| Literature DB >> 18405365 |
Christoph Becher1, Jan Springer, Sven Feil, Guiliano Cerulli, Hans H Paessler.
Abstract
BACKGROUND: Up to date, no information exists about the intra-articular temperature changes of the knee related to activity and ambient temperature.Entities:
Mesh:
Year: 2008 PMID: 18405365 PMCID: PMC2330048 DOI: 10.1186/1471-2474-9-46
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Figure 1Intra-articular insertion of the probe into the notch.
Figure 2Intra-articular temperatures measured before and during jogging and skiing activity over one hour. Significant increase of intra-articular temperatures was measured after 15, 30, 45 and 60 min in the jogging group. No significant changes were observed in the skiing group.
Figure 3Skin surface temperatures at the knee measured before and during jogging and skiing activity over one hour. Significant increase of the skin surface temperatures was measured after 15, 30, 45 and 60 min in the jogging group. No significant changes were observed in the skiing group.
Single leg hop test (Median (cm) min/max-range)
| Group | Pre_implantation | Post_implantation – pre_activity | Post_activity |
| Jogging | 119.5 (109.7/150.3) | 99.2 (91.2/107.4) | 115.7 (102.7/157.3) |
| Skiing | 124.5 (111.3/135.0) | 99.2 (90.1/102.3) | 130.0 (103.7/146.0) |
Implantation of the probe (post_implantation – pre activity) appeared to decrease the ability to perform the single leg hop test
KT 2000 (Median (mm) ± min/max-range)
| Group | Pre_implantation | Post_implantation – Pre_activity | Post_activity |
| Jogging | 9.0 (7.0/10.0) | 8.0 (7.0/10.0) | 8.5 (7.0/10.0) |
| Skiing | 9.5 (7.0/10.0) | 9.5 (7.0/10.0) | 10.0 (7.0/10.0) |
Joint laxity within the groups appeared not to be influenced by the implantation of the probe or the activity
Joint position sense (Mean difference between predetermined and reproduced angle ± SD)
| 30° | 60° | 90° | |
| Pre_implantation | |||
| Jogging | 5.0° ± 2.89° | 7.5° ± 3.8° | 5.8° ± 4.5° |
| Skiing | 5.0° ± 2.9° | 6.7° ± 3.7° | 4.2° ± 6.1° |
| Post_implantation – Pre_activity | |||
| Jogging | 11.7° ± 6.9° | 8.3° ± 3.7° | 9.2° ± 7.3° |
| Skiing | 7.5° ± 9.0° | 6.67° ± 3.73° | 8.83° ± 3.73° |
| Post-activity | |||
| Jogging | 6.7° ± 7.5° | 5.0° ± 4.1° | 7.5° ± 2.5° |
| Skiing | 3.3° ± 2.4° | 5.8° ± 1.9° | 7.5° ± 3.8° |
Implantation of the probe (post_implantation – pre activity) appeared to decrease the joint position sense