Literature DB >> 18437533

Structure, mechanical properties, and grindability of dental Ti-Zr alloys.

Wen-Fu Ho1, Wei-Kai Chen, Shih-Ching Wu, Hsueh-Chuan Hsu.   

Abstract

Structure, mechanical properties and grindability of a series of binary Ti-Zr alloys with zirconium contents ranging from 10 to 40 wt% have been investigated. Commercially pure titanium (c.p. Ti) was used as a control. Experimental results indicated that the diffraction peaks of all the Ti-Zr alloys matched those for alpha Ti. No beta-phase peaks were found. The hardness of the Ti-Zr alloys increased as the Zr contents increased, and ranged from 266 HV (Ti-10Zr) to 350 HV (Ti-40Zr). As the concentration of zirconium in the alloys increased, the strength, elastic recovery angles and hardness increased. Moreover, the elastically recoverable angle of Ti-40Zr was higher than of c.p. Ti by as much as 550%. The grindability of each metal was found to be largely dependent on the grinding conditions. The Ti-40Zr alloy had a higher grinding rate and grinding ratio than c.p. Ti at low speed. The grinding rate of the Ti-40Zr alloy at 500 m/min was about 1.8 times larger than that of c.p. Ti, and the grinding ratio was about 1.6 times larger than that of c.p. Ti. Our research suggested that the Ti-40Zr alloy has better mechanical properties, excellent elastic recovery capability and improved grindability at low grinding speed. The Ti-40Zr alloy has a great potential for use as a dental machining alloy.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18437533     DOI: 10.1007/s10856-008-3454-x

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  23 in total

1.  Thermal expansion and microstructural analysis of experimental metal-ceramic titanium alloys.

Authors:  Spiros Zinelis; Athena Tsetsekou; Triantafillos Papadopoulos
Journal:  J Prosthet Dent       Date:  2003-10       Impact factor: 3.426

2.  Structure, castability and mechanical properties of commercially pure and alloyed titanium cast in graphite mould.

Authors:  W W Cheng; C P Ju; J H Chern Lin
Journal:  J Oral Rehabil       Date:  2007-07       Impact factor: 3.837

3.  Wear characteristics of burs.

Authors:  M H Reisbick; R F Bunshah
Journal:  J Dent Res       Date:  1973 Sep-Oct       Impact factor: 6.116

4.  Cutting times and grinding rates of various crown and bridge metals.

Authors:  R Grajower; I Kurz; M S Bapna
Journal:  Dent Mater       Date:  1986-10       Impact factor: 5.304

5.  Cutting efficiency of air-turbine burs on cast titanium and dental casting alloys.

Authors:  I Watanabe; C Ohkubo; J P Ford; M Atsuta; T Okabe
Journal:  Dent Mater       Date:  2000-11       Impact factor: 5.304

6.  Casting accuracy of experimental Ti-Cu alloys.

Authors:  M Hattori; K Hasegawa; M Yoshinari; E Kawada; Y Oda; T Okabe
Journal:  Dent Mater J       Date:  2001-03       Impact factor: 2.102

Review 7.  Titanium and titanium alloys as dental materials.

Authors:  E P Lautenschlager; P Monaghan
Journal:  Int Dent J       Date:  1993-06       Impact factor: 2.512

8.  Grindability of dental cast Ti-Ag and Ti-Cu alloys.

Authors:  Masafumi Kikuchi; Masatoshi Takahashi; Toru Okabe; Osamu Okuno
Journal:  Dent Mater J       Date:  2003-06       Impact factor: 2.102

9.  Mechanical properties and grindability of experimental Ti-Au alloys.

Authors:  Masatoshi Takahashi; Masafumi Kikuchi; Osamu Okuno
Journal:  Dent Mater J       Date:  2004-06       Impact factor: 2.102

10.  Effects of aluminum and other cations on the structure of brain and liver chromatin.

Authors:  P R Walker; J LeBlanc; M Sikorska
Journal:  Biochemistry       Date:  1989-05-02       Impact factor: 3.162

View more
  17 in total

1.  Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

Authors:  Kıvanç Akça; Atılım Eser; Yeliz Çavuşoğlu; Elçin Sağırkaya; Murat Cavit Çehreli
Journal:  Med Biol Eng Comput       Date:  2015-03-01       Impact factor: 2.602

2.  Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.

Authors:  F Rosalbino; S Delsante; G Borzone; G Scavino
Journal:  J Mater Sci Mater Med       Date:  2012-03-02       Impact factor: 3.896

3.  Assessment of the stresses produced on the bone implant/tissue interface to the different insertion angulations of the implant - a three-dimensional analysis by the finite elements method.

Authors:  Joelson-Rodrigues Brum; Fabiano-Rito Macedo; Millena-Barroso Oliveira; Luiz-Renato Paranhos; Rui-Barbosa Brito-Júnior; Juliana-Cama Ramacciato
Journal:  J Clin Exp Dent       Date:  2020-10-01

4.  Implant insertion angle and depth: Peri-implant bone stress analysis by the finite element method.

Authors:  Fabiano Rito-Macedo; Millena Barroso-Oliveira; Luiz-Renato Paranhos; Joelson Rodrigues-Brum; Igor-Felipe Pereira-Lima; Fabiana-Mantovani Gomes-França; Rui-Barbosa de Brito-Junior
Journal:  J Clin Exp Dent       Date:  2021-12-01

5.  Electrolytic deposition of hydroxyapatite coating on thermal treated Ti-40Zr.

Authors:  Hsueh-Chuan Hsu; Shih-Ching Wu; Chih-Hung Lin; Wen-Fu Ho
Journal:  J Mater Sci Mater Med       Date:  2009-04-29       Impact factor: 3.896

6.  Preparation, structural, microstructural, mechanical and cytotoxic characterization of as-cast Ti-25Ta-Zr alloys.

Authors:  Pedro Akira Bazaglia Kuroda; Fernanda de Freitas Quadros; Karolyne Dos Santos Jorge Sousa; Tatiani Ayako Goto Donato; Raul Oliveira de Araújo; Carlos Roberto Grandini
Journal:  J Mater Sci Mater Med       Date:  2020-01-21       Impact factor: 3.896

7.  Screening on binary Ti alloy with excellent mechanical property and castability for dental prosthesis application.

Authors:  H F Li; K J Qiu; W Yuan; F Y Zhou; B L Wang; L Li; Y F Zheng; Y H Liu
Journal:  Sci Rep       Date:  2016-11-22       Impact factor: 4.379

8.  Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants.

Authors:  Aritza Brizuela-Velasco; Esteban Pérez-Pevida; Antonio Jiménez-Garrudo; Francisco Javier Gil-Mur; José María Manero; Miquel Punset-Fuste; David Chávarri-Prado; Markel Diéguez-Pereira; Francesca Monticelli
Journal:  Biomed Res Int       Date:  2017-11-29       Impact factor: 3.411

9.  The Influence of Small Quantities of Oxygen in the Structure, Microstructure, Hardness, Elasticity Modulus and Cytocompatibility of Ti-Zr Alloys for Dental Applications.

Authors:  Fábio B Vicente; Diego R N Correa; Tatiani A G Donato; Victor E Arana-Chavez; Marília A R Buzalaf; Carlos R Grandini
Journal:  Materials (Basel)       Date:  2014-01-20       Impact factor: 3.623

10.  High hardness in the biocompatible intermetallic compound β-Ti3Au.

Authors:  Eteri Svanidze; Tiglet Besara; M Fevsi Ozaydin; Chandra Sekhar Tiwary; Jiakui K Wang; Sruthi Radhakrishnan; Sendurai Mani; Yan Xin; Ke Han; Hong Liang; Theo Siegrist; Pulickel M Ajayan; E Morosan
Journal:  Sci Adv       Date:  2016-07-20       Impact factor: 14.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.