Literature DB >> 17559621

Structure, castability and mechanical properties of commercially pure and alloyed titanium cast in graphite mould.

W W Cheng1, C P Ju, J H Chern Lin.   

Abstract

This report is a study of structure, castability, mechanical properties as well as corrosion behaviour of titanium doped with up to 5 weight percentage (wt%) of a series of alloy elements, including Ta, Mo, Nb, Hf, Zr, Sn, Bi and Ag. The results indicate that, with addition of 1 wt% alloy element, Bi and Mo were most effective in enhancing the castability of titanium. With more alloy elements added, the castability values of most alloys more or less decreased. Except Ti-Mo system, all Ti alloys with a fine acicular morphology had the same crystal structure (hcp) as that of c.p. Ti with a typical lath type morphology. When 3 wt% or more Mo was added, a finer orthorhombic alpha'' phase was formed. The microhardness and bending strength values of Ti alloys were all higher than those of c.p. Ti. Among all alloys, Ti-Mo system exhibited the highest hardness and strength level. For a certain alloy, the bending strength did not necessarily increase with its alloy content. Except Ti-5Zr and Ti-Mo alloys, the bending moduli of most alloy systems were not much different from that of c.p. Ti. All alloys showed an excellent resistance to corrosion in Hanks' solution at 37 degrees C.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17559621     DOI: 10.1111/j.1365-2842.2003.01151.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  4 in total

1.  Structure, mechanical properties, and grindability of dental Ti-Zr alloys.

Authors:  Wen-Fu Ho; Wei-Kai Chen; Shih-Ching Wu; Hsueh-Chuan Hsu
Journal:  J Mater Sci Mater Med       Date:  2008-04-25       Impact factor: 3.896

2.  Stress Distribution on Various Implant-Retained Bar Overdentures.

Authors:  Övül Kümbüloğlu; Beril Koyuncu; Gözde Yerlioğlu; Nadin Al-Haj Husain; Mutlu Özcan
Journal:  Materials (Basel)       Date:  2022-04-30       Impact factor: 3.748

3.  Potential use of porous titanium-niobium alloy in orthopedic implants: preparation and experimental study of its biocompatibility in vitro.

Authors:  Jian Xu; Xiao-Jun Weng; Xu Wang; Jia-Zhang Huang; Chao Zhang; Hassan Muhammad; Xin Ma; Qian-De Liao
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

4.  Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

Authors:  Izabela C M Moris; Silas Borges Monteiro; Raíssa Martins; Ricardo Faria Ribeiro; Erica A Gomes
Journal:  Biomed Res Int       Date:  2018-01-23       Impact factor: 3.411

  4 in total