Literature DB >> 25725630

Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

Kıvanç Akça1, Atılım Eser, Yeliz Çavuşoğlu, Elçin Sağırkaya, Murat Cavit Çehreli.   

Abstract

The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25725630     DOI: 10.1007/s11517-015-1256-0

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  35 in total

1.  A model of vertebral trabecular bone architecture and its mechanical properties.

Authors:  K S Jensen; L Mosekilde; L Mosekilde
Journal:  Bone       Date:  1990       Impact factor: 4.398

2.  A time-dependent healing function for immediate loaded implants.

Authors:  W Winter; S M Heckmann; H P Weber
Journal:  J Biomech       Date:  2004-12       Impact factor: 2.712

3.  Predicting bone remodeling around tissue- and bone-level dental implants used in reduced bone width.

Authors:  Atilim Eser; Ergin Tonuk; Kivanc Akca; Michel M Dard; Murat Cavit Cehreli
Journal:  J Biomech       Date:  2013-07-19       Impact factor: 2.712

Review 4.  Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature.

Authors:  S Szmukler-Moncler; H Salama; Y Reingewirtz; J H Dubruille
Journal:  J Biomed Mater Res       Date:  1998

5.  The biomaterial-tissue interface: a morphological study utilizing conventional and alternative ultrastructural modalities.

Authors:  D E Steflik; R V McKinney; D L Koth; B B Singh
Journal:  Scan Electron Microsc       Date:  1984

6.  Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid(®)) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients.

Authors:  M Chiapasco; P Casentini; M Zaniboni; E Corsi; T Anello
Journal:  Clin Oral Implants Res       Date:  2011-08-18       Impact factor: 5.977

7.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

8.  Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation.

Authors:  J Y Rho; T Y Tsui; G M Pharr
Journal:  Biomaterials       Date:  1997-10       Impact factor: 12.479

9.  Humeral hypertrophy in response to exercise.

Authors:  H H Jones; J D Priest; W C Hayes; C C Tichenor; D A Nagel
Journal:  J Bone Joint Surg Am       Date:  1977-03       Impact factor: 5.284

10.  Modelling the early phases of bone regeneration around an endosseous oral implant.

Authors:  N Amor; L Geris; J Vander Sloten; H Van Oosterwyck
Journal:  Comput Methods Biomech Biomed Engin       Date:  2009-08       Impact factor: 1.763

View more
  2 in total

1.  Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading.

Authors:  Mateus Bertolini Fernandes Dos Santos; Bruno Massucato Zen; Atais Bacchi
Journal:  Med Biol Eng Comput       Date:  2015-12-11       Impact factor: 2.602

2.  Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials.

Authors:  Haruka Araki; Tamaki Nakano; Shinji Ono; Hirofumi Yatani
Journal:  Int J Implant Dent       Date:  2020-01-29
  2 in total