Literature DB >> 23065102

Beat to beat 3-dimensional intracardiac echocardiography: theoretical approach and practical experiences.

Daniel Stapf1, Andreas Franke, Marcus Schreckenberg, Georg Schummers, Karl Mischke, Nikolaus Marx, Patrick Schauerte, Christian Knackstedt.   

Abstract

Three-dimensional (3D)-imaging provides important information on cardiac anatomy during electrophysiological procedures. Real-time updates of modalities with high soft-tissue contrast are particularly advantageous during cardiac procedures. Therefore, a beat to beat 3D visualization of cardiac anatomy by intracardiac echocardiography (ICE) was developed and tested in phantoms and animals. An electronic phased-array 5-10 MHz ICE-catheter (Acuson, AcuNav/Siemens Medical Solutions USA/64 elements) providing a 90° sector image was used for ICE-imaging. A custom-made mechanical prototype controlled by a servo motor allowed automatic rotation of the ICE-catheter around its longitudinal axis. During a single heartbeat, the ICE-catheter was rotated and 2D-images were acquired. Reconstruction into a 3D volume and rendering by a prototype software was performed beat to beat. After experimental validation using a rigid phantom, the system was tested in an animal study and afterwards, for quantitative validation, in a dynamic phantom. Acquisition of beat to beat 3D-reconstruction was technically feasible. However, twisting of the ICE-catheter shaft due to friction and torsion was found and rotation was hampered. Also, depiction of catheters was not always ensured in case of parallel alignment. Using a curved sheath for depiction of cardiac anatomy there was no congruent depiction of shape and dimension of static and moving objects. Beat to beat 3D-ICE-imaging is feasible. However, shape and dimension of static and moving objects cannot always be displayed with necessary steadiness as needed in the clinical setting. As catheter depiction is also limited, clinical use seems impossible.

Mesh:

Year:  2012        PMID: 23065102     DOI: 10.1007/s10554-012-0136-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  31 in total

1.  Anatomic and hemodynamic imaging using a new vector phased-array intracardiac catheter.

Authors:  Peng Li; Ismail T Dairywala; Zheng Liu; Scott R Stewart; Biju Mathew; Dana Bowie; Mani A Vannan
Journal:  J Am Soc Echocardiogr       Date:  2002-04       Impact factor: 5.251

2.  Effects of septal pacing on P wave characteristics: the value of three-dimensional echocardiography.

Authors:  Tamas Szili-Torok; Nico Bruining; Marcoen Scholten; Geert-Jan Kimman; Jos Roelandt; Luc Jordaens
Journal:  Pacing Clin Electrophysiol       Date:  2003-01       Impact factor: 1.976

3.  Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time.

Authors:  Timm Dickfeld; Hugh Calkins; Muz Zviman; Ritsushi Kato; Glenn Meininger; Lars Lickfett; Ron Berger; Henry Halperin; Stephen B Solomon
Journal:  Circulation       Date:  2003-10-20       Impact factor: 29.690

4.  Use of intracardiac echocardiography in guiding radiofrequency catheter ablation of atrial tachycardia in a patient after the senning operation.

Authors:  Anita Kedia; Pamela Y F Hsu; Joanna Holmes; Dee Burnham; Gail West; Fred M Kusumoto
Journal:  Pacing Clin Electrophysiol       Date:  2003-11       Impact factor: 1.976

5.  Interatrial septum pacing guided by three-dimensional intracardiac echocardiography.

Authors:  Tamas Szili-Torok; Geert Jan P Kimman; Marcoen F Scholten; Jurgen Ligthart; Nico Bruining; Dominic A M J Theuns; Peter J Klootwijk; Jos R T C Roelandt; Luc J Jordaens
Journal:  J Am Coll Cardiol       Date:  2002-12-18       Impact factor: 24.094

6.  Radiofrequency catheter ablation of paroxysmal atrial fibrillation; guidance by intracardiac echocardiography and integration with other imaging techniques.

Authors:  M R M Jongbloed; J J Bax; N M S de Groot; M S Dirksen; H J Lamb; A de Roos; E E van der Wall; M J Schalij
Journal:  Eur J Echocardiogr       Date:  2003-03

Review 7.  Use of imaging techniques to guide catheter ablation procedures.

Authors:  Melissa R Robinson; Mathew D Hutchinson
Journal:  Curr Cardiol Rep       Date:  2010-09       Impact factor: 2.931

8.  Relationship between anatomic location of the crista terminalis and double potentials recorded during atrial flutter: intracardiac echocardiographic analysis.

Authors:  Yasuo Okumura; Ichiro Watanabe; Takeshi Yamada; Kimie Ohkubo; Hidezou Sugimura; Kenichi Hashimoto; Tatsuya Kofune; Yasuhiro Takagi; Rie Wakita; Naohiro Oshikawa; Kazunori Kawauchi; Satoshi Saito; Yukio Ozawa; Katsuo Kanmatsuse; Yasuyuki Yoshikawa; Yuko Asakawa
Journal:  J Cardiovasc Electrophysiol       Date:  2004-12

9.  Real-time integration of intracardiac echocardiography and 3D electroanatomical mapping to guide catheter ablation of isthmus-dependent atrial flutter in a patient with complete situs inversus and interruption of the inferior vena cava with azygos continuation.

Authors:  Giovanni B Forleo; Augusto Pappalardo; Andrea Avella; Lidia Visigalli; Antonio Dello Russo; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2009-08-08       Impact factor: 1.900

10.  Image integration using intracardiac ultrasound to guide catheter ablation of atrial fibrillation.

Authors:  Sheldon M Singh; E Kevin Heist; David M Donaldson; Ryan M Collins; Jianping Chevalier; Theofanie Mela; Jeremy N Ruskin; Moussa C Mansour
Journal:  Heart Rhythm       Date:  2008-08-29       Impact factor: 6.343

View more
  1 in total

Review 1.  Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2014-04       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.