Literature DB >> 18452377

The Angioguard embolic protection device.

Gail M Siewiorek1, Mark K Eskandari, Ender A Finol.   

Abstract

Endovascular management of cardiovascular disease is quickly becoming a more popular treatment. The effectiveness in using embolic protection devices (EPDs), such as the Angioguard XP filter, during carotid artery stenting (CAS) is a topic of ongoing controversy and scrutiny. Early clinical results indicate that EPDs can reduce complications associated with CAS. However, the incidence of stroke and postprocedural embolic events are statistically similar when comparing CAS with the gold standard in carotid stenosis repair, carotid endarterectomy (CEA). The focus of this manuscript is the critical evaluation of Angioguard XP with respect to numerous in vitro and ex vivo experiments, and clinical trials that have been conducted by the authors and other researchers to investigate the efficacy of EPDs with the objective of suggesting engineering design considerations for future generations of these devices. Angioguard XP has had mixed performance outcomes in in vitro testing reported in the literature. In our laboratory, this device had undesirable measures of performance in bench-top testing protocols using in vitro flow models. Technical considerations relevant to design of EPDs, such as ideal pore size, effective wall apposition in tortuous geometry and maximization of capture efficiency have not been addressed adequately in the literature. It is likely that in the future both CAS and CEA will coexist as potential forms of treatment in the clinical management of cerebrovascular disease.

Entities:  

Mesh:

Year:  2008        PMID: 18452377      PMCID: PMC3064459          DOI: 10.1586/17434440.5.3.287

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  40 in total

1.  In vitro comparison of four cerebral protection filters for preventing human plaque embolization during carotid interventions.

Authors:  Stefan Müller-Hülsbeck; Thomas Jahnke; Carsten Liess; Christoph Glass; Friedrich Paulsen; Jan Grimm; Martin Heller
Journal:  J Endovasc Ther       Date:  2002-12       Impact factor: 3.487

2.  Comparison of 4 cerebral protection filters for carotid angioplasty: an in vitro experiment focusing on carotid anatomy.

Authors:  Berndt-M Order; Christoph Glass; Carsten Liess; Martin Heller; Stefan Müller-Hülsbeck
Journal:  J Endovasc Ther       Date:  2004-04       Impact factor: 3.487

3.  Atheroemboli to the brain: size threshold for causing acute neuronal cell death.

Authors:  J H Rapp; X M Pan; F R Sharp; D M Shah; G A Wille; P M Velez; A Troyer; R T Higashida; D Saloner
Journal:  J Vasc Surg       Date:  2000-07       Impact factor: 4.268

4.  Heart disease and stroke statistics--2006 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee.

Authors:  Thomas Thom; Nancy Haase; Wayne Rosamond; Virginia J Howard; John Rumsfeld; Teri Manolio; Zhi-Jie Zheng; Katherine Flegal; Christopher O'Donnell; Steven Kittner; Donald Lloyd-Jones; David C Goff; Yuling Hong; Robert Adams; Gary Friday; Karen Furie; Philip Gorelick; Brett Kissela; John Marler; James Meigs; Veronique Roger; Stephen Sidney; Paul Sorlie; Julia Steinberger; Sylvia Wasserthiel-Smoller; Matthew Wilson; Philip Wolf
Journal:  Circulation       Date:  2006-01-11       Impact factor: 29.690

5.  Updated review of the global carotid artery stent registry.

Authors:  Michael H Wholey; Nadim Al-Mubarek; Mark H Wholey
Journal:  Catheter Cardiovasc Interv       Date:  2003-10       Impact factor: 2.692

6.  Cerebral ischemia and infarction from atheroemboli <100 microm in Size.

Authors:  Joseph H Rapp; Xian Mang Pan; Bo Yu; Raymond A Swanson; Randall T Higashida; Paul Simpson; David Saloner
Journal:  Stroke       Date:  2003-07-10       Impact factor: 7.914

Review 7.  Filter devices for cerebral protection during carotid angioplasty and stenting.

Authors:  Karthikeshwar Kasirajan; Peter A Schneider; K Craig Kent
Journal:  J Endovasc Ther       Date:  2003-12       Impact factor: 3.487

8.  Protected carotid-artery stenting versus endarterectomy in high-risk patients.

Authors:  Jay S Yadav; Mark H Wholey; Richard E Kuntz; Pierre Fayad; Barry T Katzen; Gregory J Mishkel; Tanvir K Bajwa; Patrick Whitlow; Neil E Strickman; Michael R Jaff; Jeffrey J Popma; David B Snead; Donald E Cutlip; Brian G Firth; Kenneth Ouriel
Journal:  N Engl J Med       Date:  2004-10-07       Impact factor: 91.245

9.  Comparison of various cerebral protection devices used for carotid artery stent placement: an in vitro experiment.

Authors:  Stefan Müller-Hülsbeck; Thomas Jahnke; Carsten Liess; Christoph Glass; Jan Grimm; Martin Heller
Journal:  J Vasc Interv Radiol       Date:  2003-05       Impact factor: 3.464

10.  Is carotid angioplasty and stenting more cost effective than carotid endarterectomy?

Authors:  Sashi Kilaru; Peter Korn; Karthikeshwar Kasirajan; Thomas Y Lee; Frederick P Beavers; Ross T Lyon; Harry L Bush; K Craig Kent
Journal:  J Vasc Surg       Date:  2003-02       Impact factor: 4.268

View more
  5 in total

1.  Computational modeling of distal protection filters.

Authors:  Gail M Siewiorek; Ender A Finol
Journal:  J Endovasc Ther       Date:  2010-12       Impact factor: 3.487

2.  Initial experience of carotid artery stenting using the Carotid WALLSTENT and FilterWire EZ in Japan.

Authors:  Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Toshiteru Miyasaka; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Ryota Kimura; Shinichiro Kurokawa; Kimihiko Kichikawa
Journal:  Jpn J Radiol       Date:  2011-01-26       Impact factor: 2.374

3.  The association of clinical variables and filter design with carotid artery stenting thirty-day outcome.

Authors:  G M Siewiorek; R T Krafty; M H Wholey; E A Finol
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-04-29       Impact factor: 7.069

4.  Magnetic resonance plaque imaging to predict the occurrence of the slow-flow phenomenon in carotid artery stenting procedures.

Authors:  Masahiko Sakamoto; Toshiaki Taoka; Hiroyuki Nakagawa; Katsutoshi Takayama; Takeshi Wada; Kaoru Myouchin; Toshiaki Akashi; Toshiteru Miyasaka; Akio Fukusumi; Satoru Iwasaki; Kimihiko Kichikawa
Journal:  Neuroradiology       Date:  2010-04       Impact factor: 2.804

5.  Combined Transradial and Transfemoral Approach With Ostial Vertebral Balloon Protection for the Treatment of Patients With Subclavian Steal Syndrome.

Authors:  Rami Fakih; Sudeepta Dandapat; Alan Mendez-Ruiz; Aldo A Mendez; Mudassir Farooqui; Cynthia Zevallos; Darko Quispe Orozco; David Hasan; James Rossen; Edgar A Samaniego; Colin Derdeyn; Santiago Ortega-Gutierrez
Journal:  Front Neurol       Date:  2020-10-22       Impact factor: 4.003

  5 in total