Literature DB >> 23117481

Effects of sample delivery on analyte capture in porous bead sensors.

Jie Chou1, Luanyi E Li, Eliona Kulla, Nicolaos Christodoulides, Pierre N Floriano, John T McDevitt.   

Abstract

Sample delivery is a crucial aspect of point-of-care applications where sample volumes need to be low and assay times short, while providing high analytical and clinical sensitivity. In this paper, we explore the influence of the factors surrounding sample delivery on analyte capture in an immunoassay-based sensor array manifold of porous beads resting in individual wells. We model using computational fluid dynamics and a flow-through device containing beads sensitized specifically to C-reactive protein (CRP) to explore the effects of volume of sample, rate of sample delivery, and use of recirculation vs. unilateral delivery on the effectiveness of the capture of CRP on and within the porous bead sensor. Rate of sample delivery lends to the development of a time-dependent, shrinking depletion region around the bead exterior. Our findings reveal that at significantly high rates of delivery, unique to porous bead substrates, capture at the rim of the bead is reaction-limited, while capture in the interior of the bead is transport-limited. While the fluorescence signal results from the aggregate of captured material throughout the bead, multiple kinetic regimes exist within the bead. Further, under constant pressure conditions dictated by the array architecture, we reveal the existence of an optimal flow rate that generates the highest signal, under point-of-care constraints of limited-volume and limited-time. When high sensitivity is needed, recirculation can be implemented to overcome the analyte capture limitations due to volume and time constraints. Computational simulations agree with experimental results performed under similar conditions.

Entities:  

Mesh:

Year:  2012        PMID: 23117481      PMCID: PMC3541674          DOI: 10.1039/c2lc40752c

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  38 in total

Review 1.  Microfluidic technologies in clinical diagnostics.

Authors:  Thomas H Schulte; Ron L Bardell; Bernhard H Weigl
Journal:  Clin Chim Acta       Date:  2002-07       Impact factor: 3.786

Review 2.  Physics and applications of microfluidics in biology.

Authors:  David J Beebe; Glennys A Mensing; Glenn M Walker
Journal:  Annu Rev Biomed Eng       Date:  2002-03-22       Impact factor: 9.590

Review 3.  Micro total analysis systems. Recent developments.

Authors:  Torsten Vilkner; Dirk Janasek; Andreas Manz
Journal:  Anal Chem       Date:  2004-06-15       Impact factor: 6.986

Review 4.  Commercialization of microfluidic point-of-care diagnostic devices.

Authors:  Curtis D Chin; Vincent Linder; Samuel K Sia
Journal:  Lab Chip       Date:  2012-02-17       Impact factor: 6.799

Review 5.  Lab-on-a-chip devices for global health: past studies and future opportunities.

Authors:  Curtis D Chin; Vincent Linder; Samuel K Sia
Journal:  Lab Chip       Date:  2006-10-27       Impact factor: 6.799

6.  Novel dome-shaped structures for high-efficiency patterning of individual microbeads in a microfluidic device.

Authors:  Chee Tiong Lim; Yong Zhang
Journal:  Small       Date:  2007-04       Impact factor: 13.281

7.  A spatially addressable bead-based biosensor for simple and rapid DNA detection.

Authors:  Johnson K Ng; Ezrein S Selamat; Wen-Tso Liu
Journal:  Biosens Bioelectron       Date:  2007-09-12       Impact factor: 10.618

Review 8.  Microfluidic platforms for lab-on-a-chip applications.

Authors:  Stefan Haeberle; Roland Zengerle
Journal:  Lab Chip       Date:  2007-07-27       Impact factor: 6.799

Review 9.  Biomedical applications of protein microarrays.

Authors:  Sándor Spisák; András Guttman
Journal:  Curr Med Chem       Date:  2009       Impact factor: 4.530

10.  Modeling analyte transport and capture in porous bead sensors.

Authors:  Jie Chou; Alexis Lennart; Jorge Wong; Mehnaaz F Ali; Pierre N Floriano; Nicolaos Christodoulides; James Camp; John T McDevitt
Journal:  Anal Chem       Date:  2012-02-09       Impact factor: 6.986

View more
  5 in total

1.  Programmable bio-nano-chip system: a flexible point-of-care platform for bioscience and clinical measurements.

Authors:  Michael P McRae; Glennon W Simmons; Jorge Wong; Basil Shadfan; Sanjiv Gopalkrishnan; Nicolaos Christodoulides; John T McDevitt
Journal:  Lab Chip       Date:  2015-08-26       Impact factor: 6.799

2.  Real-time Detection of Breast Cancer Cells Using Peptide-functionalized Microcantilever Arrays.

Authors:  Hashem Etayash; Keren Jiang; Sarfuddin Azmi; Thomas Thundat; Kamaljit Kaur
Journal:  Sci Rep       Date:  2015-10-05       Impact factor: 4.379

3.  3D Printing of Elastic Membranes for Fluidic Pumping and Demonstration of Reciprocation Inserts on the Microfluidic Disc.

Authors:  Maria Bauer; Adrian Bahani; Tracy Ogata; Marc Madou
Journal:  Micromachines (Basel)       Date:  2019-08-19       Impact factor: 2.891

Review 4.  Porous bead-based diagnostic platforms: bridging the gaps in healthcare.

Authors:  Jie Chou; Jorge Wong; Nicolaos Christodoulides; Pierre N Floriano; Ximena Sanchez; John McDevitt
Journal:  Sensors (Basel)       Date:  2012-11-09       Impact factor: 3.576

5.  Miniaturized Platform for Individual Coral Polyps Culture and Monitoring.

Authors:  Yongsheng Luo; Jinglun Zhao; Chunpeng He; Zuhong Lu; Xiaolin Lu
Journal:  Micromachines (Basel)       Date:  2020-01-23       Impact factor: 2.891

  5 in total