Literature DB >> 18509628

Long-term results with Matrix coils vs. GDC: an angiographic and histopathological comparison.

C Roth1, T Struffert, I Q Grunwald, B F M Romeike, C Krick, P Papanagiotou, P Krampe, W Reith.   

Abstract

INTRODUCTION: The aim of the study was to compare standard platinum Guglielmi detachable coils (GDC) with coated platinum coils (Matrix; both Boston Scientific, Fremont, CA) regarding handling, complications, occlusion and recanalization rate after 3 and 6A months.
METHODS: Aneurysms in the right common carotid artery were created in 25 rabbits. The animals were divided into five groups of five animals each. The animals of group 1 (the control group) received no treatment of the induced aneurysms, the animals of groups 2 and 3 (killed at 3 and 6A months) were treated with standard GDC, and the animals of groups 4 and 5 (killed at 3 and 6A months) were treated with Matrix coils.
RESULTS: Histopathological evaluation showed organized thrombus formation and connective tissue with neovascularization around the implanted coils in all the treated groups. The achieved occlusion rates in groups 2 and 3 were identical to those in groups 4 and 5. Thus the long-term results of aneurysm treatment with GDC and Matrix coils show no differences regarding occlusion and recanalization rates. The only noticeable difference was the difference in handling. More force was required to pushing the Matrix coils forward through the microcatheter and there was more friction in coil interaction in the aneurysm.
CONCLUSION: The bioactive coating of the Matrix coil produces no significant benefit in achieving higher occlusion and lower recanalization rates, and the coil is more difficult to handle. Future bioactive coils must be shown to produce significantly better long-term results than GDC and their ease of handling has to be improved.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18509628     DOI: 10.1007/s00234-008-0392-8

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  27 in total

1.  Matrix detachable coils for the endovascular treatment of intracranial aneurysms: analysis of early angiographic and clinical outcomes.

Authors:  Christian A Taschner; Xavier Leclerc; Henda Rachdi; Alexander Maia Barros; Jean-Pierre Pruvo
Journal:  Stroke       Date:  2005-09-08       Impact factor: 7.914

2.  Short-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer-coated coils compared to historical controls treated with bare platinum coils: a single-center experience.

Authors:  Hyun-Seung Kang; Moon Hee Han; Bae Ju Kwon; O-Ki Kwon; Sung Hyun Kim; Seung Hong Choi; Kee-Hyun Chang
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

3.  Endovascular creation of an in vivo bifurcation aneurysm model in rabbits.

Authors:  H J Cloft; T A Altes; W F Marx; R J Raible; S B Hudson; G A Helm; J W Mandell; M E Jensen; J E Dion; D F Kallmes
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

4.  Intra-venous digital subtraction angiography: an alternative method to intra-arterial digital subtraction angiography for experimental aneurysm imaging.

Authors:  Yong Hong Ding; Daying Dai; Debra A Lewis; Mark A Danielson; Ramanathan Kadirvel; Jayawant N Mandrekar; Harry J Cloft; David F Kallmes
Journal:  Neuroradiology       Date:  2005-08-25       Impact factor: 2.804

5.  Anticoagulation regimes and their influence on the occlusion rate of aneurysms: an experimental study in rabbits.

Authors:  Iris Quasar Grunwald; Bernd F M Romeike; Christian Roth; Tobias Struffert; Regina Eymann; Wolfgang Reith
Journal:  Neurosurgery       Date:  2005-11       Impact factor: 4.654

6.  Endovascular treatment of unruptured intracranial aneurysms: occurrence of thromboembolic events.

Authors:  Iris Quasar Grunwald; Panagiotis Papanagiotou; Maria Politi; Tobias Struffert; Christian Roth; Wolfgang Reith
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

7.  Intracranial aneurysms: endovascular treatment with mechanical detachable spirals in 60 aneurysms.

Authors:  C Cognard; L Pierot; A Boulin; A Weill; M Tovi; L Castaings; A Rey; J Moret; M Toevi
Journal:  Radiology       Date:  1997-03       Impact factor: 11.105

8.  Recanalization after endovascular treatment of intracerebral aneurysms.

Authors:  Iris Q Grunwald; Panagiotis Papanagiotou; Tobias Struffert; Maria Politi; Christoph Krick; Gökmen Gül; Wolfgang Reith
Journal:  Neuroradiology       Date:  2006-11-09       Impact factor: 2.804

9.  Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils.

Authors:  Menno Sluzewski; Willem Jan van Rooij; Marian J Slob; Javier Oliván Bescós; Cornelis H Slump; Douwe Wijnalda
Journal:  Radiology       Date:  2004-04-29       Impact factor: 11.105

10.  Endovascular coiling of intracranial aneurysms using bioactive coils: a single-center study.

Authors:  S Rossitti
Journal:  Acta Radiol       Date:  2007-06       Impact factor: 1.990

View more
  5 in total

Review 1.  In vivo experimental intracranial aneurysm models: a systematic review.

Authors:  F Bouzeghrane; O Naggara; D F Kallmes; A Berenstein; J Raymond
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-29       Impact factor: 3.825

Review 2.  The Past, Present and Future of Endovascular Aneurysm Treatment.

Authors:  H Henkes; W Weber
Journal:  Clin Neuroradiol       Date:  2015-06-02       Impact factor: 3.649

3.  Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms.

Authors:  I-Chang Su; Robert A Willinsky; Noel F Fanning; Ronit Agid
Journal:  Neuroradiology       Date:  2014-03-28       Impact factor: 2.804

4.  Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent.

Authors:  Tobias Struffert; Sabine Ott; Markus Kowarschik; Frederik Bender; Edyta Adamek; Tobias Engelhorn; Philipp Gölitz; Stefan Lang; Charles M Strother; Arnd Doerfler
Journal:  Eur Radiol       Date:  2012-08-16       Impact factor: 5.315

Review 5.  Coil type does not affect angiographic follow-up outcomes of cerebral aneurysm coiling: a systematic review and meta-analysis.

Authors:  I Rezek; G Mousan; Z Wang; M H Murad; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-09       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.