Literature DB >> 18440346

How accurately, reproducibly, and efficiently can we measure left ventricular indices using M-mode, 2-dimensional, and 3-dimensional echocardiography in children?

Xiuzhang Lu1, Mingxing Xie, David Tomberlin, Berthold Klas, Vyacheslav Nadvoretskiy, Nancy Ayres, Jeffrey Towbin, Shuping Ge.   

Abstract

BACKGROUND: Measurements of left ventricular (LV) size, mass, and function are the most common and important tasks for echocardiography in clinical practice and research in children with congenital and acquired heart diseases. There are little data to compare the utility of M-mode (MM), 2-dimensional (2D), and 3-dimensional (3D) echocardiographic techniques for quantification of LV indices. The objective of the study was to assess the accuracy, reproducibility, and efficiency of these echocardiographic methods for measurement of LV indices in children.
METHODS: A prospective study was conducted in 20 consecutive children (mean 10.6 +/- 2.8 years, 11 male and 9 female subjects) using conventional MM, 2D, and real-time 3D echocardiography (RT3DE). A Sonos 7500 system (Philips Medical Systems, Andover, MA) was used. M-mode and 2DE measurements were made according to the American Society of echocardiography recommendations. To include the entire LV for volumetric measurement, full-volume 3D data sets were acquired from 4 electrocardiogram gated subvolumes. The 3DE measurements were made off-line manually using 4-plane and 8-plane algorithms by 4D Echo-View (TomTec Imaging Systems, Munich, Germany) and a semiautomated algorithm by QLAB (Philips Medical Systems). Magnetic resonance imaging studies were also performed to determine the LV indices by a disk summation method based on the Simpson principle.
RESULTS: The correlation and agreement between MM, 2D, and RT3D echocardiography and magnetic resonance imaging measurements are good (r = 0.81-0.97) for the 3 methods. The correlation was superior for RT3DE compared with 2DE and MM. The correlation and agreement were similar for the three 3DE methods. The intra- and interobserver variabilities ranged from MM (4.3%-4.8% and 7.0%-8.7%), 2DE (3.3%-4.5% and 5.5%-7.3%), and 3DE (0.4%-2.3%, and 0.2%-4.8%). The total time (acquisition and analysis) used for MM measurements was the least compared with 2DE and 3DE. The total time for 3DE using the semiautomated algorithms was not significantly different compared with that for 2DE.
CONCLUSIONS: Our study showed that MM provides the most efficient assessment of LV indices but is the least accurate and reproducible technique compared with 2DE and 3DE. Three-dimensional echocardiography using both automated and manual analysis algorithm is superior to MM and 2DE for measurements of LV indices, and the automated 3DE algorithm is as efficient as 2DE. Therefore, 3DE using the automated algorithm is the method of choice for quantification of LV indices.

Entities:  

Mesh:

Year:  2008        PMID: 18440346     DOI: 10.1016/j.ahj.2007.11.034

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  16 in total

1.  Left ventricular mass and systolic function in children with chronic kidney disease-comparing echocardiography with cardiac magnetic resonance imaging.

Authors:  Raoul Arnold; Daniel Schwendinger; Sabine Jung; Martin Pohl; Bernd Jung; Julia Geiger; Charlotte Gimpel
Journal:  Pediatr Nephrol       Date:  2015-09-05       Impact factor: 3.714

2.  Interpreting measurements of cardiac function using vendor-independent speckle tracking echocardiography in children: a prospective, blinded comparison with catheter-derived measurements.

Authors:  Suma P Goudar; G Hamilton Baker; Shahryar M Chowdhury; Kimberly J Reid; Girish Shirali; Mark A Scheurer
Journal:  Echocardiography       Date:  2016-10-14       Impact factor: 1.724

Review 3.  [Current value of 3D echocardiography in international guidelines].

Authors:  B Plicht; T Buck
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

4.  Left Ventricular Dilation: When Pediatric Meet Adult Guidelines.

Authors:  Jill Harmon; Kacy Sisco; Marc Dutro; Clifford L Cua
Journal:  Pediatr Cardiol       Date:  2017-09-07       Impact factor: 1.655

Review 5.  Imaging of patients with congenital heart disease.

Authors:  Arno A W Roest; Albert de Roos
Journal:  Nat Rev Cardiol       Date:  2011-11-01       Impact factor: 32.419

6.  Speckle tracking echocardiography detects decreased cardiac longitudinal function in anthracycline-exposed survivors of childhood cancer.

Authors:  Kaisa Ylänen; Anneli Eerola; Kim Vettenranta; Tuija Poutanen
Journal:  Eur J Pediatr       Date:  2016-09-13       Impact factor: 3.183

7.  Transcatether closure of an atrial redirection baffle leak.

Authors:  Brian D Soriano; Karen K Stout; Colleen D Cailes; Thomas K Jones
Journal:  Ann Pediatr Cardiol       Date:  2009-01

Review 8.  Current cardiac imaging techniques for detection of left ventricular mass.

Authors:  Aksuyek S Celebi; Hulya Yalcin; Fatih Yalcin
Journal:  Cardiovasc Ultrasound       Date:  2010-06-01       Impact factor: 2.062

9.  Three-dimensional echocardiographic virtual endoscopy for the diagnosis of congenital heart disease in children.

Authors:  Haihong Xue; Kun Sun; Jianguo Yu; Binjin Chen; Guozhen Chen; Wenjing Hong; Liping Yao; Lanping Wu
Journal:  Int J Cardiovasc Imaging       Date:  2010-06-10       Impact factor: 2.357

10.  Ventricular pressure-volume loops obtained by 3D real-time echocardiography and mini pressure wire-a feasibility study.

Authors:  Ulrike Herberg; Eva Gatzweiler; Thomas Breuer; Johannes Breuer
Journal:  Clin Res Cardiol       Date:  2013-02-09       Impact factor: 5.460

View more