Literature DB >> 18465883

Towards absolute quantification of therapeutic monoclonal antibody in serum by LC-MS/MS using isotope-labeled antibody standard and protein cleavage isotope dilution mass spectrometry.

Olivier Heudi1, Samuel Barteau, Dieter Zimmer, Joerg Schmidt, Kurt Bill, Natalie Lehmann, Christian Bauer, Olivier Kretz.   

Abstract

Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four (13)C atoms and one (15)N atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 microg/mL mAb with accuracy and precision within +/-15% at all concentrations and below +/-20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and Cmax with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18465883     DOI: 10.1021/ac800205s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  26 in total

1.  Nano-scale liquid chromatography/mass spectrometry and on-the-fly orthogonal array optimization for quantification of therapeutic monoclonal antibodies and the application in preclinical analysis.

Authors:  Xiaotao Duan; Lipeng Dai; Shang-Chiung Chen; Joseph P Balthasar; Jun Qu
Journal:  J Chromatogr A       Date:  2012-06-21       Impact factor: 4.759

2.  Establishing ion ratio thresholds based on absolute peak area for absolute protein quantification using protein cleavage isotope dilution mass spectrometry.

Authors:  Philip L Loziuk; Ronald R Sederoff; Vincent L Chiang; David C Muddiman
Journal:  Analyst       Date:  2014-11-07       Impact factor: 4.616

Review 3.  Stable-isotope dilution LC–MS for quantitative biomarker analysis.

Authors:  Eugene Ciccimaro; Ian A Blair
Journal:  Bioanalysis       Date:  2010-02       Impact factor: 2.681

4.  4th European Antibody Congress 2008: December 1-3, 2008, Geneva, Switzerland.

Authors:  Alain Beck; Sherif Hanala; Janice M Reichert
Journal:  MAbs       Date:  2009-03-20       Impact factor: 5.857

Review 5.  Bioanalytical approaches to quantify "total" and "free" therapeutic antibodies and their targets: technical challenges and PK/PD applications over the course of drug development.

Authors:  Jean W Lee; Marian Kelley; Lindsay E King; Jihong Yang; Hossein Salimi-Moosavi; Meina T Tang; Jian-Feng Lu; John Kamerud; Ago Ahene; Heather Myler; Cindy Rogers
Journal:  AAPS J       Date:  2011-01-15       Impact factor: 4.009

6.  5th European Antibody Congress 2009: November 30–December 2, 2009, Geneva, Switzerland.

Authors:  Alain Beck; Janice M Reichert; Thierry Wurch
Journal:  MAbs       Date:  2010 Mar-Apr       Impact factor: 5.857

7.  Comparability analysis of protein therapeutics by bottom-up LC-MS with stable isotope-tagged reference standards.

Authors:  Anton V Manuilov; Czeslaw H Radziejewski; David H Lee
Journal:  MAbs       Date:  2011-07-01       Impact factor: 5.857

8.  Monoclonal antibodies biosimilarity assessment using transient isotachophoresis capillary zone electrophoresis-tandem mass spectrometry.

Authors:  Rabah Gahoual; Michaël Biacchi; Johana Chicher; Lauriane Kuhn; Philippe Hammann; Alain Beck; Emmanuelle Leize-Wagner; Yannis N François
Journal:  MAbs       Date:  2014       Impact factor: 5.857

9.  Recommendations for validation of LC-MS/MS bioanalytical methods for protein biotherapeutics.

Authors:  Rand Jenkins; Jeffrey X Duggan; Anne-Françoise Aubry; Jianing Zeng; Jean W Lee; Laura Cojocaru; Dawn Dufield; Fabio Garofolo; Surinder Kaur; Gary A Schultz; Keyang Xu; Ziping Yang; John Yu; Yan J Zhang; Faye Vazvaei
Journal:  AAPS J       Date:  2014-11-13       Impact factor: 4.009

10.  Development of different analysis platforms with LC-MS for pharmacokinetic studies of protein drugs.

Authors:  Qiaozhen Lu; Xiaoyang Zheng; Thomas McIntosh; Hugh Davis; Jennifer F Nemeth; Chuck Pendley; Shiaw-Lin Wu; William S Hancock
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.