Literature DB >> 18493856

Magnetron sputtered diamond-like carbon microelectrodes for on-chip measurement of quantal catecholamine release from cells.

Yuanfang Gao1, Xiaohui Chen, Sanju Gupta, Kevin D Gillis, Shubhra Gangopadhyay.   

Abstract

Carbon electrodes are widely used in electrochemistry due to their low cost, wide potential window, and low and stable background noise. Carbon-fiber electrodes (CFE) are commonly used to electrochemically measure "quantal" catecholamine release via exocytosis from individual cells, but it is difficult to integrate CFEs into lab-on-a-chip devices. Here we report the development of nitrogen doped diamond-like carbon (DLC:N) microelectrodes on a chip to monitor quantal release of catecholamines from cells. Advantages of DLC:N microelectrodes are that they are batch producible at low cost, and are harder and more durable than graphite films. The DLC:N microelectrodes were prepared by a magnetron sputtering process with nitrogen doping. The 30 microm by 40 microm DLC:N microelectrodes were patterned onto microscope glass slides by photolithography and lift-off technology. The properties of the DLC:N microelectrodes were characterized by AFM, Raman spectroscopy and cyclic voltammetry. Quantal catecholamine release was recorded amperometrically from bovine adrenal chromaffin cells on the DLC:N microelectrodes. Amperometric spikes due to quantal release of catecholamines were similar in amplitude and area as those recorded using CFEs and the background current and noise levels of microchip DLC:N electrodes were also comparable to CFEs. Therefore, DLC:N microelectrodes are suitable for microchip-based high-throughput measurement of quantal exocytosis with applications in basic research, drug discovery and cell-based biosensors.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18493856      PMCID: PMC2574730          DOI: 10.1007/s10544-008-9173-8

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  19 in total

1.  Microseparation chips for performing multienzymatic dehydrogenase/oxidase assays: simultaneous electrochemical measurement of ethanol and glucose.

Authors:  J Wang; M P Chatrathi; B Tian
Journal:  Anal Chem       Date:  2001-03-15       Impact factor: 6.986

2.  Automatic analysis for amperometrical recordings of exocytosis.

Authors:  F Segura; M A Brioso; J F Gómez; J D Machado; R Borges
Journal:  J Neurosci Methods       Date:  2000-11-30       Impact factor: 2.390

3.  Amperometric detection of quantal catecholamine secretion from individual cells on micromachined silicon chips.

Authors:  Peng Chen; Bai Xu; Natalya Tokranova; Xiaojun Feng; James Castracane; Kevin D Gillis
Journal:  Anal Chem       Date:  2003-02-01       Impact factor: 6.986

4.  Dynamic single-cell analysis for quantitative biology.

Authors:  Dino Di Carlo; Luke P Lee
Journal:  Anal Chem       Date:  2006-12-01       Impact factor: 6.986

5.  Diameter-Selective Raman Scattering from Vibrational Modes in Carbon Nanotubes

Authors: 
Journal:  Science       Date:  1997-01-10       Impact factor: 47.728

6.  On-chip amperometric measurement of quantal catecholamine release using transparent indium tin oxide electrodes.

Authors:  Xiuhua Sun; Kevin D Gillis
Journal:  Anal Chem       Date:  2006-04-15       Impact factor: 6.986

7.  Etched carbon-fiber electrodes as amperometric detectors of catecholamine secretion from isolated biological cells.

Authors:  K T Kawagoe; J A Jankowski; R M Wightman
Journal:  Anal Chem       Date:  1991-08-01       Impact factor: 6.986

8.  Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip.

Authors:  Jian Gao; Xue-Feng Yin; Zhao-Lun Fang
Journal:  Lab Chip       Date:  2003-10-29       Impact factor: 6.799

9.  Temporally resolved catecholamine spikes correspond to single vesicle release from individual chromaffin cells.

Authors:  R M Wightman; J A Jankowski; R T Kennedy; K T Kawagoe; T J Schroeder; D J Leszczyszyn; J A Near; E J Diliberto; O H Viveros
Journal:  Proc Natl Acad Sci U S A       Date:  1991-12-01       Impact factor: 11.205

10.  Phosphomimetic mutation of Ser-187 of SNAP-25 increases both syntaxin binding and highly Ca2+-sensitive exocytosis.

Authors:  Yan Yang; Tim J Craig; Xiaohui Chen; Leonora F Ciufo; Masami Takahashi; Alan Morgan; Kevin D Gillis
Journal:  J Gen Physiol       Date:  2007-03       Impact factor: 4.086

View more
  12 in total

1.  Transparent Electrode Materials for Simultaneous Amperometric Detection of Exocytosis and Fluorescence Microscopy.

Authors:  Kassandra Kisler; Brian N Kim; Xin Liu; Khajak Berberian; Qinghua Fang; Cherian J Mathai; Shubhra Gangopadhyay; Kevin D Gillis; Manfred Lindau
Journal:  J Biomater Nanobiotechnol       Date:  2012

2.  Microwell device for targeting single cells to electrochemical microelectrodes for high-throughput amperometric detection of quantal exocytosis.

Authors:  Xin Liu; Syed Barizuddin; Wonchul Shin; Cherian J Mathai; Shubhra Gangopadhyay; Kevin D Gillis
Journal:  Anal Chem       Date:  2011-02-28       Impact factor: 6.986

3.  Automated targeting of cells to electrochemical electrodes using a surface chemistry approach for the measurement of quantal exocytosis.

Authors:  Syed Barizuddin; Xin Liu; Joseph C Mathai; Maruf Hossain; Kevin D Gillis; Shubhra Gangopadhyay
Journal:  ACS Chem Neurosci       Date:  2010-07-01       Impact factor: 4.418

4.  Quantification of noise sources for amperometric measurement of quantal exocytosis using microelectrodes.

Authors:  Jia Yao; Kevin D Gillis
Journal:  Analyst       Date:  2012-04-27       Impact factor: 4.616

Review 5.  Electrochemical measurement of quantal exocytosis using microchips.

Authors:  Kevin D Gillis; Xin A Liu; Andrea Marcantoni; Valentina Carabelli
Journal:  Pflugers Arch       Date:  2017-09-02       Impact factor: 3.657

6.  Two approaches for addressing electrochemical electrode arrays with reduced external connections.

Authors:  J Yao; X A Liu; K D Gillis
Journal:  Anal Methods       Date:  2015-06-22       Impact factor: 2.896

7.  Preferential cell attachment to nitrogen-doped diamond-like carbon (DLC:N) for the measurement of quantal exocytosis.

Authors:  Atanu Sen; Syed Barizuddin; Maruf Hossain; Luis Polo-Parada; Kevin D Gillis; Shubhra Gangopadhyay
Journal:  Biomaterials       Date:  2009-01-04       Impact factor: 12.479

Review 8.  Surface-modified CMOS IC electrochemical sensor array targeting single chromaffin cells for highly parallel amperometry measurements.

Authors:  Meng Huang; Joannalyn B Delacruz; John C Ruelas; Shailendra S Rathore; Manfred Lindau
Journal:  Pflugers Arch       Date:  2017-09-09       Impact factor: 3.657

9.  A universal spring-probe system for reliable probing of electrochemical lab-on-a-chip devices.

Authors:  Moon-Keun Lee; Tae Jae Lee; Ho Woon Choi; Su Jeong Shin; Jung Youn Park; Seok Jae Lee
Journal:  Sensors (Basel)       Date:  2014-01-08       Impact factor: 3.576

10.  Spatial resolution of single-cell exocytosis by microwell-based individually addressable thin film ultramicroelectrode arrays.

Authors:  Jun Wang; Raphaël Trouillon; Johan Dunevall; Andrew G Ewing
Journal:  Anal Chem       Date:  2014-04-23       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.