Literature DB >> 1952084

Etched carbon-fiber electrodes as amperometric detectors of catecholamine secretion from isolated biological cells.

K T Kawagoe1, J A Jankowski, R M Wightman.   

Abstract

Voltammetric electrodes with micrometer dimensions have been fabricated from carbon fibers etched to a conical shape and insulated with poly(oxyphenylene) following literature procedures. The resultant electrode has a tip radius in the micron range. The response of this electrode is compared to a carbon-fiber electrode prepared by sealing a carbon-fiber electrode in a glass pipet (electrode radius greater than 3.5 microns). While the etched electrodes did not follow electrochemical theory as well as the glass-encased electrode, the etched electrode was found to be suitable for the amperometric measurement of the secretion of catecholamines from isolated bovine adrenal cells. Comparable results are only obtained when the two different electrodes are placed 1 micron from the cell surface. When the etched electrode is placed further away, less secretion is observed, because of diffusion and accompanying dilution.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1952084     DOI: 10.1021/ac00015a017

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  27 in total

1.  Controlling the electrochemically active area of carbon fiber microelectrodes by the electrodeposition and selective removal of an insulating photoresist.

Authors:  Bradley A Lambie; Owe Orwar; Stephen G Weber
Journal:  Anal Chem       Date:  2006-07-15       Impact factor: 6.986

2.  Temperature-dependent differences between readily releasable and reserve pool vesicles in chromaffin cells.

Authors:  Christy L Haynes; Lauren N Siff; R Mark Wightman
Journal:  Biochim Biophys Acta       Date:  2007-03-28

3.  Regional differences in dopamine release in the R6/2 mouse caudate putamen.

Authors:  Sam V Kaplan; Ryan A Limbocker; Beth Levant; Michael A Johnson
Journal:  Electroanalysis       Date:  2018-03-30       Impact factor: 3.223

4.  Regulation of exocytotic fusion by cell inflation.

Authors:  C Solsona; B Innocenti; J M Fernández
Journal:  Biophys J       Date:  1998-02       Impact factor: 4.033

Review 5.  Recent advances in fast-scan cyclic voltammetry.

Authors:  Pumidech Puthongkham; B Jill Venton
Journal:  Analyst       Date:  2020-02-17       Impact factor: 4.616

6.  Low threshold T-type calcium current in rat embryonic chromaffin cells.

Authors:  R Bournaud; J Hidalgo; H Yu; E Jaimovich; T Shimahara
Journal:  J Physiol       Date:  2001-11-15       Impact factor: 5.182

7.  Epoxy insulated carbon fiber and carbon nanotube fiber microelectrodes.

Authors:  Alexander G Zestos; Michael D Nguyen; Brian L Poe; Christopher B Jacobs; B Jill Venton
Journal:  Sens Actuators B Chem       Date:  2013-03-27       Impact factor: 7.460

8.  Colocalization of calcium entry and exocytotic release sites in adrenal chromaffin cells.

Authors:  I M Robinson; J M Finnegan; J R Monck; R M Wightman; J M Fernandez
Journal:  Proc Natl Acad Sci U S A       Date:  1995-03-28       Impact factor: 11.205

9.  Electrochemical nanoprobes for the chemical detection of neurotransmitters.

Authors:  Mei Shen; Michelle L Colombo
Journal:  Anal Methods       Date:  2015-09-07       Impact factor: 2.896

10.  Controlled on-chip stimulation of quantal catecholamine release from chromaffin cells using photolysis of caged Ca2+ on transparent indium-tin-oxide microchip electrodes.

Authors:  Xiaohui Chen; Yuanfang Gao; Maruf Hossain; Shubhra Gangopadhyay; Kevin D Gillis
Journal:  Lab Chip       Date:  2007-10-26       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.