Literature DB >> 18395212

Structural simulations of prosthetic tri-leaflet aortic heart valves.

Rami Haj-Ali1, Lakshmi P Dasi, Hee-Sun Kim, Joonho Choi, H W Leo, Ajit P Yoganathan.   

Abstract

This study presents a combined computational and experimental approach for the nonlinear structural simulations of polymeric tri-leaflet aortic valves (PAVs). Nonlinear shell-based and quasi-static finite-element (FE) structural models are generated for a prosthetic valve geometry that includes the leaflets, stents and root materials, such as the bottom base and outside walls. The PAV structural model is subject to an ensemble averaged transvalvular pressure waveform measured from repeated in vitro tests conducted with a left heart simulator. High-resolution optical measurements are used to measure the in vitro kinematics of the leaflets and the stents. Qualitative and quantitative deformation measures are defined in order to compare the predicted kinematics from the PAV models with the in vitro measurements. Six new quantitative deformation metrics are introduced. They include three distances measuring the current PAV geometric center to the leaflet edges while additional three distances define the stent post-to-stent post (SPTSP) distances. The structural model is able to predict the kinematic deformation metrics with maximum errors around 10% especially in systole where the displacements are larger in magnitude. The combined structural modeling with experimental simulations along with the new proposed deformation metrics provide an effective way to study the PAV structural behavior and a path for improving the structural design of prosthetic valves.

Entities:  

Mesh:

Year:  2008        PMID: 18395212     DOI: 10.1016/j.jbiomech.2008.02.026

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  11 in total

1.  A fluid-structure interaction model of the aortic valve with coaptation and compliant aortic root.

Authors:  Gil Marom; Rami Haj-Ali; Ehud Raanani; Hans-Joachim Schäfers; Moshe Rosenfeld
Journal:  Med Biol Eng Comput       Date:  2011-12-15       Impact factor: 2.602

2.  A parametric study on mathematical formulation and geometrical construction of a stentless aortic heart valve.

Authors:  Esfandyar Kouhi; Yosry S Morsi
Journal:  J Artif Organs       Date:  2013-06-30       Impact factor: 1.731

3.  An optical method for evaluation of geometric fidelity for anatomically shaped tissue-engineered constructs.

Authors:  Jeffrey J Ballyns; Daniel L Cohen; Evan Malone; Suzanne A Maher; Hollis G Potter; Timothy Wright; Hod Lipson; Lawrence J Bonassar
Journal:  Tissue Eng Part C Methods       Date:  2010-08       Impact factor: 3.056

4.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

5.  Numerical Approximation of Elasticity Tensor Associated With Green-Naghdi Rate.

Authors:  Haofei Liu; Wei Sun
Journal:  J Biomech Eng       Date:  2017-08-01       Impact factor: 2.097

6.  Design and validation of a novel bioreactor to subject aortic valve leaflets to side-specific shear stress.

Authors:  Ling Sun; Nalini M Rajamannan; Philippe Sucosky
Journal:  Ann Biomed Eng       Date:  2011-04-01       Impact factor: 3.934

7.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment.

Authors:  Qian Wang; Eric Sirois; Wei Sun
Journal:  J Biomech       Date:  2012-06-13       Impact factor: 2.712

8.  Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage.

Authors:  Karin Lavon; Gil Marom; Matteo Bianchi; Rotem Halevi; Ashraf Hamdan; Adi Morany; Ehud Raanani; Danny Bluestein; Rami Haj-Ali
Journal:  Med Biol Eng Comput       Date:  2019-08-01       Impact factor: 2.602

9.  Hemodynamic and thrombogenic analysis of a trileaflet polymeric valve using a fluid-structure interaction approach.

Authors:  Filippo Piatti; Francesco Sturla; Gil Marom; Jawaad Sheriff; Thomas E Claiborne; Marvin J Slepian; Alberto Redaelli; Danny Bluestein
Journal:  J Biomech       Date:  2015-08-21       Impact factor: 2.712

Review 10.  Image-guided tissue engineering.

Authors:  Jeffrey J Ballyns; Lawrence J Bonassar
Journal:  J Cell Mol Med       Date:  2009-07-06       Impact factor: 5.310

View more