Literature DB >> 18403289

A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis.

Matthew A Schiefer1, Ronald J Triolo, Dustin J Tyler.   

Abstract

Functional electrical stimulation (FES) can restore limb movements through electrically initiated, coordinated contractions of paralyzed muscles. The peripheral nerve is an attractive site for stimulation using cuff electrodes. Many applications will require the electrode to selectively activate many smaller populations of axons within a common nerve trunk. The purpose of this study is to computationally model the performance of a flat interface nerve electrode (FINE) on the proximal femoral nerve for standing and stepping applications. Simulations investigated multiple FINE configurations to determine the optimal number and locations of contacts for the maximum muscular selectivity. Realistic finite element method (FEM) models were developed from digitized cross sections from cadaver femoral nerve specimens. Electrical potentials were calculated and interpolated voltages were applied to a double-cable axon model. Model output was analyzed to determine selectivity and estimate joint moments with a musculoskeletal model. Simulations indicated that a 22-contact FINE will produce the greatest selectivity. Simulations predicted that an eight-contact FINE can be expected to selectively stimulate each of the six muscles innervated by the proximal femoral nerve, producing a sufficient knee extension moment for the sit-to-stand transition and contributing 60% of the hip flexion moment needed during gait. We conclude that, whereas more contacts produce greater selectivity, eight channels are sufficient for standing and stepping with an FES system using a FINE on the common femoral nerve.

Entities:  

Mesh:

Year:  2008        PMID: 18403289      PMCID: PMC2920206          DOI: 10.1109/TNSRE.2008.918425

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  28 in total

Review 1.  Motor unit physiology: some unresolved issues.

Authors:  R M Enoka; A J Fuglevand
Journal:  Muscle Nerve       Date:  2001-01       Impact factor: 3.217

2.  Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis.

Authors:  A Q Choi; J K Cavanaugh; D M Durand
Journal:  IEEE Trans Biomed Eng       Date:  2001-02       Impact factor: 4.538

3.  The use of selective electrical stimulation of the quadriceps to improve standing function in paraplegia.

Authors:  J P Uhlir; R J Triolo; R Kobetic
Journal:  IEEE Trans Rehabil Eng       Date:  2000-12

4.  Effects of stimulated hip extension moment and position on upper-limb support forces during FNS-induced standing--a technical note.

Authors:  R Triolo; M Wibowo; J Uhlir; R Kobetic; R Kirsch
Journal:  J Rehabil Res Dev       Date:  2001 Sep-Oct

5.  Modelling the effects of electric fields on nerve fibres: influence of the myelin sheath.

Authors:  A G Richardson; C C McIntyre; W M Grill
Journal:  Med Biol Eng Comput       Date:  2000-07       Impact factor: 2.602

6.  Functionally selective peripheral nerve stimulation with a flat interface nerve electrode.

Authors:  Dustin J Tyler; Dominique M Durand
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2002-12       Impact factor: 3.802

7.  Sources and effects of electrode impedance during deep brain stimulation.

Authors:  Christopher R Butson; Christopher B Maks; Cameron C McIntyre
Journal:  Clin Neurophysiol       Date:  2005-12-22       Impact factor: 3.708

8.  Computational analysis of subthalamic nucleus and lenticular fasciculus activation during therapeutic deep brain stimulation.

Authors:  Svjetlana Miocinovic; Martin Parent; Christopher R Butson; Philip J Hahn; Gary S Russo; Jerrold L Vitek; Cameron C McIntyre
Journal:  J Neurophysiol       Date:  2006-05-31       Impact factor: 2.714

9.  Modeling the excitability of mammalian nerve fibers: influence of afterpotentials on the recovery cycle.

Authors:  Cameron C McIntyre; Andrew G Richardson; Warren M Grill
Journal:  J Neurophysiol       Date:  2002-02       Impact factor: 2.714

10.  Recent demographic and injury trends in people served by the Model Spinal Cord Injury Care Systems.

Authors:  A I Nobunaga; B K Go; R B Karunas
Journal:  Arch Phys Med Rehabil       Date:  1999-11       Impact factor: 3.966

View more
  38 in total

Review 1.  Neural interfaces for somatosensory feedback: bringing life to a prosthesis.

Authors:  Dustin J Tyler
Journal:  Curr Opin Neurol       Date:  2015-12       Impact factor: 5.710

2.  On the parameters used in finite element modeling of compound peripheral nerves.

Authors:  Nicole A Pelot; Christina E Behrend; Warren M Grill
Journal:  J Neural Eng       Date:  2018-12-03       Impact factor: 5.379

3.  Model-based Vestibular Afferent Stimulation: Modular Workflow for Analyzing Stimulation Scenarios in Patient Specific and Statistical Vestibular Anatomy.

Authors:  Michael Handler; Peter P Schier; Karl D Fritscher; Patrik Raudaschl; Lejo Johnson Chacko; Rudolf Glueckert; Rami Saba; Rainer Schubert; Daniel Baumgarten; Christian Baumgartner
Journal:  Front Neurosci       Date:  2017-12-19       Impact factor: 4.677

4.  Predicting myelinated axon activation using spatial characteristics of the extracellular field.

Authors:  E J Peterson; O Izad; D J Tyler
Journal:  J Neural Eng       Date:  2011-07-13       Impact factor: 5.379

5.  Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.

Authors:  Daniel W Tan; Matthew A Schiefer; Michael W Keith; J Robert Anderson; Dustin J Tyler
Journal:  J Neural Eng       Date:  2015-01-28       Impact factor: 5.379

6.  Model study of combined electrical and near-infrared neural stimulation on the bullfrog sciatic nerve.

Authors:  Mengxian You; Zongxia Mou
Journal:  Lasers Med Sci       Date:  2017-05-06       Impact factor: 3.161

7.  Fascicular perineurium thickness, size, and position affect model predictions of neural excitation.

Authors:  Yanina Grinberg; Matthew A Schiefer; Dustin J Tyler; Kenneth J Gustafson
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-12       Impact factor: 3.802

8.  Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk.

Authors:  K H Polasek; M A Schiefer; G C J Pinault; R J Triolo; D J Tyler
Journal:  J Neural Eng       Date:  2009-11-09       Impact factor: 5.379

9.  Intraoperative demonstration of selective stimulation of the common human femoral nerve with a FINE.

Authors:  Matthew A Schiefer; Katharine H Polasek; Ronald J Triolo; Gilles C Pinault; Dustin J Tyler
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

10.  Nerve cuff stimulation and the effect of fascicular organization for hand grasp in nonhuman primates.

Authors:  N Brill; K Polasek; E Oby; C Ethier; L Miller; D Tyler
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.