Literature DB >> 16864671

MR elastography of the liver: preliminary results.

Olivier Rouvière1, Meng Yin, M Alex Dresner, Phillip J Rossman, Lawrence J Burgart, Jeff L Fidler, Richard L Ehman.   

Abstract

PURPOSE: To develop a method for measuring liver stiffness with magnetic resonance (MR) elastography and to prospectively test this technique in healthy volunteers and patients with liver fibrosis.
MATERIALS AND METHODS: This HIPAA-compliant study was approved by an institutional review board, and informed consent was obtained from each subject. First, to determine the feasibility of applying shear waves to the liver, a pneumatic acoustic wave generator was developed and tested by using a tissue-simulating gel phantom with ribs on one side and without ribs on the other. The effect of interposed ribs on stiffness measurements was tested. Then, liver stiffness was measured with MR elastography in 12 healthy volunteers (eight men, four women; mean age, 26.7 years; age range, 19-39 years) by using the subcostal approach and the transcostal approach and in 12 patients with chronic liver disease (six men, six women; mean age, 50.5 years; age range, 36-60 years) by using the transcostal approach. Various statistical analyses were performed to assess all measurements.
RESULTS: Ex vivo, interposed ribs reduced shear wave amplitude but did not hinder stiffness measurements. In volunteers, the transcostal approach surprisingly yielded better shear waves in the liver than did the subcostal approach. The mean liver shear stiffness was significantly lower in volunteers (mean, 2.0 kPa +/- 0.3 [standard deviation]) than it was in patients with liver fibrosis (mean, 5.6 kPa +/- 5.0; median, 3.7 kPa; range, 2.7-19.2 kPa; P < .001).
CONCLUSION: MR elastography of the liver is feasible and shows promise as a quantitative method for noninvasive assessment of liver fibrosis. RSNA, 2006

Entities:  

Mesh:

Year:  2006        PMID: 16864671     DOI: 10.1148/radiol.2402050606

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  132 in total

1.  Effects of gadoxetic acid on liver elasticity measurement by using magnetic resonance elastography.

Authors:  Utaroh Motosugi; Tomoaki Ichikawa; Hironobu Sou; Katsuhiro Sano; Ali Muhi; Richard L Ehman; Tsutomu Araki
Journal:  Magn Reson Imaging       Date:  2011-09-19       Impact factor: 2.546

2.  Utility of diffusion-weighted imaging in the evaluation of liver fibrosis.

Authors:  Ayse Ahsen Bakan; Ercan Inci; Selim Bakan; Suut Gokturk; Tan Cimilli
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

3.  Acoustic radiation force impulse elastography of the liver: can fat deposition in the liver affect the measurement of liver stiffness?

Authors:  Utaroh Motosugi; Tomoaki Ichikawa; Yoshibumi Niitsuma; Tsutomu Araki
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

4.  Contrast detection in fluid-saturated media with magnetic resonance poroelastography.

Authors:  Phillip R Perriñez; Adam J Pattison; Francis E Kennedy; John B Weaver; Keith D Paulsen
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

5.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

6.  Deterministically patterned biomimetic human iPSC-derived hepatic model via rapid 3D bioprinting.

Authors:  Xuanyi Ma; Xin Qu; Wei Zhu; Yi-Shuan Li; Suli Yuan; Hong Zhang; Justin Liu; Pengrui Wang; Cheuk Sun Edwin Lai; Fabian Zanella; Gen-Sheng Feng; Farah Sheikh; Shu Chien; Shaochen Chen
Journal:  Proc Natl Acad Sci U S A       Date:  2016-02-08       Impact factor: 11.205

Review 7.  General review of magnetic resonance elastography.

Authors:  Gavin Low; Scott A Kruse; David J Lomas
Journal:  World J Radiol       Date:  2016-01-28

8.  Effect of branched-chain amino acid supplementation on insulin resistance and quality of life in chronic hepatitis C patients.

Authors:  Alicia Ocaña-Mondragón; José Antonio Mata-Marín; Mario Uriarte-López; Carolina Bekker-Méndez; Enrique Alcalá-Martínez; Rosa María Ribas-Aparicio; Luis Antonio Uribe-Noguéz; Dulce María Rodríguez-Galindo; María de La Luz Martínez-Rodríguez
Journal:  Biomed Rep       Date:  2017-11-03

9.  Comparison of diagnostic accuracies of two- and three-dimensional MR elastography of the liver.

Authors:  Hiroyuki Morisaka; Utaroh Motosugi; Kevin J Glaser; Shintaro Ichikawa; Richard L Ehman; Katsuhiro Sano; Tomoaki Ichikawa; Hiroshi Onishi
Journal:  J Magn Reson Imaging       Date:  2016-09-23       Impact factor: 4.813

Review 10.  Magnetic resonance elastography of abdomen.

Authors:  Sudhakar Kundapur Venkatesh; Richard L Ehman
Journal:  Abdom Imaging       Date:  2015-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.