Literature DB >> 18384399

Immediate and early loading of oxidized tapered implants in the partially edentulous maxilla: a 1-year prospective clinical, radiographic, and resonance frequency analysis study.

Kerstin Fischer1, Mats Bäckström, Lars Sennerby.   

Abstract

BACKGROUND: The use of immediate/early implant loading protocols offers obvious advantages for the patient. Although well documented in the totally edentulous mandible, information about clinical outcomes from such protocols in the partially edentate maxilla is lacking.
PURPOSE: The present study was conducted to clinically and radiographically evaluate a tapered implant design with an oxidized surface for immediate/early loading in the partially edentulous maxilla. The aim was also to correlate implant stability measurements using resonance frequency analysis (RFA) with implant diameter and length, bone quality and quantity, and marginal bone levels and marginal bone loss.
MATERIALS AND METHODS: A total of 32 patients with a need of implant treatment in their partially edentulous maxilla were included in the study. A total of 53 Replace Select TiUnite implants (Nobel Biocare AB, Göteborg, Sweden) were used in the study; 16 for single tooth replacements in 16 patients and 37 implants for partial bridges in another 16 patients. The single tooth replacements were loaded the same day with a temporary crown, while permanent partial bridges were delivered within 16 days. Intraoral radiographs were taken at surgery and after 1 year for marginal bone measurements. RFA measurements were performed at baseline and after 3, 6, and 12 months.
RESULTS: One implant used for a single tooth replacement failed, giving an overall survival rate of 98.1% after 1 year. On average, 1.1 mm (SD 1.0) bone was lost during 1 year; 1.5 mm (SD 1.0) in single tooth and 0.9 mm (SD 1.0) in partial cases. The implant stability increased with time from 63.3 implant stability quotient (ISQ) (SD 6.1) at baseline to 64.3 (SD 5.3), 65.0 (SD 4.6), and 66.8 (SD 5.6) after 3, 6, and 12 months, respectively. The average change from baseline to 1 year was 3.3 ISQ (SD 5.0) and was statistically significant (p < .05). There was no difference between single and partial cases. Implant stability correlated with bone quantity and quality at implant sites, but not with marginal bone level measurements.
CONCLUSIONS: It is concluded that immediate/early loading can be used in the partially edentulous maxilla with good clinical and radiographic short-term outcomes. Implant stability at placement correlated with bone quantity and quality, and increased with time as measured with RFA, indicating a favorable bone tissue response to the loaded implants. Any correlations between RFA and marginal bone level measurements were not observed in the present study.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18384399     DOI: 10.1111/j.1708-8208.2008.00096.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  8 in total

1.  Comparative study of immediate functional loading and immediate non-functional loading of monocortical implants.

Authors:  J P Singh; A K Gupta; R K Dhiman; S K Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2014-03-12

2.  Predictive values of resonance frequency analysis as a diagnostic tool in palatal implant loss.

Authors:  Katja Wieczorek; Winfried Harzer; Heinrich Wehrbein; Maximilian Moergel; Martin Kunkel; Britta A Jung
Journal:  Angle Orthod       Date:  2019-03-18       Impact factor: 2.079

3.  A comparative analysis of periimplant bone levels of immediate and conventionally loaded implants.

Authors:  G K Thapliyal; V R Pawar
Journal:  Med J Armed Forces India       Date:  2012-09-14

4.  Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study.

Authors:  Frederico Santos Lages; Dhelfeson Willya Douglas-de-Oliveira; Guilherme Siqueira Ibelli; Fatimah Assaf; Thallita Pereira Queiroz; Fernando Oliveira Costa
Journal:  PLoS One       Date:  2017-07-24       Impact factor: 3.240

5.  Clinical evaluation of the stability of implants placed at different supracrestal levels.

Authors:  B Alper Gultekin; Ali Sirali; Pinar Gultekin; Selim Ersanli
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

6.  Three-dimensional descriptive study of the pterygomaxillary region related to pterygoid implants: A retrospective study.

Authors:  Carmen Salinas-Goodier; Rosa Rojo; Jorge Murillo-González; Juan Carlos Prados-Frutos
Journal:  Sci Rep       Date:  2019-11-07       Impact factor: 4.379

7.  Early loading of hydrophilic titanium implants inserted in low-mineralized (D3 and D4) bone: one year results of a prospective clinical trial.

Authors:  Uwe Held; Dennis Rohner; Daniel Rothamel
Journal:  Head Face Med       Date:  2013-12-09       Impact factor: 2.151

8.  Preoperative evaluation of bone quality for dental implantation using an ultrasound axial transmission device in an ex vivo model.

Authors:  Shinsuke Okada; Akira Kawano; Hiroshi Oue; Yosuke Takeda; Miyuki Yokoi; Katsunori Koretake; Kazuhiro Tsuga
Journal:  Clin Exp Dent Res       Date:  2017-06-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.