Literature DB >> 11732832

Effects of stimulated hip extension moment and position on upper-limb support forces during FNS-induced standing--a technical note.

R Triolo1, M Wibowo, J Uhlir, R Kobetic, R Kirsch.   

Abstract

This study explores the effects of active hip extension moment produced by electrical stimulation on the support forces the arms must exert through an assistive device during quiet erect standing with functional neuromuscular stimulation (FNS) in individuals with spinal cord injuries (SCI). A static sagittal plane biomechanical model of human standing was developed to predict the effects of stimulated hip extension moment and sagittal plane hip angle on the arm support necessary to maintain an upright posture. Two individuals with complete thoracic SCI were then tested while they stood with continuous stimulation to the knee and trunk extensors. The steady-state active extension moment exerted at the hip was varied by activating different combinations of hip extensor muscles with continuous stimulation while steady-state support forces applied to the arms and feet during standing were measured. The steady-state support forces imposed on the arms during quiet standing decrease with increased stimulated hip extension moment and are highly dependent upon hip flexion angle, as predicted by the biomechanical simulations. Experimentally, the combination of gluteus maximus and semimembranosus stimulation produced three times more steady-state hip extension moment than did stimulation of the gluteus maximus and adductor magnus. This resulted in a ten-fold decrease in body weight supported on the arms. More vertical postures (smaller hip flexion angles) improve the effectiveness of the hip extensor muscles in reducing the support forces placed on the arms. A single Newton-meter of stimulated hip extension moment with the hips fixed at 5 degrees of flexion results in almost five times the reduction in arm support forces as with the hips at 20 degrees. To minimize the forces applied by the arms on an assistive device for support while standing with FNS, these preliminary results suggest that (1) efforts should be made to assume the most erect postures possible and (2) muscles and stimulation paradigms that maximize active hip extension moment should be chosen.

Entities:  

Mesh:

Year:  2001        PMID: 11732832

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  5 in total

1.  A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis.

Authors:  Matthew A Schiefer; Ronald J Triolo; Dustin J Tyler
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-04       Impact factor: 3.802

2.  Selective stimulation of the human femoral nerve with a flat interface nerve electrode.

Authors:  M A Schiefer; K H Polasek; R J Triolo; G C J Pinault; D J Tyler
Journal:  J Neural Eng       Date:  2010-03-08       Impact factor: 5.379

3.  Design and evaluation of a stand-up motorized prone cart.

Authors:  Jeffrey J Harrow; Pascal Malassigné; Audrey L Nelson; Robert P Jensen; Margaret Amato; Polly L Palacios
Journal:  J Spinal Cord Med       Date:  2007       Impact factor: 1.985

4.  Intraoperative demonstration of selective stimulation of the common human femoral nerve with a FINE.

Authors:  Matthew A Schiefer; Katharine H Polasek; Ronald J Triolo; Gilles C Pinault; Dustin J Tyler
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

5.  Fascicular anatomy of human femoral nerve: implications for neural prostheses using nerve cuff electrodes.

Authors:  Kenneth J Gustafson; Gilles C J Pinault; Jennifer J Neville; Ishaq Syed; John A Davis; Jesse Jean-Claude; Ronald J Triolo
Journal:  J Rehabil Res Dev       Date:  2009
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.