Literature DB >> 18450841

Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality.

J Mascherbauer1, R Rosenhek, C Fuchs, E Pernicka, U Klaar, C Scholten, M Heger, G Wollenek, G Maurer, H Baumgartner.   

Abstract

BACKGROUND: The importance of moderate patient-prosthesis mismatch (PPM) for the prognosis of patients who undergo aortic valve replacement is unclear.
METHODS: The presence of PPM was assessed in 361 consecutive patients undergoing valve replacement for isolated severe aortic stenosis and related to perioperative and postoperative mortality. Indexed effective orifice areas (EOAi) were estimated for each type and size of prosthesis.
RESULTS: Using the previously proposed cut-off of EOAi <or=0.8 cm(2)/m(2), PPM was present in 54% of patients. Patients were followed for 4.1 (2.0) years. Survival tended to be slightly, but insignificantly, worse in the group with PPM (1-year, 3-year and 5-year survival 89%, 86% and 76% vs 92%, 88% and 82%; p = 0.21). However, patients with PPM were also older (p<0.0001), more often female (p<0.0001), more symptomatic (p = 0.001), more often had coronary artery disease (p = 0.04), triple vessel disease (p = 0.03) and hypertension (p = 0.01) and presented with a higher EuroSCORE (p<0.0001). By multivariate analysis only EuroSCORE and diabetes but not PPM were independent predictors of survival.
CONCLUSIONS: Moderate PPM is a frequent finding after aortic valve replacement. In our patient population it had no impact on short-term and long-term survival. It may therefore not be justified to recommend complex surgical interventions to avoid moderate PPM in patients undergoing aortic valve replacement for isolated severe aortic stenosis.

Entities:  

Mesh:

Year:  2008        PMID: 18450841     DOI: 10.1136/hrt.2008.142596

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  10 in total

1.  Impact of New York Heart Association classification, advanced age and patient-prosthesis mismatch on outcomes in aortic valve replacement surgery.

Authors:  Alex Zapolanski; Andrew W C Mak; Giovanni Ferrari; Christopher Johnson; Richard E Shaw; Mariano E Brizzio; Jason S Sperling; Juan B Grau
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-04

Review 2.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

3.  Small prosthesis size in aortic valve replacement does not affect mortality.

Authors:  Damien J LaPar; Gorav Ailawadi; Castigliano M Bhamidipati; George Stukenborg; Ivan K Crosby; John A Kern; Irving L Kron
Journal:  Ann Thorac Surg       Date:  2011-09       Impact factor: 4.330

Review 4.  Natriuretic peptides in the management of aortic stenosis.

Authors:  Jutta Bergler-Klein
Journal:  Curr Cardiol Rep       Date:  2009-03       Impact factor: 2.931

Review 5.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

6.  Factors determining patient-prosthesis mismatch after aortic valve replacement--a prospective cohort study.

Authors:  Diana Bonderman; Alexandra Graf; Andreas A Kammerlander; Alfred Kocher; Guenter Laufer; Irene M Lang; Julia Mascherbauer
Journal:  PLoS One       Date:  2013-12-03       Impact factor: 3.240

7.  Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement.

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  J Cardiothorac Surg       Date:  2013-04-17       Impact factor: 1.637

8.  Can postoperative mean transprosthetic pressure gradient predict survival after aortic valve replacement?

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  Clin Res Cardiol       Date:  2013-10-18       Impact factor: 5.460

9.  Determinants of clinical improvement after surgical replacement or transcatheter aortic valve implantation for isolated aortic stenosis.

Authors:  Cristina Gavina; Alexandra Gonçalves; Carlos Almeria; Rosana Hernandez; Adelino Leite-Moreira; Francisco Rocha-Gonçalves; José Zamorano
Journal:  Cardiovasc Ultrasound       Date:  2014-10-06       Impact factor: 2.062

10.  Early outcomes of patient-prosthesis mismatch following aortic valve replacement.

Authors:  Serik Aitaliyev; Egle Rumbinaitė; Karolina Mėlinytė-Ankudavičė; Rokas Nekrošius; Vytenis Keturakis; Rimantas Benetis
Journal:  Perfusion       Date:  2021-06-03       Impact factor: 1.581

  10 in total