Literature DB >> 18379021

A novel method for comparing 3D target volume delineations in radiotherapy.

R W van der Put1, B W Raaymakers, E M Kerkhof, M van Vulpen, J J W Lagendijk.   

Abstract

When comparing delineations it is often useful to obtain a local measure of distance between the volume surfaces. Commonly used methods for analysing local distance exhibit fundamental drawbacks which may cause overestimation of the distance or lead to asymmetry in the measure. This paper describes a new method that aims to solve these problems. The new method finds corresponding points between two delineations by traversing a vector field based on the combined gradient of the distance transforms. The proposed method provides a fundamentally more reliable, symmetric measure of distance. This is supported by an illustrative example of observer variation in prostate delineation. An implementation of the method is available on request to the author.

Entities:  

Mesh:

Year:  2008        PMID: 18379021     DOI: 10.1088/0031-9155/53/8/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes.

Authors:  R Jena; N F Kirkby; K E Burton; A C F Hoole; L T Tan; N G Burnet
Journal:  Br J Radiol       Date:  2009-07-20       Impact factor: 3.039

2.  Automatic segmentation of whole breast using atlas approach and deformable image registration.

Authors:  Valerie K Reed; Wendy A Woodward; Lifei Zhang; Eric A Strom; George H Perkins; Welela Tereffe; Julia L Oh; T Kuan Yu; Isabelle Bedrosian; Gary J Whitman; Thomas A Buchholz; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-17       Impact factor: 7.038

3.  Bidirectional local distance measure for comparing segmentations.

Authors:  Hak Soo Kim; Samuel B Park; Simon S Lo; James I Monroe; Jason W Sohn
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

Authors:  Kishor Karki; Siddharth Saraiya; Geoffrey D Hugo; Nitai Mukhopadhyay; Nuzhat Jan; Jessica Schuster; Matthew Schutzer; Lester Fahrner; Robert Groves; Kathryn M Olsen; John C Ford; Elisabeth Weiss
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-05-06       Impact factor: 7.038

5.  Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy.

Authors:  Seyed Mehdi Bagherimofidi; Claus Chunli Yang; Roberto Rey-Dios; Madhava R Kanakamedala; Ali Fatemi
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-19

6.  Distance deviation measure of contouring variability.

Authors:  Peter Rogelj; Robert Hudej; Primoz Petric
Journal:  Radiol Oncol       Date:  2013-02-01       Impact factor: 2.991

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.