Literature DB >> 18429022

Simultaneous acquisition of MR angiography and venography (MRAV).

Yiping P Du1, Zhaoyang Jin.   

Abstract

A dual-echo pulse sequence for simultaneous acquisition of MR angiography and venography (MRAV) is developed. Data acquisition of the second echo for susceptibility-weighted imaging-based MR venography is added to the conventional three-dimensional (3D) time-of-flight (TOF) MRA pulse sequence. Using this dual-echo acquisition approach, the venography data can be acquired without increasing the repetition time, and, therefore, the scan duration of routine TOF MRA scans is maintained. The feasibility of simultaneous acquisition of MRAV is presented in brain scans at different spatial resolutions. The effect of spatial resolution on vein-to-background contrast is also demonstrated. Venous contrast is improved in high-resolution (0.52 x 0.52 x 1.6 mm(3)) images compared to that in standard-resolution (0.78 x 0.78 x 1.6 mm(3)) images. This MRAV technique enables the acquisition of MR venography without the need of an extra scan or injection of contrast agent in routine clinical brain exams at 3T. (c) 2008 Wiley-Liss, Inc.

Mesh:

Year:  2008        PMID: 18429022     DOI: 10.1002/mrm.21581

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Postcontrast susceptibility-weighted imaging: a novel technique for the detection of arteriovenous shunting in vascular malformations of the brain.

Authors:  Bharathi D Jagadeesan; Josser E Delgado Almandoz; Tammie L S Benzinger; Christopher J Moran
Journal:  Stroke       Date:  2011-09-22       Impact factor: 7.914

2.  Enhanced susceptibility-weighted angiography (ESWAN) of cerebral arteries and veins at 1.5 Tesla.

Authors:  L Chen; J Zhang; Q-X Wang; L Peng; X Luo; W-Z Zhu; A K Roshan; J-P Qi; H Wang
Journal:  Br J Radiol       Date:  2014-05-02       Impact factor: 3.039

3.  Dual-echo arteriovenography imaging with 7T MRI.

Authors:  Kyongtae Ty Bae; Sung-Hong Park; Chan-Hong Moon; Jung-Hwan Kim; Diana Kaya; Tiejun Zhao
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

4.  Accuracy of susceptibility-weighted imaging for the detection of arteriovenous shunting in vascular malformations of the brain.

Authors:  Bharathi D Jagadeesan; Josser E Delgado Almandoz; Christopher J Moran; Tammie L S Benzinger
Journal:  Stroke       Date:  2010-11-18       Impact factor: 7.914

5.  Cerebral microbleeds on MR imaging: comparison between 1.5 and 7T.

Authors:  M M A Conijn; M I Geerlings; G-J Biessels; T Takahara; T D Witkamp; J J M Zwanenburg; P R Luijten; J Hendrikse
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-05       Impact factor: 3.825

6.  Simultaneous imaging of radiation-induced cerebral microbleeds, arteries and veins, using a multiple gradient echo sequence at 7 Tesla.

Authors:  Wei Bian; Suchandrima Banerjee; Douglas A C Kelly; Christopher P Hess; Peder E Z Larson; Susan M Chang; Sarah J Nelson; Janine M Lupo
Journal:  J Magn Reson Imaging       Date:  2014-12-04       Impact factor: 4.813

Review 7.  Susceptibility-weighted imaging: current status and future directions.

Authors:  Saifeng Liu; Sagar Buch; Yongsheng Chen; Hyun-Seok Choi; Yongming Dai; Charbel Habib; Jiani Hu; Joon-Yong Jung; Yu Luo; David Utriainen; Meiyun Wang; Dongmei Wu; Shuang Xia; E Mark Haacke
Journal:  NMR Biomed       Date:  2016-05-18       Impact factor: 4.044

8.  Imaging the vessel wall in major peripheral arteries using susceptibility-weighted imaging.

Authors:  Qi Yang; Jiantao Liu; Samuel R S Barnes; Zhen Wu; Kuncheng Li; Jaladhar Neelavalli; Jiani Hu; E Mark Haacke
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

Review 9.  Susceptibility-weighted imaging: technical aspects and clinical applications, part 1.

Authors:  E M Haacke; S Mittal; Z Wu; J Neelavalli; Y-C N Cheng
Journal:  AJNR Am J Neuroradiol       Date:  2008-11-27       Impact factor: 3.825

Review 10.  Susceptibility-weighted imaging: clinical angiographic applications.

Authors:  Samuel R S Barnes; E Mark Haacke
Journal:  Magn Reson Imaging Clin N Am       Date:  2009-02       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.