Literature DB >> 18396032

Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies.

Kevin A Heyries1, Michael G Loughran, Daniel Hoffmann, Alexandra Homsy, Loïc J Blum, Christophe A Marquette.   

Abstract

Protein microarrays for allergen-specific antibodies detection were integrated in microfluidic chips, with imaging chemiluminescence as the analytical technique. This paper demonstrates the feasibility of miniaturized chemiluminescent ELISA by presenting rapid, reproducible and sensitive detection of protein antibodies using microfluidics. Three different proteins, beta-lactoglobulin, peanut lectin and human IgG were immobilized via a "macromolecules to polydimethylsiloxane elastomer (PDMS) transfer" protocol and used as capturing agent for the detection of specific antibodies. A convenient and reversible procedure was used to bond the PDMS microarray substrate to complimentary SU-8/glass microfluidic reaction chambers. The hydrodynamic behaviours of the three proteins interactions within the micro-chambers were investigated to select the most efficient flowing parameters (come to terms with the assay time and performances). The use of optimized conditions led to the concomitant detection of three specific antibodies at pM level in 300 microL and using 6 min sample incubation time. Finally, sera from allergic patients were assayed using the microfluidic device modified with apple hazelnut and pollen allergen. The results obtained compared favourably with those obtained with the classical Pharmacia CAP system.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18396032     DOI: 10.1016/j.bios.2008.02.025

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  14 in total

1.  Thiolene-based microfluidic flow cells for surface plasmon resonance imaging.

Authors:  Gareth Sheppard; Takao Oseki; Akira Baba; Derek Patton; Futao Kaneko; Leidong Mao; Jason Locklin
Journal:  Biomicrofluidics       Date:  2011-06-07       Impact factor: 2.800

Review 2.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

Review 3.  Microarrayed allergen molecules for the diagnosis of allergic diseases.

Authors:  Adriano Mari; Claudia Alessandri; Maria Livia Bernardi; Rosetta Ferrara; Enrico Scala; Danila Zennaro
Journal:  Curr Allergy Asthma Rep       Date:  2010-09       Impact factor: 4.806

4.  IgE allergy diagnostics and other relevant tests in allergy, a World Allergy Organization position paper.

Authors:  Ignacio J Ansotegui; Giovanni Melioli; Giorgio Walter Canonica; Luis Caraballo; Elisa Villa; Motohiro Ebisawa; Giovanni Passalacqua; Eleonora Savi; Didier Ebo; R Maximiliano Gómez; Olga Luengo Sánchez; John J Oppenheimer; Erika Jensen-Jarolim; David A Fischer; Tari Haahtela; Martti Antila; Jean J Bousquet; Victoria Cardona; Wen Chin Chiang; Pascal M Demoly; Lawrence M DuBuske; Marta Ferrer Puga; Roy Gerth van Wijk; Sandra Nora González Díaz; Alexei Gonzalez-Estrada; Edgardo Jares; Ayse Füsun Kalpaklioğlu; Luciana Kase Tanno; Marek L Kowalski; Dennis K Ledford; Olga Patricia Monge Ortega; Mário Morais Almeida; Oliver Pfaar; Lars K Poulsen; Ruby Pawankar; Harald E Renz; Antonino G Romano; Nelson A Rosário Filho; Lanny Rosenwasser; Mario A Sánchez Borges; Enrico Scala; Gian-Enrico Senna; Juan Carlos Sisul; Mimi L K Tang; Bernard Yu-Hor Thong; Rudolf Valenta; Robert A Wood; Torsten Zuberbier
Journal:  World Allergy Organ J       Date:  2020-02-25       Impact factor: 4.084

5.  Microfluidic LIPS for serum antibody detection: demonstration of a rapid test for HSV-2 infection.

Authors:  Adnan Zubair; Peter D Burbelo; Ludovic G Vincent; Michael J Iadarola; Paul D Smith; Nicole Y Morgan
Journal:  Biomed Microdevices       Date:  2011-12       Impact factor: 2.838

6.  Heterogeneous immunoassays in microfluidic format using fluorescence detection with integrated amorphous silicon photodiodes.

Authors:  A T Pereira; P Novo; D M F Prazeres; V Chu; J P Conde
Journal:  Biomicrofluidics       Date:  2011-02-15       Impact factor: 2.800

Review 7.  Microfluidic methods for precision diagnostics in food allergy.

Authors:  Nicolas Castaño; Seth C Cordts; Kari C Nadeau; Mindy Tsai; Stephen J Galli; Sindy K Y Tang
Journal:  Biomicrofluidics       Date:  2020-04-03       Impact factor: 2.800

8.  Effects of sample delivery on analyte capture in porous bead sensors.

Authors:  Jie Chou; Luanyi E Li; Eliona Kulla; Nicolaos Christodoulides; Pierre N Floriano; John T McDevitt
Journal:  Lab Chip       Date:  2012-12-21       Impact factor: 6.799

Review 9.  Microfluidic immunoassay for detection of serological antibodies: A potential tool for rapid evaluation of immunity against SARS-CoV-2.

Authors:  Hogi Hartanto; Minghui Wu; Miu Ling Lam; Ting-Hsuan Chen
Journal:  Biomicrofluidics       Date:  2020-12-14       Impact factor: 2.800

Review 10.  Microarray technology for major chemical contaminants analysis in food: current status and prospects.

Authors:  Zhaowei Zhang; Peiwu Li; Xiaofeng Hu; Qi Zhang; Xiaoxia Ding; Wen Zhang
Journal:  Sensors (Basel)       Date:  2012-07-04       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.