Literature DB >> 16151028

Matrix detachable coils for the endovascular treatment of intracranial aneurysms: analysis of early angiographic and clinical outcomes.

Christian A Taschner1, Xavier Leclerc, Henda Rachdi, Alexander Maia Barros, Jean-Pierre Pruvo.   

Abstract

BACKGROUND AND
PURPOSE: Endovascular coil embolization has become an accepted alternative for the treatment of intracranial aneurysms. The purpose of this study was to evaluate the clinical safety and the angiographic stability of aneurysm occlusion with a new class of biologically active platinum coils after a 6-month period.
METHODS: Twenty-five patients with 25 intracranial aneurysms were treated by selective embolization with a new coated bioactive coil (Matrix; Boston Scientific Neurovascular). Matrix coils were used alone in 6 patients and in combination with Guglielmi detachable coils (GDCs; Boston Scientific Neurovascular) in 19. Angiographic results, procedure-related complications, and adverse neurological events during the follow-up period were recorded. Magnetic resonance angiography was performed at 6 months in all patients.
RESULTS: Initial angiographies demonstrated complete occlusion in 17 patients, residual neck in 7, and a persisting aneurysm in 1. The clinical follow-up showed stable results in all patients. The grade of aneurysm occlusion at 6 months improved in 4 patients, remained stable in 15, and deteriorated in 6. Three patients needed retreatment because of a major aneurysm recanalization. Angiographic recurrences in cases of aneurysms treated with a combination of Matrix coils and GDCs occurred within the expected range for bare platinum coils. Two of 3 patients needing retreatment had been treated with Matrix coils alone.
CONCLUSIONS: Stable results were obtained predominantly when Matrix coils were combined with bare platinum coils. A prospective, randomized study is necessary to assess the potential benefit of Matrix coils for patients treated by endovascular techniques.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16151028     DOI: 10.1161/01.STR.0000181770.14869.ce

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  24 in total

1.  Bare, bio-active and hydrogel-coated coils for endovascular treatment of experimentally induced aneurysms. Long-term histological and scanning electron microscopy results.

Authors:  M H T Reinges; T Krings; A Y Drexler; A Ludolph; B Sellhaus; M Bovi; S Geibprasert; R Agid; K Scherer; F J Hans
Journal:  Interv Neuroradiol       Date:  2010-07-19       Impact factor: 1.610

2.  Cerecyte coils in the treatment of intracranial aneurysms: a preliminary clinical study.

Authors:  M Bendszus; L Solymosi
Journal:  AJNR Am J Neuroradiol       Date:  2006 Nov-Dec       Impact factor: 3.825

3.  Endovascular treatment of intracranial aneurysms with matrix coils: immediate posttreatment results, clinical outcome and follow-up.

Authors:  T Jonas Kimchi; R A Willinsky; J Spears; S K Lee; K ter Brugge
Journal:  Neuroradiology       Date:  2007-01-03       Impact factor: 2.804

4.  Matrix reloaded.

Authors:  H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2007-10-09       Impact factor: 3.825

Review 5.  Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?

Authors:  W Kurre; J Berkefeld
Journal:  Neuroradiology       Date:  2008-09-19       Impact factor: 2.804

Review 6.  Advances in Biomaterials and Technologies for Vascular Embolization.

Authors:  Jingjie Hu; Hassan Albadawi; Brian W Chong; Amy R Deipolyi; Rahul A Sheth; Ali Khademhosseini; Rahmi Oklu
Journal:  Adv Mater       Date:  2019-06-06       Impact factor: 30.849

7.  Effect of endovascular treatment on headache in elderly patients with unruptured intracranial aneurysms.

Authors:  D-Q Gu; C-Z Duan; X-F Li; X-Y He; L-F Lai; S-X Su
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-06       Impact factor: 3.825

8.  Gellan sulfate core platinum coil with tenascin-C promotes intra-aneurysmal organization in rats.

Authors:  Kazuhide Hamada; Yoichi Miura; Naoki Toma; Keiichi Miyamoto; Kyoko Imanaka-Yoshida; Satoshi Matsushima; Toshimichi Yoshida; Waro Taki; Hidenori Suzuki
Journal:  Transl Stroke Res       Date:  2014-06-19       Impact factor: 6.829

9.  Angiographic and histological comparison of canine bifurcation aneurysms treated with first generation matrix and standard GDC coils.

Authors:  Aquilla S Turk; Christopher M Luty; Victoria Carr-Brendel; Igor Polyakov; Dan Consigny; Julie Grinde; Rajat Mukherjee; Charles M Strother
Journal:  Neuroradiology       Date:  2007-09-27       Impact factor: 2.804

10.  GDC 360 degrees for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D Coils in 38 patients.

Authors:  Christian A Taschner; Laurent Thines; Mohamed El-Mahdy; Henda Rachdi; Jean-Yves Gauvrit; Jean-Paul Lejeune; Jean-Pierre Pruvo; Xavier Leclerc
Journal:  Neuroradiology       Date:  2008-10-14       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.