Literature DB >> 17607038

Impact of myocardial perfusion imaging with PET and (82)Rb on downstream invasive procedure utilization, costs, and outcomes in coronary disease management.

Michael E Merhige1, William J Breen, Victoria Shelton, Teresa Houston, Brian J D'Arcy, Anthony F Perna.   

Abstract

UNLABELLED: We hypothesized that PET myocardial perfusion imaging with (82)Rb (PET MPI), would reduce downstream utilization of diagnostic arteriography, compared with SPECT, in patients matched for pretest likelihood of coronary disease (pCAD). PET MPI is more accurate for assessment of impaired coronary flow reserve compared with SPECT MPI, potentially reducing the demand for subsequent arteriography, percutaneous trans-coronary intervention, and coronary artery bypass grafting (CABG), with attendant cost savings, while avoiding a negative impact on coronary events.
METHODS: The frequency of diagnostic arteriography, revascularization, costs, and 1-y clinical outcomes in 2,159 patients studied with PET MPI was compared with 2 control groups studied with SPECT MPI matched to the PET group by pCAD: an internal control group of 102 patients and an external SPECT control group of 5,826 patients. CAD management costs were approximated with realistic global fee estimates.
RESULTS: Arteriography rates were 0.34 and 0.31 for the external and internal control SPECT groups and 0.13 for the patients studied with PET (P < 0.0001). pCAD averaged 0.39 in patients studied with PET MPI, and in the external SPECT control group, and 0.37 in the internal SPECT controls. Revascularization rates were 0.13 and 0.11 for external and internal SPECT patients and 0.06 for the PET group (P < 0.0001; P < 0.01), with a cost savings of 30% noted for PET patients, with no significant difference in cardiac death or myocardial infarction at 1-y follow-up.
CONCLUSION: PET MPI in patients with intermediate pCAD results in a >50% reduction in invasive coronary arteriography and CABG, a 30% cost savings, and excellent clinical outcomes at 1 y compared with SPECT.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17607038     DOI: 10.2967/jnumed.106.038323

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  33 in total

Review 1.  Myocardial perfusion scintigraphy: past, present and future.

Authors:  A Notghi; C S Low
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program.

Authors:  Ran Klein; Jennifer M Renaud; Maria C Ziadi; Stephanie L Thorn; Andy Adler; Rob S Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-04-13       Impact factor: 5.952

Review 3.  Quantification of myocardial blood flow and flow reserve: Technical aspects.

Authors:  Ran Klein; Rob S B Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

4.  Diagnosis and prognosis of coronary artery disease: PET is superior to SPECT: Pro.

Authors:  Rob S B Beanlands; George Youssef
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 5.  Quantitative myocardial blood flow with Rubidium-82 PET: a clinical perspective.

Authors:  Christoffer E Hagemann; Adam A Ghotbi; Andreas Kjær; Philip Hasbak
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

Review 6.  Facts and figures on CAD assessment with SPECT and PET-CT.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-02       Impact factor: 9.236

7.  Nuclear cardiology in the present and beyond: can we meet the challenges?

Authors:  Gary V Heller
Journal:  J Nucl Cardiol       Date:  2013-05-25       Impact factor: 5.952

Review 8.  Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Authors:  D Le Guludec; R Lautamäki; J Knuuti; J J Bax; F M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

9.  Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF.

Authors:  Sharmila Dorbala; Rory Hachamovitch; Zelmira Curillova; Deepak Thomas; Divya Vangala; Raymond Y Kwong; Marcelo F Di Carli
Journal:  JACC Cardiovasc Imaging       Date:  2009-07

10.  Synthesis and biodistribution of lipophilic and monocationic gallium radiopharmaceuticals derived from N,N'-bis(3-aminopropyl)-N,N'-dimethylethylenediamine: potential agents for PET myocardial imaging with 68Ga.

Authors:  Yui-May Hsiao; Carla J Mathias; Shiaw-Pyng Wey; Phillip E Fanwick; Mark A Green
Journal:  Nucl Med Biol       Date:  2009-01       Impact factor: 2.408

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.