Literature DB >> 18512094

Real-time transesophageal three-dimensional echocardiography for guidance of percutaneous cardiac interventions: first experience.

Jan Balzer1, Harald Kühl, Tienush Rassaf, Rainer Hoffmann, Patrick Schauerte, Malte Kelm, Andreas Franke.   

Abstract

Recently, a new generation of transesophageal echocardiography (TEE) probes with a novel matrix array technique was introduced, allowing three-dimensional (3D) presentation of cardiac structures in real-time. This article aims to describe our first experiences with this new technique in the guidance of percutaneous cardiac interventions in the catheter laboratory. We used a matrix array 3D TEE probe connected to a 3D-capable echocardiographic system. The 3D TEE system provides exact imaging of the pathomorphology of cardiac structures as well as intracardiac catheters and devices in real-time. We applied this innovative technique to monitor percutaneous cardiac interventions in the catheter laboratory, such as atrial septal defect (ASD) or patent foramen ovale (PFO) closures, revalving procedures such as percutaneous transvenous mitral valve annuloplasty (PTMA), aortic valve replacements, and electrophysiological procedures. Our findings demonstrate that real-time 3D TEE provides a novel imaging technique to guide interventions in the catheter laboratory, providing fast and complete information about the underlying pathomorphology, improving spatial orientation, and additionally monitoring online the procedure without loss of image quality. These benefits may accelerate the learning curve and improve confidence of the interventional cardiologist in order to increase safety, accuracy, and efficacy of interventional cardiac procedures.

Entities:  

Mesh:

Year:  2008        PMID: 18512094     DOI: 10.1007/s00392-008-0676-3

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  27 in total

Review 1.  Three-dimensional echocardiography of the atrial septum.

Authors:  G R Marx; M C Sherwood; C Fleishman; R Van Praagh
Journal:  Echocardiography       Date:  2001-07       Impact factor: 1.724

2.  Usefulness of three-dimensional echocardiographic reconstruction of the Amplatzer septal occluder in patients undergoing atrial septal closure.

Authors:  Mauro Pepi; Gloria Tamborini; Antonio Luca Bartorelli; Daniela Trabattoni; Anna Maltagliati; Stefano De Vita; Daniele Andreini; Gianluca Pontone
Journal:  Am J Cardiol       Date:  2004-11-15       Impact factor: 2.778

3.  Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images.

Authors:  Cristiana Corsi; Roberto M Lang; Federico Veronesi; Lynn Weinert; Enrico G Caiani; Peter MacEneaney; Claudio Lamberti; Victor Mor-Avi
Journal:  Circulation       Date:  2005-08-15       Impact factor: 29.690

Review 4.  Percutaneous balloon aortic valvuloplasty revisited: time for a renaissance?

Authors:  Hidehiko Hara; Wesley R Pedersen; Elena Ladich; Michael Mooney; Renu Virmani; Masato Nakamura; Ted Feldman; Robert S Schwartz
Journal:  Circulation       Date:  2007-03-27       Impact factor: 29.690

5.  A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results.

Authors:  L Gepstein; G Hayam; S A Ben-Haim
Journal:  Circulation       Date:  1997-03-18       Impact factor: 29.690

6.  Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography.

Authors:  A Franke; H P Kühl; D Rulands; C Jansen; C Erena; R G Grabitz; S Däbritz; B J Messmer; F A Flachskampf; P Hanrath
Journal:  Circulation       Date:  1997-11-04       Impact factor: 29.690

7.  Radiation exposure during catheter ablation of atrial fibrillation.

Authors:  Lars Lickfett; Mahadevappa Mahesh; Chandra Vasamreddy; David Bradley; Vinod Jayam; Zayd Eldadah; Timm Dickfeld; Deborah Kearney; Darshan Dalal; Berndt Lüderitz; Ronald Berger; Hugh Calkins
Journal:  Circulation       Date:  2004-10-25       Impact factor: 29.690

8.  A hybrid approach for quantification of aortic valve stenosis using cardiac magnetic resonance imaging and echocardiography: comparison to right heart catheterization and standard echocardiography.

Authors:  D Haghi; T Suselbeck; S Fluechter; G Kalmar; M Schroder; J J Kaden; T Poerner; M Borggrefe; T Papavassiliu
Journal:  Clin Res Cardiol       Date:  2006-02-13       Impact factor: 5.460

9.  Percutaneous mitral valve repair for chronic ischemic mitral regurgitation: a real-time three-dimensional echocardiographic study in an ovine model.

Authors:  Masao Daimon; Takahiro Shiota; A Marc Gillinov; Motoya Hayase; Marc Ruel; William E Cohn; Steven J Blacker; John R Liddicoat
Journal:  Circulation       Date:  2005-04-25       Impact factor: 29.690

10.  Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology: feasibility study.

Authors:  Eric C Pua; Salim F Idriss; Patrick D Wolf; S W Smith
Journal:  Ultrason Imaging       Date:  2007-07       Impact factor: 1.578

View more
  13 in total

1.  Non-compaction cardiomyopathy of the left ventricle diagnosed by cardiac magnetic resonance in a 2-generation family.

Authors:  Grigorios Korosoglou; Philipp Ehlermann; Derliz Mereles; Evangelos Giannitsis; Hugo A Katus
Journal:  Clin Res Cardiol       Date:  2010-09-07       Impact factor: 5.460

2.  Percutaneous closure of complex atrial septum defect guided by real-time 3D transesophageal echocardiography.

Authors:  F Dodos; Uta C Hoppe
Journal:  Clin Res Cardiol       Date:  2009-05-13       Impact factor: 5.460

3.  Real-time three-dimensional transoesophageal echocardiography: a new intraoperative feasible and useful technology in cardiac surgery.

Authors:  Paola Gripari; Gloria Tamborini; Paolo Barbier; Anna C Maltagliati; Claudia A Galli; Manuela Muratori; Luca Salvi; Erminio Sisillo; Francesco Alamanni; Mauro Pepi
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-30       Impact factor: 2.357

4.  Transapical septal occluder for paravalvular leakage of the mitral valve: a novel method for interventional treatment in high-risk patients.

Authors:  Karim Ibrahim; Marian Christoph; Joachim Nicolai; Hagen Schroetter; Thorsten Schmidt; Utz Kappert; Steffen Schoen; Ruth H Strasser
Journal:  Clin Res Cardiol       Date:  2011-06-05       Impact factor: 5.460

5.  Optimized guidance of percutaneous edge-to edge repair of the mitral valve using real-time 3-D transesophageal echocardiography.

Authors:  Ertunc Altiok; Michael Becker; Sandra Hamada; Sebastian Reith; Nikolaus Marx; Rainer Hoffmann
Journal:  Clin Res Cardiol       Date:  2011-03-03       Impact factor: 5.460

6.  Beat to beat 3-dimensional intracardiac echocardiography: theoretical approach and practical experiences.

Authors:  Daniel Stapf; Andreas Franke; Marcus Schreckenberg; Georg Schummers; Karl Mischke; Nikolaus Marx; Patrick Schauerte; Christian Knackstedt
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-14       Impact factor: 2.357

Review 7.  Patent foramen ovale: anatomical complexity and long-tunnel morphology related issues.

Authors:  Giampiero Vizzari; Fausto Pizzino; Dianne Zwicke; A Jamil Tajik; Scipione Carerj; Gianluca Di Bella; Antonio Micari; Bijoy K Khandheria; Concetta Zito
Journal:  Am J Cardiovasc Dis       Date:  2021-06-15

8.  Passive markers for tracking surgical instruments in real-time 3-D ultrasound imaging.

Authors:  Jeffrey Stoll; Hongliang Ren; Pierre E Dupont
Journal:  IEEE Trans Med Imaging       Date:  2011-10-25       Impact factor: 10.048

9.  Sustained risk of recurrent thromboembolic events in patients with patent foramen ovale and paradoxical embolism: long-term follow-up over more than 15 years.

Authors:  Dieter Fischer; Ajmal Gardiwal; Jonas Haentjes; Gunnar Klein; Gerd-Peter Meyer; Helmut Drexler; Dirk Hausmann; Arnd Schaefer
Journal:  Clin Res Cardiol       Date:  2011-12-10       Impact factor: 5.460

Review 10.  Robotics and imaging in congenital heart surgery.

Authors:  Nikolay V Vasilyev; Pierre E Dupont; Pedro J del Nido
Journal:  Future Cardiol       Date:  2012-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.