Quantitative relationship between coronary vasodilator reserve assessed by 82Rb PET imaging and coronary artery stenosis severity.

Constantinos Anagnostopoulos1, Alexandra Almonacid, Georges El Fakhri, Zelmira Curillova, Arkadiusz Sitek, Michael Roughton, Sharmila Dorbala, Jeffrey J Popma, Marcelo F Di Carli.   

Abstract

PURPOSE: The relationship between myocardial blood flow (MBF) and stenosis severity has been determined previously using cyclotron-produced radiotracers such as (15)O-H(2)O and (13)N-ammonia. An attractive alternative to overcome the limitations related to the use of cyclotron might be to use the generator-produced (82)Rb as a flow tracer. The current study was undertaken to investigate the relationship between MBF and coronary vasodilator reserve (CVR) as measured by (82)Rb positron emission tomography (PET) and the percent diameter stenosis as defined by quantitative coronary arteriography.
METHODS: We prospectively evaluated 22 individuals: 15 patients (60 +/- 11 years of age) with angiographically documented coronary artery disease (CAD) and seven age-matched (56 +/- 9 years) asymptomatic individuals without risk factors for CAD. Dynamic (82)Rb PET was performed at rest and after dipyridamole vasodilation. MBF, CVR and an index of 'minimal coronary resistance' (MCR) were assessed in each of the three main coronary territories.
RESULTS: Rest and stress MBF in regions subtended by vessels with less than 50% diameter stenosis was similar to that of the individuals with no risk factors for CAD. As a result, CVR was also similar in the two groups (1.9, interquartile [IQ] range from 1.7 to 2.7 vs. 2.2, IQ range from 2 to 3.4 respectively, p = 0.09). CVR successfully differentiated coronary lesions with stenosis severity 70% to 89% from those with 50% to 69% stenosis (1, IQ range from 1 to 1.3 vs. 1.7, IQ range from 1.4 to 2), respectively, p = 0.001. In addition, hyperaemic MBF (r (2) = 0.74, p < 0.001), CVR (r (2) = 0.69, p < 0.001) and MCR (r (2) = 0.78, p < 0.001) measurements were inversely and non-linearly correlated to the percent diameter stenosis on angiography.
CONCLUSION: MBF and CVR are inversely and non-linearly correlated to stenosis severity. Quantitative (82)Rb PET can be a clinically useful tool for an accurate functional assessment of CAD.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18425513      PMCID: PMC3124702          DOI: 10.1007/s00259-008-0793-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  23 in total

1.  Quantification of myocardial perfusion in human subjects using 82Rb and wavelet-based noise reduction.

Authors:  J W Lin; R R Sciacca; R L Chou; A F Laine; S R Bergmann
Journal:  J Nucl Med       Date:  2001-02       Impact factor: 10.057

2.  CONTROL OF CORONARY BLOOD FLOW BY AN AUTOREGULATORY MECHANISM.

Authors:  P MOSHER; J ROSS; P A MCFATE; R F SHAW
Journal:  Circ Res       Date:  1964-03       Impact factor: 17.367

3.  Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses.

Authors:  Georges El Fakhri; Arkadiusz Sitek; Bastien Guérin; Marie Foley Kijewski; Marcelo F Di Carli; Stephen C Moore
Journal:  J Nucl Med       Date:  2005-08       Impact factor: 10.057

4.  Effect of maximal coronary vasodilation on transmural myocardial perfusion during tachycardia in the awake dog.

Authors:  R J Bache; F R Cobb
Journal:  Circ Res       Date:  1977-11       Impact factor: 17.367

5.  Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve.

Authors:  K L Gould; K Lipscomb; G W Hamilton
Journal:  Am J Cardiol       Date:  1974-01       Impact factor: 2.778

6.  Coronary flow reserve is reduced in young men with IDDM.

Authors:  O P Pitkänen; P Nuutila; O T Raitakari; T Rönnemaa; P J Koskinen; H Iida; T J Lehtimäki; H K Laine; T Takala; J S Viikari; J Knuuti
Journal:  Diabetes       Date:  1998-02       Impact factor: 9.461

7.  Use of wavelet transforms in analysis of time-activity data from cardiac PET.

Authors:  J W Lin; A F Laine; O Akinboboye; S R Bergmann
Journal:  J Nucl Med       Date:  2001-02       Impact factor: 10.057

8.  Consequences of using a simplified kinetic model for dynamic PET data.

Authors:  P G Coxson; R H Huesman; L Borland
Journal:  J Nucl Med       Date:  1997-04       Impact factor: 10.057

9.  Reduction of coronary flow reserve in areas with and without ischemia on stress perfusion imaging in patients with coronary artery disease: a study using oxygen 15-labeled water PET.

Authors:  Keiichiro Yoshinaga; Chietsugu Katoh; Kazuyuki Noriyasu; Yasuyoshi Iwado; Hideto Furuyama; Yoshinori Ito; Yuji Kuge; Tetsuro Kohya; Akira Kitabatake; Nagara Tamaki
Journal:  J Nucl Cardiol       Date:  2003 May-Jun       Impact factor: 5.952

10.  Modulating effect of regional myocardial performance on local myocardial perfusion in the dog.

Authors:  M Marzilli; S Goldstein; H N Sabbah; T Lee; P D Stein
Journal:  Circ Res       Date:  1979-11       Impact factor: 17.367

View more
  23 in total

Review 1.  Positron emission tomography in acute coronary syndromes.

Authors:  Leonarda Galiuto; Lazzaro Paraggio; Alberto R De Caterina; Elisa Fedele; Gabriella Locorotondo; Lucia Leccisotti; Alessandro Giordano; Antonio G Rebuzzi; Filippo Crea
Journal:  J Cardiovasc Transl Res       Date:  2011-12-15       Impact factor: 4.132

2.  Advances in clinical application of quantitative myocardial perfusion imaging.

Authors:  Juhani Knuuti; Antti Saraste
Journal:  J Nucl Cardiol       Date:  2012-08       Impact factor: 5.952

Review 3.  PET: Is myocardial flow quantification a clinical reality?

Authors:  Antti Saraste; Sami Kajander; Chunlei Han; Sergey V Nesterov; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

Review 4.  The clinical utility of assessing myocardial blood flow using positron emission tomography.

Authors:  Maria Cecilia Ziadi; Rob S B Beanlands
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 5.  Quantitative myocardial blood flow with Rubidium-82 PET: a clinical perspective.

Authors:  Christoffer E Hagemann; Adam A Ghotbi; Andreas Kjær; Philip Hasbak
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

Review 6.  Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

Authors:  Roberto Sciagrà; Alessandro Passeri; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Alessia Gimelli; Fabien Hyafil; Denis Agostini; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-02-05       Impact factor: 9.236

7.  Quantification of myocardial blood flow will reform the detection of CAD.

Authors:  Juhani Knuuti; Sami Kajander; Maija Mäki; Heikki Ukkonen
Journal:  J Nucl Cardiol       Date:  2009-06-03       Impact factor: 5.952

8.  Preserved coronary flow reserve effectively excludes high-risk coronary artery disease on angiography.

Authors:  Masanao Naya; Venkatesh L Murthy; Viviany R Taqueti; Courtney R Foster; Josh Klein; Mariya Garber; Sharmila Dorbala; Jon Hainer; Ron Blankstein; Frederick Resnic; Marcelo F Di Carli
Journal:  J Nucl Med       Date:  2014-01-09       Impact factor: 10.057

9.  Cardiac PET/CT for the evaluation of known or suspected coronary artery disease.

Authors:  Marcelo F Di Carli; Venkatesh L Murthy
Journal:  Radiographics       Date:  2011 Sep-Oct       Impact factor: 5.333

Review 10.  CFR and FFR assessment with PET and CTA: strengths and limitations.

Authors:  Ryo Nakazato; Ran Heo; Jonathon Leipsic; James K Min
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.