Literature DB >> 11216517

Quantification of myocardial perfusion in human subjects using 82Rb and wavelet-based noise reduction.

J W Lin1, R R Sciacca, R L Chou, A F Laine, S R Bergmann.   

Abstract

UNLABELLED: Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of flow estimates after the application of a novel multidimensional wavelet-based noise-reduction protocol.
METHODS: Myocardial perfusion was estimated using 82Rb and a two-compartment model from dynamic PET scans on 11 healthy volunteers at rest and after hyperemic stress with dipyridamole. Midventricular planes were divided into eight regions of interest, and a wavelet transform protocol was applied to images and time-activity curves. Flow estimates without and with the wavelet approach were compared with those obtained using H2(15)O.
RESULTS: Over a wide flow range (0.45-2.75 mL/g/min), flow achieved with the wavelet approach correlated extremely closely with values obtained with H2(15)O (y = 1.03 x -0.12; n = 23 studies, r = 0.94, P < 0.001). If the wavelet noise-reduction technique was not used, the correlation was less strong (y = 1.11 x + 0.24; n = 23 studies, r = 0.79, P < 0.001). In addition, the wavelet approach reduced the regional variation from 75% to 12% and from 62% to 11% (P < 0.001 for each comparison) for resting and stress studies, respectively.
CONCLUSION: The use of a wavelet protocol allows near-optimal noise reduction, markedly enhances the physiologic flow signal within the PET images, and enables accurate measurement of myocardial perfusion with 82Rb in human subjects over a wide range of flows.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11216517

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  24 in total

Review 1.  Tracer kinetic modeling in nuclear cardiology.

Authors:  T R DeGrado; S R Bergmann; C K Ng; D M Raffel
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

Review 2.  Myocardial perfusion imaging agents: SPECT and PET.

Authors:  George A Beller; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

3.  Improving low-dose blood-brain barrier permeability quantification using sparse high-dose induced prior for Patlak model.

Authors:  Ruogu Fang; Kolbeinn Karlsson; Tsuhan Chen; Pina C Sanelli
Journal:  Med Image Anal       Date:  2013-10-17       Impact factor: 8.545

Review 4.  Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Authors:  D Le Guludec; R Lautamäki; J Knuuti; J J Bax; F M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

5.  Assessment of myocardial perfusion by dynamic N-13 ammonia PET imaging: comparison of 2 tracer kinetic models.

Authors:  Aliasghar Khorsand; Senta Graf; Christian Pirich; Otto Muzik; Kurt Kletter; Robert Dudczak; Gerald Maurer; Heinz Sochor; Ernst Schuster; Gerold Porenta
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

6.  Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC.

Authors:  Venkatesh L Murthy; Timothy M Bateman; Rob S Beanlands; Daniel S Berman; Salvador Borges-Neto; Panithaya Chareonthaitawee; Manuel D Cerqueira; Robert A deKemp; E Gordon DePuey; Vasken Dilsizian; Sharmila Dorbala; Edward P Ficaro; Ernest V Garcia; Henry Gewirtz; Gary V Heller; Howard C Lewin; Saurabh Malhotra; April Mann; Terrence D Ruddy; Thomas H Schindler; Ronald G Schwartz; Piotr J Slomka; Prem Soman; Marcelo F Di Carli; Andrew Einstein; Raymond Russell; James R Corbett
Journal:  J Nucl Cardiol       Date:  2018-02       Impact factor: 5.952

7.  Quantification of myocardial blood flow with 82Rb positron emission tomography: clinical validation with 15O-water.

Authors:  John O Prior; Gilles Allenbach; Ines Valenta; Marek Kosinski; Cyrill Burger; Francis R Verdun; Angelika Bischof Delaloye; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-03-08       Impact factor: 9.236

8.  BMS-747158-02: a novel PET myocardial perfusion imaging agent.

Authors:  Ming Yu; Mary T Guaraldi; Mahesh Mistry; Mikhail Kagan; Jennifer L McDonald; Kenneth Drew; Heike Radeke; Michael Azure; Ajay Purohit; David S Casebier; Simon P Robinson
Journal:  J Nucl Cardiol       Date:  2007-10-22       Impact factor: 5.952

9.  Quantitative relationship between coronary vasodilator reserve assessed by 82Rb PET imaging and coronary artery stenosis severity.

Authors:  Constantinos Anagnostopoulos; Alexandra Almonacid; Georges El Fakhri; Zelmira Curillova; Arkadiusz Sitek; Michael Roughton; Sharmila Dorbala; Jeffrey J Popma; Marcelo F Di Carli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04-19       Impact factor: 9.236

10.  Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging.

Authors:  Karin Knešaurek; Josef Machac; Zhuangyu Zhang
Journal:  BMC Med Phys       Date:  2009-01-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.