Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15-18 years.

Ole Reigstad1, Per Siewers, Magne Røkkum, Birgitte Espehaug.   

Abstract

BACKGROUND: The long-term results of uncemented total hip arthroplasties vary widely due to differences in design, metal alloy, coating, surface structure, and porosity. PATIENTS AND METHODS: We retrospectively studied 75 cementless Zweymuller SL stems in combination with Endler titanium-backed threaded cups (Z-E) in 70 patients. 35 patients were women, and the mean age at surgery was 52 (24-68) years. 16 patients died and 1 emigrated, 7 patients (of which 1 later died) subsequently underwent revision, and the remaining 47 patients with 50 original arthroplasties were followed up after a median of 16 (15-18) years.
RESULTS: Revision of 8 hips resulted in an 18-year Kaplan-Meier estimated overall survival rate of 88% (CI: 79-96). 6 of 7 cup revisions were due to liner wear and osteolysis, and 1 was due to aseptic loosening. 2 of 3 stem revisions were due to femoral loosening and 1 was due to fracture of the neck of the stem. The clinical results were good, with a mean Harris hip score of 89 (54-100). Half of 70 hips in 65 patients had ectopic bone formation. All unrevised implants were radiographically stable, with a mean liner wear of 0.07 mm/year.
INTERPRETATION: These long-term results demonstrate that the combination of a Zweymuller SL stem and an Endler titanium-backed screw cup is a good hip arthroplasty in young and active patients. A prefixed polyethylene liner is a drawback, necessitating exchange of the whole cup in cases with polyethylene wear.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18484244     DOI: 10.1080/17453670710014978

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  19 in total

1.  Survival of the cementless Spotorno stem in the second decade.

Authors:  Peter R Aldinger; Alexander W Jung; Steffen J Breusch; Volker Ewerbeck; Dominik Parsch
Journal:  Clin Orthop Relat Res       Date:  2009-06-06       Impact factor: 4.176

2.  Thirteen year follow-up of a cementless femoral stem and a threaded acetabular cup in patients younger than fifty years of age.

Authors:  Jan Schmolders; Grigoris Amvrazis; Peter H Pennekamp; Andreas Christian Strauss; Max Julian Friedrich; Matthias D Wimmer; Yorck Rommelspacher; Dieter Christian Wirtz; Thomas Wallny
Journal:  Int Orthop       Date:  2016-05-30       Impact factor: 3.075

3.  Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Göran Garellick; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

4.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

5.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

6.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

7.  Custom cementless stem improves hip function in young patients at 15-year followup.

Authors:  Xavier Flecher; Oliver Pearce; Sebastien Parratte; Jean-Manuel Aubaniac; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

8.  High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.

Authors:  Nikolaos A Christodoulou; Konstantinos P Dialetis; Athanasios N Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-01-05       Impact factor: 4.176

Review 9.  [Uncemented arthroplasty of the hip].

Authors:  C von Schulze Pellengahr; A Fottner; S Utzschneider; M Schmitt-Sody; W Teske; T Lichtinger; S A Esenwein
Journal:  Orthopade       Date:  2009-05       Impact factor: 1.087

10.  The Nordic Arthroplasty Register Association: a unique collaboration between 3 national hip arthroplasty registries with 280,201 THRs.

Authors:  Leif I Havelin; Anne M Fenstad; Roger Salomonsson; Frank Mehnert; Ove Furnes; Søren Overgaard; Alma B Pedersen; Peter Herberts; Johan Kärrholm; Göran Garellick
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.