Literature DB >> 18471625

Repeatability of corneal first-surface wavefront aberrations measured with Pentacam corneal topography.

Hema Shankar1, Deepa Taranath, Chandramalar T Santhirathelagan, Konrad Pesudovs.   

Abstract

PURPOSE: To assess the repeatability of corneal wavefront aberrations derived from Pentacam (Oculus) corneal topography.
SETTING: Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia.
METHODS: Forty-five normal participants and 10 participants with keratoconus were tested. Intraobserver and interobserver repeatability was determined using 4 observers within and between sessions. Topographical maps were exported to external software, and corneal first-surface wavefront aberrations were calculated using a 10th-order Zernike expansion over a 6.0 mm optical zone. Repeatability was determined with Bland-Altman limits of agreement and expressed as the coefficient of repeatability (COR).
RESULTS: Initial data showed high wavefront aberrations in normal participants and poor repeatability. Topographical maps showed extrapolated topography in zones without data acquisition; maps with less than 6.0 mm of complete data were excluded in the final analysis. The mean wavefront aberrations for normal participants remained high, but repeatability improved. The COR relative to the magnitude of wavefront aberrations was high (average 100%) across all modal pairs and orders, although best for total higher-order root mean square. Participants with keratoconus had higher magnitude wavefront aberrations and poorer repeatability but similar COR to average wavefront aberration ratios. Examination of raw elevation data showed poor repeatability.
CONCLUSIONS: Wavefront aberrations calculated from Pentacam corneal topography were large in magnitude, and reliability was poor, largely due to variability in corneal elevation data. Intraobserver and interobserver reliability within and between sessions was comparable. The Pentacam was not reliable in measuring corneal wavefront aberrations.

Entities:  

Mesh:

Year:  2008        PMID: 18471625     DOI: 10.1016/j.jcrs.2007.11.056

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  16 in total

1.  Changes in corneal aberrations after cataract surgery.

Authors:  Yuki Hidaka; Takefumi Yamaguchi; Megumi Saiki; Murat Dogru; Kazuo Tsubota; Kazuno Negishi
Journal:  Jpn J Ophthalmol       Date:  2016-03-02       Impact factor: 2.447

2.  Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes.

Authors:  David P Piñero; Ainhoa Molina-Martín; Vicent J Camps; Dolores de Fez; María Teresa Caballero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-03       Impact factor: 3.117

3.  Data quality and clinical decision-making: do we trust machines blindly?

Authors:  Konrad Pesudovs; Raymond A Applegate
Journal:  Clin Exp Optom       Date:  2009-05       Impact factor: 2.742

4.  Inverse computational analysis of in vivo corneal elastic modulus change after collagen crosslinking for keratoconus.

Authors:  Abhijit Sinha Roy; Karol M Rocha; J Bradley Randleman; R Doyle Stulting; William J Dupps
Journal:  Exp Eye Res       Date:  2013-05-09       Impact factor: 3.467

5.  A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.

Authors:  Jing Zhao; Wen Yang; Jiao Zhao; Yang Shen; Ling Sun; Tian Han; Xiaoying Wang; Peijun Yao; Xingtao Zhou
Journal:  Ann Transl Med       Date:  2021-04

6.  Corneal topography from spectral optical coherence tomography (sOCT).

Authors:  Sergio Ortiz; Damian Siedlecki; Pablo Pérez-Merino; Noelia Chia; Alberto de Castro; Maciej Szkulmowski; Maciej Wojtkowski; Susana Marcos
Journal:  Biomed Opt Express       Date:  2011-11-04       Impact factor: 3.732

7.  Progression of lower and higher-order aberrations: a longitudinal study.

Authors:  Balamurali Vasudevan; Brian Fisher; Barry Case; Phu Lam; Jeff Wayman
Journal:  BMC Ophthalmol       Date:  2015-01-24       Impact factor: 2.209

8.  Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Nicolas Alejandre; E Gambra; I Jimenez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-04-02       Impact factor: 3.732

9.  Responses of the Ocular Anterior Segment and Refraction to 0.5% Tropicamide in Chinese School-Aged Children of Myopia, Emmetropia, and Hyperopia.

Authors:  Ying Yuan; Zhengwei Zhang; Jianfeng Zhu; Xiangui He; Ergang Du; Kelimu Jiang; Wenjing Zheng; Bilian Ke
Journal:  J Ophthalmol       Date:  2015-09-20       Impact factor: 1.909

10.  Biomechanical Measurement of Rabbit Cornea by a Modified Scheimpflug Device.

Authors:  Bo Zhang; Jianjun Gu; Xiaoxiao Zhang; Bin Yang; Zheng Wang; Danying Zheng
Journal:  J Ophthalmol       Date:  2016-07-03       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.