Literature DB >> 18501569

Structure formation and characterization of injectable drug loaded biodegradable devices: in situ implants versus in situ microparticles.

H Kranz1, R Bodmeier.   

Abstract

The objective of the study was to investigate key formulation variables affecting the release of bupivacaine hydrochloride, a local anesthetic, from different in situ forming biodegradable drug delivery devices. The formulations included ISM systems [in situ microparticles, a poly(lactide)-solvent phase dispersed into an external oil phase] and poly(lactide) solutions (in situ implant systems). The solubility of the biodegradable polymer poly(d,l-lactide) (PLA) in various organic solvents was determined using the Hansen multicomponent solubility parameter concept. The solvent release from ISM and polymer solutions into phosphate buffer which influences the polymer precipitation rate was investigated as a function of the type of solvent, polymer concentration and polymer:oil phase ratio by using a HPLC assay. Scanning electron microscopy (SEM) was performed in order to relate the drug release to the surface properties of the precipitated implants or microparticles. Suitable solvents for the preparation of the in situ forming drug delivery systems, such as N-methyl-2-pyrrolidone (NMP), dimethylsulfoxide (DMSO) and 2-pyrrolidone were found using the Hansen multicomponent solubility parameter concept. The injection of the polymer solutions (in situ implants) into the aqueous medium led to a rapid solvent/non-solvent exchange. The resulting in situ implants were porous, thus explaining the rapid initial drug release. Upon contact with the release medium, the internal polymer phase of the ISM system solidified and formed microparticles as shown by SEM measurements. Due to the presence of an external oil phase the solvent release into the buffer medium from ISM was significantly slower compared to the polymer solutions. The solvent release of the ISM systems into the phosphate buffer decreased with increasing polymer concentration and decreasing polymer:oil phase ratio. The type of solvent used also affected the solvent release. A slower solvent release into the aqueous medium resulted in less porous microparticles, thus explaining the reduced initial drug release from ISM systems compared to the polymer solutions.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18501569     DOI: 10.1016/j.ejps.2008.03.004

Source DB:  PubMed          Journal:  Eur J Pharm Sci        ISSN: 0928-0987            Impact factor:   4.384


  21 in total

1.  A novel risperidone-loaded SAIB-PLGA mixture matrix depot with a reduced burst release: effects of solvents and PLGA on drug release behaviors in vitro/in vivo.

Authors:  Xia Lin; Shenshen Yang; Jingxin Gou; Mingming Zhao; Yu Zhang; Na Qi; Haibing He; Cuifang Cai; Xing Tang; Penghong Guo
Journal:  J Mater Sci Mater Med       Date:  2011-12-15       Impact factor: 3.896

2.  Improved Treatment of Pancreatic Cancer With Drug Delivery Nanoparticles Loaded With a Novel AKT/PDK1 Inhibitor.

Authors:  Joseph E Kobes; Iman Daryaei; Christine M Howison; Jordan G Bontrager; Rachael W Sirianni; Emmanuelle J Meuillet; Mark D Pagel
Journal:  Pancreas       Date:  2016-09       Impact factor: 3.327

3.  Ultrasound-guided intratumoral delivery of doxorubicin from in situ forming implants in a hepatocellular carcinoma model.

Authors:  Luis Solorio; Hanping Wu; Christopher Hernandez; Mihika Gangolli; Agata A Exner
Journal:  Ther Deliv       Date:  2016

4.  Improved small molecule drug release from in situ forming poly(lactic-co-glycolic acid) scaffolds incorporating poly(β-amino ester) and hydroxyapatite microparticles.

Authors:  Paul D Fisher; Pablo Palomino; Todd A Milbrandt; J Zach Hilt; David A Puleo
Journal:  J Biomater Sci Polym Ed       Date:  2014-06-06       Impact factor: 3.517

5.  Long-acting poly(DL:lactic acid-castor oil) 3:7-bupivacaine formulation: effect of hydrophobic additives.

Authors:  Marina Sokolsky-Papkov; Ludmila Golovanevski; Abraham J Domb; Carolyn F Weiniger
Journal:  Pharm Res       Date:  2011-06-30       Impact factor: 4.200

6.  Poly(lactide-co-glycolide) nanocapsules containing benzocaine: influence of the composition of the oily nucleus on physico-chemical properties and anesthetic activity.

Authors:  Nathalie Ferreira Silva de Melo; Renato Grillo; Viviane Aparecida Guilherme; Daniele Ribeiro de Araujo; Eneida de Paula; André Henrique Rosa; Leonardo Fernandes Fraceto
Journal:  Pharm Res       Date:  2011-04-07       Impact factor: 4.200

Review 7.  Newer Formulations of Risperidone: Role in the Management of Psychotic Disorders.

Authors:  Ivana Clark; David Taylor
Journal:  CNS Drugs       Date:  2020-08       Impact factor: 5.749

Review 8.  Significance of novel bioinorganic anodic aluminum oxide nanoscaffolds for promoting cellular response.

Authors:  Gérrard Eddy Jai Poinern; Robert Shackleton; Shariful Islam Mamun; Derek Fawcett
Journal:  Nanotechnol Sci Appl       Date:  2011-01-14

Review 9.  PLA micro- and nano-particles.

Authors:  Byung Kook Lee; Yeonhee Yun; Kinam Park
Journal:  Adv Drug Deliv Rev       Date:  2016-06-01       Impact factor: 15.470

10.  Noninvasive characterization of in situ forming implants using diagnostic ultrasound.

Authors:  Luis Solorio; Brett M Babin; Ravi B Patel; Justyna Mach; Nami Azar; Agata A Exner
Journal:  J Control Release       Date:  2010-01-11       Impact factor: 9.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.