Literature DB >> 18504591

MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging.

Laurent Huwart1, Najat Salameh, Leon ter Beek, Eric Vicaut, Frank Peeters, Ralph Sinkus, Bernard E Van Beers.   

Abstract

The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 +/- 5.37 for spin-echo versus 21.02 +/- 4.76 for echo-planar, p = 0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r = 0.91 (p < 0.01) with spin-echo and r = 0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p = 0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r = 0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18504591     DOI: 10.1007/s00330-008-1051-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  Pain experienced during percutaneous liver biopsy.

Authors:  L Castéra; I Nègre; K Samii; C Buffet
Journal:  Hepatology       Date:  1999-12       Impact factor: 17.425

Review 2.  Appropriateness of liver biopsy.

Authors:  T Poynard; V Ratziu; P Bedossa
Journal:  Can J Gastroenterol       Date:  2000-06       Impact factor: 3.522

Review 3.  Correlation and simple linear regression.

Authors:  Kelly H Zou; Kemal Tuncali; Stuart G Silverman
Journal:  Radiology       Date:  2003-06       Impact factor: 11.105

4.  Fractional encoding of harmonic motions in MR elastography.

Authors:  Jens Rump; Dieter Klatt; Jürgen Braun; Carsten Warmuth; Ingolf Sack
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

5.  Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C.

Authors:  Laurent Castéra; Julien Vergniol; Juliette Foucher; Brigitte Le Bail; Elise Chanteloup; Maud Haaser; Monique Darriet; Patrice Couzigou; Victor De Lédinghen
Journal:  Gastroenterology       Date:  2005-02       Impact factor: 22.682

6.  Accuracy of liver stiffness measurement for the diagnosis of cirrhosis in patients with chronic liver diseases.

Authors:  Nathalie Ganne-Carrié; Marianne Ziol; Victor de Ledinghen; Catherine Douvin; Patrick Marcellin; Laurent Castera; Daniel Dhumeaux; Jean-Claude Trinchet; Michel Beaugrand
Journal:  Hepatology       Date:  2006-12       Impact factor: 17.425

7.  Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study.

Authors:  J Foucher; E Chanteloup; J Vergniol; L Castéra; B Le Bail; X Adhoute; J Bertet; P Couzigou; V de Lédinghen
Journal:  Gut       Date:  2005-07-14       Impact factor: 23.059

8.  MR elastography of the liver: preliminary results.

Authors:  Olivier Rouvière; Meng Yin; M Alex Dresner; Phillip J Rossman; Lawrence J Burgart; Jeff L Fidler; Richard L Ehman
Journal:  Radiology       Date:  2006-08       Impact factor: 11.105

9.  In vivo determination of hepatic stiffness using steady-state free precession magnetic resonance elastography.

Authors:  Dieter Klatt; Patrick Asbach; Jens Rump; Sebastian Papazoglou; Rajan Somasundaram; Jens Modrow; Jürgen Braun; Ingolf Sack
Journal:  Invest Radiol       Date:  2006-12       Impact factor: 6.016

10.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis.

Authors:  Laurent Sandrin; Bertrand Fourquet; Jean-Michel Hasquenoph; Sylvain Yon; Céline Fournier; Frédéric Mal; Christos Christidis; Marianne Ziol; Bruno Poulet; Farad Kazemi; Michel Beaugrand; Robert Palau
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

View more
  28 in total

Review 1.  General review of magnetic resonance elastography.

Authors:  Gavin Low; Scott A Kruse; David J Lomas
Journal:  World J Radiol       Date:  2016-01-28

Review 2.  Magnetic resonance elastography: a general overview of its current and future applications in brain imaging.

Authors:  Antonio Di Ieva; Fabio Grizzi; Elisa Rognone; Zion Tsz Ho Tse; Tassanai Parittotokkaporn; Ferdinando Rodriguez Y Baena; Manfred Tschabitscher; Christian Matula; Siegfrid Trattnig; Riccardo Rodriguez Y Baena
Journal:  Neurosurg Rev       Date:  2010-02-27       Impact factor: 3.042

3.  Technical Failure of MR Elastography Examinations of the Liver: Experience from a Large Single-Center Study.

Authors:  Mathilde Wagner; Idoia Corcuera-Solano; Grace Lo; Steven Esses; Joseph Liao; Cecilia Besa; Nelson Chen; Ginu Abraham; Maggie Fung; James S Babb; Richard L Ehman; Bachir Taouli
Journal:  Radiology       Date:  2017-01-03       Impact factor: 11.105

Review 4.  Magnetic resonance elastography: basic principles, technique, and clinical applications in the liver.

Authors:  Habip Eser Akkaya; Ayşe Erden; Diğdem Kuru Öz; Sena Ünal; İlhan Erden
Journal:  Diagn Interv Radiol       Date:  2018-11       Impact factor: 2.630

5.  Editorial: A New Spin on Magnetic Resonance Elastography.

Authors:  Rekha Kishore; Rohit Loomba; Richard K Sterling
Journal:  Am J Gastroenterol       Date:  2016-06       Impact factor: 10.864

6.  Accuracy of MR elastography and anatomic MR imaging features in the diagnosis of severe hepatic fibrosis and cirrhosis.

Authors:  Rahul Rustogi; Jeanne Horowitz; Carla Harmath; Yi Wang; Hamid Chalian; Daniel R Ganger; Zongming E Chen; Bradley D Bolster; Saurabh Shah; Frank H Miller
Journal:  J Magn Reson Imaging       Date:  2012-01-13       Impact factor: 4.813

7.  Comparison of diagnostic accuracies of two- and three-dimensional MR elastography of the liver.

Authors:  Hiroyuki Morisaka; Utaroh Motosugi; Kevin J Glaser; Shintaro Ichikawa; Richard L Ehman; Katsuhiro Sano; Tomoaki Ichikawa; Hiroshi Onishi
Journal:  J Magn Reson Imaging       Date:  2016-09-23       Impact factor: 4.813

Review 8.  Magnetic resonance elastography of abdomen.

Authors:  Sudhakar Kundapur Venkatesh; Richard L Ehman
Journal:  Abdom Imaging       Date:  2015-04

Review 9.  Abdominal magnetic resonance elastography.

Authors:  Meng Yin; Jun Chen; Kevin J Glaser; Jayant A Talwalkar; Richard L Ehman
Journal:  Top Magn Reson Imaging       Date:  2009-04

Review 10.  Magnetic resonance elastography of liver: technique, analysis, and clinical applications.

Authors:  Sudhakar K Venkatesh; Meng Yin; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2013-03       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.