Literature DB >> 18503429

Sex- and site-dependent variations in the thickness and mechanical properties of human skin in vivo.

S Diridollou1, D Black, J M Lagarde, Y Gall, M Berson, V Vabre, F Patat, L Vaillant.   

Abstract

A new method for the in vivo characterization of the physical properties of skin is presented. This comprises an ultrasound device to measure the vertical displacement of the surface of the skin, as well as its thickness and that of the hypodermis under suction. In combination with this, a mathematical model is used to calculate the following skin parameters: Young's modulus, the initial stress and an index of non-elasticity. These parameters were evaluated from the volar forearm and the forehead of 30 male and 30 females, of similar ages (28 +/- 6-years-old). The sensitivity of the testing procedure, allowing the characterization of the mechanical parameters of the skin, easily differentiated these two sites, and in some cases, differences between women and men were demonstrated. The main results showed for both sexes that the thickness (P = 0.0001), Young's modulus (P = 0.0001), and the index of non-elasticity (P = 0.0001) were greater for the forehead than for the ventral forearm, but that the initial stress was lower (P = 0.0001). The results show that the skin is thicker, stiffer and less tense and elastic on the forehead than on the ventral forearm, suggesting structural differences between these two sites (collagen fibre network, elastic fibres, epidermis, stratum corneum, microvascularization, actinic damage, presence of sebaceous glands, etc.). It is hoped that this device will be useful for the evaluation of certain skin disorders (scleroderma, Ehlers-Danlos syndrome, cutis laxa, oedema, etc.) and their therapy, as well as being a useful tool in skin ageing and cosmetic product assessment.

Entities:  

Year:  2000        PMID: 18503429

Source DB:  PubMed          Journal:  Int J Cosmet Sci        ISSN: 0142-5463            Impact factor:   2.970


  12 in total

1.  Cutaneous resonance running time varies with age, body site and gender in a normal Chinese population.

Authors:  Shujun Xin; Wenyan Man; Joachim W Fluhr; Shunpeng Song; Peter M Elias; Mao-Qiang Man
Journal:  Skin Res Technol       Date:  2010-11       Impact factor: 2.365

2.  The analysis of forces needed for the suturing of elliptical skin wounds.

Authors:  Lukas Capek; Emmanuelle Jacquet; Ladislav Dzan; Antonin Simunek
Journal:  Med Biol Eng Comput       Date:  2011-12-27       Impact factor: 2.602

Review 3.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

Review 4.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: examples and application.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

5.  Conformal piezoelectric systems for clinical and experimental characterization of soft tissue biomechanics.

Authors:  Canan Dagdeviren; Yan Shi; Pauline Joe; Roozbeh Ghaffari; Guive Balooch; Karan Usgaonkar; Onur Gur; Phat L Tran; Jessi R Crosby; Marcin Meyer; Yewang Su; R Chad Webb; Andrew S Tedesco; Marvin J Slepian; Yonggang Huang; John A Rogers
Journal:  Nat Mater       Date:  2015-05-18       Impact factor: 43.841

6.  Miniaturized electromechanical devices for the characterization of the biomechanics of deep tissue.

Authors:  Enming Song; Zhaoqian Xie; Wubin Bai; Haiwen Luan; Bowen Ji; Xin Ning; Yu Xia; Janice Mihyun Baek; Yujin Lee; Raudel Avila; Huang-Yu Chen; Jae-Hwan Kim; Surabhi Madhvapathy; Kuanming Yao; Dengfeng Li; Jingkun Zhou; Mengdi Han; Sang Min Won; Xinyuan Zhang; Daniel J Myers; Yongfeng Mei; Xu Guo; Shuai Xu; Jan-Kai Chang; Xinge Yu; Yonggang Huang; John A Rogers
Journal:  Nat Biomed Eng       Date:  2021-05-27       Impact factor: 25.671

Review 7.  Recent advances in microsystem approaches for mechanical characterization of soft biological tissues.

Authors:  Enming Song; Ya Huang; Ningge Huang; Yongfeng Mei; Xinge Yu; John A Rogers
Journal:  Microsyst Nanoeng       Date:  2022-07-07       Impact factor: 8.006

Review 8.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

9.  Biomechanical properties of in vivo human skin from dynamic optical coherence elastography.

Authors:  Xing Liang; Stephen A Boppart
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-09       Impact factor: 4.538

10.  Mechanical Behaviour of Silicone Membranes Saturated with Short Strand, Loose Polyester Fibres for Prosthetic and Rehabilitative Surrogate Skin Applications.

Authors:  Richard Arm; Arash Shahidi; Tilak Dias
Journal:  Materials (Basel)       Date:  2019-11-06       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.