Literature DB >> 18467898

The pulse oximetry plethysmographic curve revisited.

Karim Bendjelid1.   

Abstract

PURPOSE OF REVIEW: To evaluate the recent literature on the utility of the pulse oximetry plethysmographic curve to assess macrocirculation and microcirculation monitoring in intensive care patients. RECENT
FINDINGS: In patients with sinus rhythm who are hypotensive, deeply sedated, mechanically ventilated, critically ill and in the operation room, plethysmographic pulse variation related to mechanical breath is a recent noninvasive indicator of preload dependency.
SUMMARY: A growing number of recent clinical studies demonstrated that plethysmographic dynamic indices are useful methods to assess fluid responsiveness. Any alternating signal processing of the raw data curves, however, may be detrimental for this purpose, as significant clinically relevant information could be lost after perpetual adjustment of filtering. Hence, time will tell if the pulse oximetry plethysmographic curve will succeed other methods as a noninvasive approach to monitor haemodynamics of critically ill patients.

Entities:  

Mesh:

Year:  2008        PMID: 18467898     DOI: 10.1097/MCC.0b013e3282fb2dc9

Source DB:  PubMed          Journal:  Curr Opin Crit Care        ISSN: 1070-5295            Impact factor:   3.687


  16 in total

1.  Pulse-plethysmographic variables in hemodynamic assessment during mannitol infusion.

Authors:  M Radhakrishnan; K Mohanvelu; S Veena; G Sripathy; G S Umamaheswara Rao
Journal:  J Clin Monit Comput       Date:  2012-02-09       Impact factor: 2.502

Review 2.  Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Claudio Sandroni; Fabio Cavallaro; Cristina Marano; Chiara Falcone; Paolo De Santis; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2012-06-26       Impact factor: 17.440

Review 3.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

4.  The pre-ejection period during the Muller manoeuvre: mismatch or misreading?

Authors:  Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2014-06       Impact factor: 2.502

5.  Fingertip photoplethysmographic waveform variability and systemic vascular resistance in intensive care unit patients.

Authors:  Paul M Middleton; Gregory S H Chan; Elizabeth Steel; Philip Malouf; Christopher Critoph; Gordon Flynn; Emma O'Lone; Branko G Celler; Nigel H Lovell
Journal:  Med Biol Eng Comput       Date:  2011-02-22       Impact factor: 2.602

Review 6.  Year in review in journal of clinical monitoring and computing 2014: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Lester Critchley
Journal:  J Clin Monit Comput       Date:  2015-03-05       Impact factor: 2.502

7.  Identification of return of spontaneous circulation during cardiopulmonary resuscitation via pulse oximetry in a porcine animal cardiac arrest model.

Authors:  Chen Li; Jun Xu; Fei Han; Joseph Walline; Liangliang Zheng; Yangyang Fu; Huadong Zhu; Yanfen Chai; Xuezhong Yu
Journal:  J Clin Monit Comput       Date:  2018-11-29       Impact factor: 2.502

8.  Non-invasive monitoring using photoplethysmography technology.

Authors:  Keisuke Tomita; Taka-Aki Nakada; Taku Oshima; Takehiko Oami; Tuerxun Aizimu; Shigeto Oda
Journal:  J Clin Monit Comput       Date:  2018-10-04       Impact factor: 2.502

9.  Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status.

Authors:  Raphaël Giraud; Nils Siegenthaler; Denis R Morel; Jacques-A Romand; Laurent Brochard; Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2012-11-02       Impact factor: 2.502

10.  Hemodynamic monitoring development: helpful technology or expensive luxury?

Authors:  Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2012-10       Impact factor: 2.502

View more