and imprecise transitions in peptide quantification by multiple reaction monitoring mass spectrometry.

Authors:  Susan E Abbatiello; D R Mani; Hasmik Keshishian; Steven A Carr
Journal:  Clin Chem       Date:  2009-12-18       Impact factor: 8.327

8.  MALDI TOF/TOF tandem mass spectrometry as a new tool for amino acid analysis.

Authors:  Natalia V Gogichaeva; Todd Williams; Michail A Alterman
Journal:  J Am Soc Mass Spectrom       Date:  2006-10-30       Impact factor: 3.109

9.  Precolumn derivatization reagents for high-speed analysis of amines and amino acids in biological fluid using liquid chromatography/electrospray ionization tandem mass spectrometry.

Authors:  Kazutaka Shimbo; Takashi Oonuki; Akihisa Yahashi; Kazuo Hirayama; Hiroshi Miyano
Journal:  Rapid Commun Mass Spectrom       Date:  2009-05       Impact factor: 2.419

10.  Detection and correction of interference in SRM analysis.

Authors:  Y Bao; S Waldemarson; G Zhang; A Wahlander; B Ueberheide; S Myung; B Reed; K Molloy; J C Padovan; J Eriksson; T A Neubert; B T Chait; D Fenyö
Journal:  Methods       Date:  2013-05-23       Impact factor: 3.608

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.